LG LW1822IVSM AIR CONDITIONER Owner’s Manual
- June 5, 2024
- LG
Table of Contents
- LG LW1822IVSM AIR CONDITIONER
- IMPORTANT SAFETY INSTRUCTIONS
- MAINTENANCE
- REFRIGERANT (FOR R32 ONLY)
- PRODUCT OVERVIEW
- INSTALLATION
- Parts Included (Appearance May Vary)
- Unit Installation
- OPERATION
- FCC Notice
- MAINTENANCE
- TROUBLESHOOTING
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LG LW1822IVSM AIR CONDITIONER
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important. We have provided many
important safety messages in this manual and on your appliance. Always read
and follow all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or injure you and others. All safety messages will follow the safety alert symbol and either the word WARNING or CAUTION. These words mean:
WARNING
You may be killed or seriously injured if you do not follow instructions.
CAUTION
You may be injured or cause damage to the product if you do not follow instructions. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what may happen if the instructions are not followed. The following symbols are displayed on units.
- This symbol indicates that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposure to an external ignition source, there is a risk of fire.
- This symbol indicates that the Operation Manual should be read carefully.
- This symbol indicates that a service personnel should be handling this equipment with reference to the Installation Manual.
- This symbol indicates that information is available such as the Operating Manual or Installation Manual.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of explosion, fire, death, electric shock, scalding or
injury to persons when using this product, follow basic precautions, including
the following:
INSTALLATION
- Before use, the appliance must be properly installed as described in this manual.
- Contact the authorized service technician for repair or maintenance of this unit.
- Contact the installer for installation of this unit.
- Young children should be supervised to ensure that they do not play with the air conditioner.
- When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.
- Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.
- Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
- Always plug into a grounded outlet.
- Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
- When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
- Plug in the power plug properly.
- Do not modify or extend the power cord.
- Do not start/stop operation by plugging/unplugging the power cord.
- If the cord/plug is damaged, have it replaced by an authorized service person using authorized replacement parts.
- Use a dedicated circuit.
- Do not disassemble or modify the product.
- Adhere to all industry-recommended safety procedures including the use of long-sleeved gloves and safety glasses.
- Disconnect the power cord or circuit breaker before installing or servicing the appliance.
- Keep packaging materials out of the reach of children. These materials can pose a suffocation risk to children.
- Store and install the product where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
OPERATION
- Use this appliance only for its intended purpose.
- Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled, or has missing or broken parts, including a damaged cord or plug.
- Repair or immediately replace all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.
- Do not run cord under carpets or mats where it could be stepped on and damaged.
- Keep the cord out from under heavy objects like tables or chairs.
- Do not place the power cord near a heat source.
- Do not use an adaptor or plug the product into a shared outlet.
- Do not tamper with controls.
- If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance, unplug it immediately, and contact the LG Electronics Customer Information Center.
- Never unplug the appliance by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet.
- Do not grasp the power cord or touch the appliance controls with wet hands.
- If water enters the product, turn off the power at the main circuit, then unplug the product and call for service.
- If the product has been submerged, contact the LG Electronics Customer Information Center for instructions before resuming use.
- Unplug the product when unused for long periods.
- Unplug the product before cleaning.
- In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a window or door to ventilate the area immediately.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- The interior of the product must only be cleaned by an authorized service center or a dealer.
- Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage, product failure, electrical shock, or fire.
GROUNDING INSTRUCTIONS
- The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER PLUG.
- Situations when the appliance will be disconnected occasionally; Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores. The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection.
- Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded through the house wiring. The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
- Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter ground terminal might break. Do not use the appliance with a broken adapter plug.
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these situations. Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet instead.
CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or
damage to the product or property when using this product, follow basic
precautions, including the following:
INSTALLATION
- Take care when installing the product that exhaust or condensation does not damage nearby property.
- Follow installation instructions exactly to avoid excessive vibration or water leakage.
- Wear gloves and use caution when unpacking and installing the appliance. Screws or sharp edges can cause injuries.
OPERATION
- This appliance is not intended for use as a precision refrigeration system. Do not use it for special purposes such as maintaining pets, food, precision machinery, or art objects.
- When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
- Make sure the air inlet and outlet are free from obstructions.
- Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
- Do not step on or place heavy objects on top of the appliance.
- Do not operate the appliance without the filter securely installed.
- Do not drink water drained from the appliance.
- Be sure to ventilate sufficiently when the air conditioner and a heating appliance such as a heater are used simultaneously.
- Do not expose people, animals, or plants to the cold or hot wind from the air conditioner for extended periods of time.
- Remove the batteries if the remote control is not to be used for an extended period of time.
- Never mix different types of batteries, or old and new batteries for the remote control.
- Stop using the remote control if there is a fluid leak in the battery. If your clothes or skin are exposed to the leaking battery fluid, wash off with clean water.
- If the leaking battery fluid has been swallowed, rinse the inside of the mouth thoroughly and consult a doctor.
- Do not recharge or disassemble the batteries.
MAINTENANCE
- Clean the filter every two weeks.
- Never touch the metal parts of the air conditioner when removing the air filter.
- Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water. Use a smooth cloth.
REFRIGERANT (FOR R32 ONLY)
WARNING
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames an operating gas appliance or an operating electric heater).
- Do not pierce or burn. Be aware that flammable refrigerants may not contain an odor.
CAUTION
- This unit contains flammable refrigerant and has special safety precautions not normally associated with older units. Please follow all precautions and advisories.
- Use caution while handling and prevent damage to unit. Do not put any holes into product for any reason. This can cause damage to product and prevent unit from cooling.
- Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly clean unit can result in damage to the refrigeration system and or the electrical system.
- Make certain that all the air circulation/ventilation openings are free from obstruction.
- Service should only be performed by technicians properly trained and certified in the use of flammble refrigerants. Any service performed by unauthorized servicers/individuals will void all warranties.
- When storing the appliance, do not put in a room with any open flame appliance, such as gas water heaters or furnaces. Also keep away from electric heaters. Damaged units should be repaired before storage.
PRODUCT OVERVIEW
Exterior Parts
- Control Panel
- Remote Control
- Air Filter
- Vertical Air Deflector (Horizontal Louver)
- Horizontal Air Deflector (Vertical Louver)
- Air Inlet
- Front Grille
- Cabinet
- Air Outlet
Interior Parts
- Evaporator
- Air Guide
- Control Box
- Condenser
- Compressor
- Base Pan
- Power Cord
INSTALLATION
Electrical Data
Power cord may include a current interrupter device. TEST and RESET buttons
are provided on the plug case. The device should be tested on a periodic basis
by frist pressing the TEST button and then the RESET button. If the TEST
button does not trip or if the RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified service technician.
for 120 V
WARNING
- This appliance should be installed in accordance with the National Electrical Code.
- Use of extension cords could cause serious injury or death.
- Do not use an extension cord with this window air conditioner.
- Do not use surge protectors or multi-outlet adapters with this window air conditioner.
- Never push the TEST button during operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this plug. If this device trips, the cause should be corrected before further use.
CAUTION
- The conductors inside this cord are surrounded by shields, which monitor leakage current. These shields are not grounded. Periodically examine the cord for any damage. Do not use this product in the event the shields become exposed. Avoid shock hazard. This unit cannot be user-serviced. Do not open the tamperresistant sealed portion. All warranties and performance will be voided. This unit is not intended to be used as an ON/OFF switch.
Parts Included (Appearance May Vary)
Tools Needed
How to Install the Unit
- To prevent vibration and noise, make sure the unit is installed securely and firmly.
- Install the unit out of direct sunlight.
- There should be no obstacles, such as a fence or wall, within 20” from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
- Install the unit slightly tilted so the back is slightly lower than the front (about 1/4”). This will force condensed water to flow to the outside.
- Install the unit with the bottom between 30”~ 60” above the floor level.
Window Requirements
- This unit is designed for installation in standard double hung windows with actual opening widths from 22” to 36”.The top and bottom window sashes must open sufficiently to allow a clear vertical opening of 13” from the bottom of the upper sash to the inside sill.
NOTE
- All supporting parts should be secured to firm wood, masonry, vinyl, fiberglass, or metal.
- This product is a window air conditioner. As such, a standard single-hung or double-hung window is required for proper installation. Non-window installations, including using sleeves or wall openings, and other installation methods are not recommended.
Storm Window Requirements
- Windows that include a storm window frame may prevent the air conditioner from tilting down toward the outside to drain properly. For proper drainage, attach a 1” x 2” piece of wood to the inner sill, trimmed to a length which fits inside the window frame. The top of the wood shim must be at least 3/4” higher than the top of the storm window frame. Attach the wood securely to the sill with nails or screws.
- If necessary, attach another 1” x 2” wood strip flush against the back of the inner sill. This will raise the L bracket, as shown in the drawing.
Preparation of the Chassis
- Insert the top and bottom rails of the curtain Preparation of the Chassis 1 Insert the top and bottom rails of the curtain
- Cut the window sash seals to the proper length. Peel off the backing and attach the adhesive-backed foam to the underside of the window sash and bottom of the window frame.
- Open the window and draw a center line on the center of the inner sill. Then mark lines 8” to the left and right of the center line.
- Install the L bracket behind the inner window sill as shown. Use the 2 type A screws provided.
NOTE
- The bracket helps to hold unit securely in place. Be sure to place bracket edge flush against back of inner sill.
Unit Installation
CAUTION
- During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from window.
- Set the air conditioner in the window so that is centered. Place the air conditioner so that front edge of the bottom guide is against the back edge of the sill. Bring the window down so that the front edge of the upper guide is in front of the window. Make sure that air conditioner is level or tilting slightly to the outside.
- Extend the guide panels to fill the window opening and use 4 type B screws to secure them to the window.
- Cut the non-adhesive foam strip to the proper length and insert it between the upper window sash and the lower window sash.
- To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the L bracket with a type A screw.
- Remove the screw from the bottom right of the cabinet. Attach the support bracket using the screw you just removed. Secure the support bracket to the inner window sill using a type B screw.
- After the air conditioner is installed, measure the curtain panel on each side and cut the adhesive-backed heatproof foam to fit each panel. The size of the panels may differ. Remove the backing from the heatproof foam and attach the foam to the curtain panels.
NOTE
- Heatproof foam improves the cooling capability of the air conditioner.
- See the Electrical Data section for information on attaching the power cord to an electrical outlet.
OPERATION
Control Panel and Remote Control
NOTE
- The feature may be changed according to the type of model.
1 Power
Press to turn the air conditioner ON or OFF.
2 Sleep Mode
This mode keeps operating noise to a minimum and turns the air conditioner off after a set time. The timer can be set from 1 to 12 hours.
- In the Sleep Mode, the setting temperature increases by 2 °F after 30 minutes and additional 2 °F after another 30 minutes for a more comfortable sleep.
- The setting temperature increases up to 4 °F from the preset temperature.
Delay ON/OFF Timer
Delay ON – When the air conditioner is off, set it to automatically turn
on from 1 to 24 hours later, at its previous mode and fan settings.
Delay OFF – When the air conditioner is on, set it to automatically turn
off from 1 to 24 hours later.
NOTE
- Each press of the Timer button advances the timer by 1 hour. After the last press the display returns to the temperature setting.
4 Operation Mode
Press the Mode button to cycle between 4 types of air conditioner operation:
Energy Saver / Cool / Fan / Dry.
Energy Saver – In this mode the compressor and fan turn off when the set
temperature is achieved. Approximately every 3 minutes the fan turns on to
allow the unit sensor to accurately determine if more cooling is needed.
Cool – This mode is ideal on hot days to cool and dehumidify the room
quickly. Use the Temp buttons to set the desired room temperature and use the
Fan Speed button to set the desired fan circulation speed.
Fan – In this mode the fan circulates air but the compressor does not
run. Use the Fan Speed button to set fan speed to High, Medium or Low. In this
mode, you cannot adjust the set temperature.
Dry – This mode is ideal for rainy and damp days to dehumidify the room
rather than cooling it significantly. Humidity is removed from the room by the
combination of compressor operation and the fan speed fixed at Low. The
compressor and fan turn off once the set temperature is reached. Fan speed
cannot be adjusted in Dry mode.
5 Wi-Fi
Enables connection of the air conditioner to the home Wi-Fi.
NOTE
- Follow instructions on ThinQ application on how to connect to your unit.
6 Clean Filter
- The filter reset must be done using the control panel, not the remote control.
- This feature is a reminder to clean the air filter for more efficient operation. The LED light turns on after 250 hours of operation.
7 Fan Speed
Press to set the Fan Speed to Low (F1), Medium (F2) or High (F3).
8 Temperature Control
The thermostat monitors room temperature to maintain the desired temperature. The thermostat can be set between 60 °F–86 °F (16 °C–30 °C). Press or arrows to increase or decrease temperature setting.
9 Energy Saver
In this mode the compressor and fan turn off when the set temperature is
achieved. Approximately every 3 minutes the fan turns on to allow the unit
sensor to accurately determine if more cooling is needed.
NOTE
- This function is available with Cooling Mode.
10 Clear
Cancel Sleep and Timer settings.
NOTE
- Auto Restart : If the air conditioner turns off due to a power outage, it will restart automatically once the power is restored, with the same settings as were set before the unit turned off.
- Energy Saver : The unit defaults to the Energy Saver mode each time the unit is switched on except in Fan mode or when power is restored after an electrical power outage.
- The remote control will not function properly if the AC infrared sensor is exposed to direct light or if there are obstacles between the remote controller and the air conditioner.
Using the Light Off Function
You can set the brightness of the control panel,
- Press Mode button on the remote control for 3 seconds, or
- Press Mode and Sleep button button together on the control panel.
NOTE
- Turn on/off the control panel.
Using the Auto Clean Function
In the Cooling and Dry Mode, Moisture is generated inside the indoor unit.
This function removes such moisture.
- Press Energy Saver button on the remote control for 3 seconds.
- is displayed on the remote control.
NOTE
- If you turn off the unit, the fan continues to run for 10 minutes and cleans the inside of the indoor unit.
Wireless Remote Control
Inserting Batteries
If the display screen of the remote control begins to fade, replace the
batteries. Insert AAA (1.5 V) batteries before using the remote control.
- Remove the cover on the back of the remote
- With the plus and minus poles facing as
NOTE
- Two new batteries are supplied with the air conditioner for use in the remote control.
- Do not use a rechargeable battery. Make sure that the battery is new.
- In order to prevent discharge, remove the battery from the remote control if the air conditioner is not going to be used for an extended period of time.
- Keep the remote control away from extremely hot or humid places.
- To maintain optimal operation of the remote control, the remote sensor should not be exposed to direct sunlight.
Air Direction
Airflow can be adjusted by changing the direction of the air conditioner’s
louvers.
Adjusting Horizontal Airflow Direction
The horizontal airflow is adjusted by moving the levers of the vertical
louvers to the left or right.
Adjusting Vertical Airflow Direction
Touch the horizontal louvers to adjust the airflow up or down.
NOTE
- When the weather is extremely hot, the unit may turn off automatically to protect the compressor.
Additional Features
Slinger Fan
This air conditioner is equipped with a slinger fan. (See drawing.) The fan’s
outer ring picks up the condensed water from the base pan if the water level
gets high enough. The water is then picked up by the fan and expelled through
the condenser, making the air conditioner more efficient.
FCC Notice
The following notice cover the transmitter module contained in this product. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference and
- This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC RF Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be colocated or operating
in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with a minimum distance of 20
cm (7.8 inches) etween the antenna and your body. Users must follow the
specific operating instructions for satisfying RF exposure compliance.
Wireless LAN Module Specifications
MAINTENANCE
WARNING
- Before cleaning or performing maintenance, disconnect the power supply and wait until the fan stops.
Air Filter
Check the air filter at least twice a month to see if cleaning is necessary.
Trapped particles in the filter can build up and block the airflow, reducing
cooling capacity and causing an accumulation of frost on the evaporator.
Cleaning the Air Filter
- Remove the air filter from the front grille by pulling the filter forward and then up slightly.
- Wash the filter using lukewarm water below 40 °C (104 °F).
- Gently shake the excess water from the filter and replace it.
Cleaning the Air Conditioner
- Wipe the front grille and inlet grille with a cloth dampened in a mild detergent solution.
- Wash the cabinet with mild soap or detergent and lukewarm water, then polish using liquid appliance wax.
NOTE
- To ensure continued peak efficiency, the condenser coils (outside of unit) should be checked periodically and cleaned if clogged with soot or dirt from outside air.
- For repair and maintenance, contact an Authorized Service Center. See the warranty page for details or call 1-800-243-0000. Have your model number and serial number available. They can be found on the side of the cabinet. Record them on page 27 for future reference.
TROUBLESHOOTING
Before Calling for Service
The appliance is equipped with an automatic error-monitoring system to detect
and diagnose problems at an early stage. If the appliance does not function
properly or does not function at all, check the following before you call for
service.
Normal Sounds You May Hear
-
High Pitched Chatter
Today’s high efficiency compressors may have a high pitched chatter during the cooling cycle. -
Sound of Rushing Air
At the front of the unit, you may hear the sound of rushing air being moved by the fan. -
Gurgle/Hiss
Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation. -
Vibration
Unit may vibrate and make noise because of poor wall or window construction or incorrect installation. -
Pinging or Swishing
Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds.
Problem | Possible Causes & Corrective Action |
---|
Air conditioner does not start.
| The air conditioner is unplugged.
· Make sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.
· Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
Power failure.
· If power failure occurs, turn the mode control to off. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
The current interrupter device is tripped.
· Press the RESET button located on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Air conditioner does not cool as it should.
| Airflow is restricted.
· Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
The temp control may not be set correctly.
· Set the desired temperature to a level lower than the current temperature.
The air filter is dirty.
· Clean the filter at least every 2 weeks. See the ‘MAINTENANCE’ section.
The room may have been hot.
· When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping.
· Check for open fumace floor registers and cold air returns.
Cooling coils have iced up.
· See ‘Air conditioner freezing up’ below.
Air conditioner freezing up.| The cooling coils are iced over.
· Ice may block the air flow and obstruct the air conditioner from properly cooling the room. Set the mode control at High Fan or High Cool.
Water drips outside.| Hot, humid weather.
· This is normal.
Problem | Possible Causes & Corrective Action |
---|
Water drips Indoors.
| The air conditioner is not tilted to the outside.
· For proper water disposal, make sure the air conditioner slants slightly from the cabinet front to the rear.
Water collects in base pan.| Moisture removed from air and drains into base pan.
· This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas.
Air conditioner turns on and off rapidly.
| Dirty air filter – air restricted.
· Clean air filter.
Outside temperature extremely hot.
· Refer to installation instructions or check with installer.
Noise when unit is cooling.
| Air movement sound.
· This is normal. If too loud, set to lower FAN Setting.
Window vibration – poor installation.
· Refer to installation instructions or check with installer.
Room too cold.| Set temperature too low.
· Increase set temperature.
Remote sensing deactivating prematurely.
| Remote control not located within range.
· Place remote control within 20 feet & 120° radius of the front of the unit.
Remote control signal obstructed.
· Remove obstruction.
Can’t connect the LG ThinQ App. to the air conditioner.
| Air conditioner is turned off.
· Turn the air conditioner on.
Wireless router is turned off.
· Turn the router on.
The air conditioner is not connecting to the Wi-Fi.
| The Wi-Fi router is too far from the air conditioner.
· Move the router closer to the air conditioner or purchase and install a Wi- Fi repeater (signal booster).
You do not have permission to use the router or it is incompatible.
· Make sure you are selecting the correct wireless router from the list. The router must be set to 2.4 GHz.
Problem | Possible Causes & Corrective Action |
---|
Trouble connecting appliance and smartphone to Wi-Fi network.
| The password for the Wi-Fi network was entered incorrectly.
· Delete your home Wi-Fi network and begin the registration process again.
Mobile data for your smartphone is turned on.
· Turn off the Mobile data of your smartphone before registering the appliance.
The wireless network name (SSID) is set incorrectly.
· The wireless network name (SSID) should be a combination of English letters and numbers. (Do not use special characters.)
The router frequency is not 2.4 GHz.
· Only a 2.4 GHz router frequency is supported. Set the wireless router to
2.4 GHz and connect the appliance to the wireless router. To check the router frequency, check with your Internet service provider or the router manufacturer.
The appliance is too far from the router.
· If the appliance is too far from the router, the signal may be weak and the connection may not be configured correctly. Move the router closer to the appliance or purchase and install a Wi-Fi repeater.
NOTE
- You can refer to the Energy Star program in detail at www.energystar.gov.
- If you see “CH” in the display, please call 1-800-243-0000.
WARRANTY
ARBITRATION NOTICE: THIS LIMITED WARRANTY CONTAINS AN ARBITRATION PROVISION
THAT REQUIRES YOU AND LG TO RESOLVE DISPUTES BY BINDING ARBITRATION INSTEAD OF
IN COURT, UNLESS YOU CHOOSE TO OPT OUT. IN ARBITRATION, CLASS ACTIONS AND JURY
TRIALS ARE NOT PERMITTED. PLEASE SEE THE SECTION TITLED “PROCEDURE FOR
RESOLVING DISPUTES” BELOW.
WHAT THIS WARRANTY COVERS:
LG Electronics U.S.A., Inc. (“LG”) warrants your LG Room Air Conditioner
(“product”) against defect in materials or workmanship under normal household
use, during the warranty period set forth below, LG will, at its option,
repair or replace the product. This limited warranty is valid only to the
original retail purchaser of the product, is not assignable or transferrable
to any subsequent purchaser or user, and applies only when the product is
purchased through an LG authorized dealer or distributor and used within the
United States (“U.S.”) including U.S. Territories.
NOTE
- Replacement products and repair parts may be new or factory-remanufactured and are warranted for the remaining portion of the original unit’s warranty period or ninety (90) days, whichever is longer. Please retain dated receipt or delivery ticket as evidence of the Date of Purchase for proof of warranty (you may be required to submit a copy to LG or authorized representative).
WARRANTY PERIOD:
1 year from the Date of Purchase: Any internal/ functional Parts and Labor
HOW SERVICE IS HANDLED: In-Home Service
In-home service will be provided during the warranty period subject to
availability within the United States. In-home service may not be available in
all areas. To receive in-home service, the product must be unobstructed and
accessible to service personnel. If during in-home service repair cannot be
completed, it may be necessary to remove, repair and return the product. If
in-home service is unavailable, LG may elect, at our option, to provide for
transportation of our choice to and from a LG authorized service center.
THIS LIMITED WARRANTY DOES NOT COVER:
- Service trips to deliver, pick up, or install the product or for instruction on product use.
- Replacing house fuses or resetting of circuit breakers, correction of house wiring or plumbing, or correction of product installation.
- Damage or failure caused by leaky / broken / frozen water pipes, restricted drain lines, inadequate or interrupted water supply or inadequate supply of air.
- Damage or failure caused by accidents, pets and vermin, lightning, wind, floods or acts of God.
- Damage or failure resulting from misuse, abuse, improper installation, repair or maintenance. Improper repair includes use of parts not approved or specified by LG.
- Damage or failure caused by unauthorized modification or alteration to the product.
- Damage or failure caused by incorrect electrical current, voltage, or plumbing codes.
- Cosmetic damage, including scratches, dents, chips or other damage to finish of the product, unless such damage results from defects in materials or workmanship and is reported to LG within seven (7) calendar days from the date of delivery.
- Damage or missing items to any display, open box, discounted, or refurbished product.
- Product where the original factory serial numbers have been removed, defaced or changed in any way.
- Repairs when product is used in other than normal and usual household use (e.g. rental, commercial use, offices, or recreational facilities) or contrary to the instructions outlined in the owner’s manual.
- The removal and reinstallation of the Product if it is installed in an inaccessible location.
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING
AND WITHOUT LIMITATION TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW,
THIS WARRANTY IS LIMITED IN DURATION TO THE TERM PERIOD EXPRESSED ABOVE.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY
FOR THE CUSTOMER. NEITHER THE MANUFACTURER NOR ITS U.S. DISTRIBUTOR SHALL BE
LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE
DAMAGES OF ANY NATURE, INCLUDING AND WITHOUT LIMITATION TO, LOST REVENUES OR
PROFITS, OR ANY OTHER DAMAGE, WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE.
Some states do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty lasts, so
the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights and you may also have other rights that vary from
state to state.
HOW TO OBTAIN WARRANTY SERVICE & ADDITIONAL INFORMATION:
Call 1-800-243-0000 or visit our
website at www.lg.com.
Mail to: LG Customer Information Center (ATTN: CIC)
FOR YOUR RECORDS
Write the model and serial numbers here:
Model No. Serial No.
- This information is located on a label on the side of the unit.
- Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
PROCEDURE FOR RESOLVING DISPUTES:
ALL DISPUTES BETWEEN YOU AND LG ARISING OUT OF OR RELATING IN ANY WAY TO THIS
LIMITED WARRANTY OR THE PRODUCT SHALL BE RESOLVED EXCLUSIVELY THROUGH BINDING
ARBITRATION, AND NOT IN A COURT OF GENERAL JURISDICTION. BINDING ARBITRATION
MEANS THAT YOU AND LG ARE EACH WAIVING THE RIGHT TO A JURY TRIAL AND TO BRING
OR PARTICIPATE IN A CLASS ACTION.
Definitions. For the purposes of this section, references to “LG” mean LG
Electronics U.S.A., Inc., its parents, subsidiaries and affiliates, and each
of their officers, directors, employees, agents, beneficiaries, predecessors
in interest, successors, assigns and suppliers; references to “dispute” or
“claim” shall include any dispute, claim or controversy of any kind whatsoever
(whether based in contract, tort, statute, regulation, ordinance, fraud,
misrepresentation or any other legal or equitable theory) arising out of or
relating in any way to the sale, condition or performance of the product or
this Limited Warranty.
Notice of Dispute. In the event you intend to commence an arbitration
proceeding, you must first notify LG in writing at least 30 days in advance of
initiating the arbitration by sending a letter to LG at LG Electronics, USA,
Inc. Attn: Legal Department- Arbitration 111 Sylvan Avenue, Englewood Cliffs,
NJ 07632. You and LG agree to engage in good faith discussions in an attempt
to amicably resolve your claim. The notice must provide your name, address,
and telephone number; identify the product that is the subject of the claim;
and describe the nature of the claim and the relief being sought. If you and
LG are unable to resolve the dispute within 30 days, either party may proceed
to file a claim for arbitration.
Agreement to Binding Arbitration and Class Action Waiver. Upon failure to
resolve the dispute during the 30 day period after sending written notice to
LG, you and LG agree to resolve any claims between us only by binding
arbitration on an individual basis, unless you opt out as provided below. Any
dispute between you and LG shall not be combined or consolidated with a
dispute involving any other person’s or entity’s product or claim. More
specifically, without limitation of the foregoing, any dispute between you and
LG shall not under any circumstances proceed as part of a class or
representative action. Instead of arbitration, either party may bring an
individual action in small claims court, but that small claims court action
may not be brought on a class or representative basis.
Arbitration Rules and Procedures. To begin arbitration of a claim, either you
or LG must make a written demand for arbitration. The arbitration will be
administered by the American Arbitration Association (“AAA”) and will be
conducted before a single arbitrator under the AAA’s Consumer Arbitration
Rules that are in effect at the time the arbitration is initiated (referred to
as the “AAA Rules”) and under the procedures set forth in this section. The
AAA Rules are available online at www.adr.org/consumer. Send a copy of your
written demand for arbitration, as well as a copy of this provision, to the
AAA in the manner described in the AAA Rules. You must also send a copy of
your written demand to LG at LG Electronics, USA, Inc. Attn: Legal Department-
Arbitration 111 Sylvan Avenue, Englewood Cliffs, NJ 07632. If there is a
conflict between the AAA Rules and the rules set forth in this section, the
rules set forth in this section will govern. This arbitration provision is
governed by the Federal Arbitration Act. Judgment may be entered on the
arbitrator’s award in any court of competent jurisdiction. All issues are for
the arbitrator to decide, except that issues relating to the scope and
enforceability of the arbitration provision and to the arbitrability of the
dispute are for the court to decide. The arbitrator is bound by the terms of
this provision.
Governing Law. The law of the state of your residence shall govern this
Limited Warranty and any disputes between us except to the extent that such
law is preempted by or inconsistent with applicable federal law.
Fees/Costs. You do not need to pay any fee to begin an arbitration. Upon
receipt of your written demand for arbitration, LG will promptly pay all
arbitration filing fees to the AAA unless you seek more than
$25,000 in damages, in which case the payment of these fees will be governed
by the AAA Rules. Except as otherwise provided for herein, LG will pay all AAA
filing, administration and arbitrator fees for any arbitration initiated in
accordance with the AAA Rules and this arbitration provision. If you prevail
in the arbitration, LG will pay your attorneys’ fees and expenses as long as
they are reasonable, by considering factors including, but not limited to, the
purchase amount and claim amount. Notwithstanding the foregoing, if applicable
law allows for an award of reasonable attorneys’ fees and expenses, an
arbitrator can award them to the same extent that a court would. If the
arbitrator finds either the substance of your claim or the relief sought in
the demand is frivolous or brought for an improper purpose (as measured by the
standards set forth in Federal Rule of Civil Procedure 11(b)), then the
payment of all arbitration fees will be governed by the AAA Rules. In such a
situation, you agree to reimburse LG for all monies previously disbursed by it
that are otherwise your obligation to pay under the AAA Rules. Except as
otherwise provided for, LG waives any rights it may have to seek attorneys’
fees and expenses from you if LG prevails in the arbitration.
Hearings and Location. If your claim is for $25,000 or less, you may
choose to have the arbitration conducted solely on the basis of (1) documents
submitted to the arbitrator, (2) through a telephonic hearing, or (3) by an
in-person hearing as established by the AAA Rules. If your claim exceeds
$25,000, the right to a hearing will be determined by the AAA Rules. Any in-
person arbitration hearings will be held at a location within the federal
judicial district in which you reside unless we both agree to another location
or we agree to a telephonic arbitration.
Opt-Out. You may opt-out of this dispute resolution procedure. If you
opt-out, neither you nor LG can require the other to participate in an
arbitration proceeding. To opt-out, you must send notice to LG no later than
30 calendar days from the date of the first consumer purchaser’s purchase of
the product by either: (i) sending an e-mail to optout@lge.com, with the
subject line: “Arbitration Opt-Out” or (ii) calling
1-800-980-2973. You must include in the
opt-out e-mail or provide by telephone: (a) your name and address; (b) the
date on which the product was purchased; (c) the product model name or model
number; and (d) the serial number (the serial number can be found (i) on the
product; or (ii) online by accessing https://www.lg.com/us/support/repair-
service/schedule-repair-continued and clicking on “Find My Model & Serial
Number”).
You may only opt out of the dispute resolution procedure in the manner
described above (that is, by e-mail or telephone); no other form of notice
will be effective to opt-out of this dispute resolution procedure. Opting out
of this dispute resolution procedure will not affect the coverage of the
Limited Warranty in any way, and you will continue to enjoy the full benefits
of the Limited Warranty. If you keep this product and do not opt-out, then you
accept all terms and conditions of the arbitration provision described above.
References
- LG Open Source
- Homepage | ENERGY STAR
- LG Electronics & Home Appliances | Shop Now | LG USA
- LG Open Source
- Request Product Repair Service | LG USA Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>