BASEMENT WATCHDOG SIT-33D SIT Series Sump Pumps Instructions

June 5, 2024
BASEMENT WATCHDOG

BASEMENT WATCHDOG SIT-33D SIT Series Sump Pumps

BASEMENT WATCHDOG SIT-33D SIT Series Sump Pumps

Basement Watchdog SIT Series Sump Pumps (SIT-33D/SIT-50D)

  • Remove all debris from the bottom of the pit.
  • Remove all debris floating in the water.
  • Remove all debris from the float switch cage.
  • Remove all debris around the air relief valve.
  •  Fill the pit with water. Make sure pump turns on at the intended level.
  • While the pump is running, make sure pump is evacuating water at a good pace.
  • While the pump is running, make sure a stream of water is escaping from the air relief valve.
  • If not, clear the hole of any deposits or debris.
  • If your pit, pump and discharge lines have developed a reddish, slimy buildup (iron ochre) or other deposits, use Basement Wash-Dog™, a pit cleaner that will address the buildup and leave your sump system flowing freely.

PARTS & SERVICE INFORMATION

You can receive technical support, parts, or service by calling Glentronics, Inc. at 800-991-0466, Option #3, emailing us at Service@Glentronics.com  or by visiting the Basement Watchdog website at www.basementwatchdog.com Send your unit to the address (right) if repairs are needed:

CONTACT US

  • Glentronics, Inc.
  • ATTN: Repairs
  • 645 Heathrow Drive
  • Lincolnshire, IL 60069-4205