Gallet PEP 906 Valence Electronic Glass Personal Scale Instruction Manual
- June 5, 2024
- Gallet
Table of Contents
INSTRUCTION MANUAL
PEP 906
**Valence
Pese-personne electronique en verre
**
Dear customer, thank you for purchasing our product. Please read the operating instructions carefully before putting the appliance into operation and keep these instructions including the warranty, the receipt, and, if possible, the box with the internal packing.
General Safety Instructions
- The appliance is designed exclusively for private use and for envisaged purposes.
- This appliance is not fit for commercial use.
- Keep it away from sources of heat, direct sunlight, humidity (never dip it into any liquid), and sharp edges. Do not use the appliance with wet hands.
- If you should leave the workplace, always switch the machine off.
- Do not try to repair the appliance on your own. Always contact an authorized technician.
- Pay careful attention to the following “Special Safety Instructions for this unit“.
Special safety instructions for this unit
- Operate the appliance only in accordance with the specifications on the rating plate.
- Do not put the appliance in wet places.
- Clean the scale with a slightly damp cloth. Do not immerse the scale in the water or use chemical/abrasive agents.
- Always use the scale on a hard, flat surface. DO NOT use on carpet
- DO NOT use the scale on wet and slippery floors. DO NOT step on the edge of the scale. The scale platform is slippery when wet. Keep it dry!.
- Always weigh yourself with the same scales placed on the same surface. Uneven floors may affect the reading.
- Weigh yourself without clothing and footwear, before meals and always at the same time of day.
- To make sure accuracy of testing, please DO NOT use the scale in an environment with a strong electromagnetic field.
- DO NOT use the scale on wet and slippery floors. DO NOT step on the edge of the scale. The scale platform is slippery when wet. Keep it dry!
- DO NOT use this scale on a place with an intense shake. Keep stand still on the scale when testing.
- Do not drop the device, or jump on the device when using it. Avoid strong impact and sudden shake as it is a precision measuring device. The construction is delicate and sensitive to all unwanted external impacts.
- This appliance is not intended for use by person people (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instructions concerning the way of using the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
Description of the controls
P1. Unit of scale
P2. Display
P3. Glass surface
Instructions for Use
1 pc of lithium battery (CR2032).
Please remove the isolation sheet from the battery contact before use. Please
take note to the polarity.
To replace battery
Open the battery case cover on the back of the scale, if the battery case is
the type shown in the picture. Bend the small black tab outwards and the
battery will come out. Take note not to bend the contact.
Install a new battery by putting one side of the battery beneath the contact
and then pressing down the other side.
Operation
- Put the scale on a hard and flat surface (avoid carpet or soft surface).
Gently step on the scale, then the scale will be automatically turned on. Stand evenly on the scale without moving and wait until your weight shown on display is stable and locked.
Step off the scale when „0.0“ appear you can measure again.
Automatic switch-off
When you step off the scale, it will automatically switch off. Auto shut-off
occurs if the display shows „0.0“ or shows the same weight reading for
approximately 8 seconds..
Note:
If the scale was moved to new place, it may cause some errors for the first
time.
Troubleshooting
Error and another LCD message
LCD may show occasionally an error message. Simply turn off the unit for a
brief moment, or remove and re-install the battery as a total re-set. Then
turn on again to resume operation.
If, when you tap the scale to activate it, there is no display at all or „LO“
is displayed- try two new batteries.
Scale overload.
Please step off to avoid damage.
Re-test
Display „C“ when you step off the scale, which means this weight reading with
an error. Please re-test.
Troubleshooting guide
- Check the rights position of the battery and the polarity.
- When a warning indicator shows „Lo“ replace the battery.
- Check whether the scale is on a flat, level floor and not touching a wall.
Cleaning and Maintenance
- Use a dry, soft fabric to clean the device. Or a lightly damp soft fabric with mild detergent to wipe clean the device. Do not use strong chemical solutions such as alcohol, or benzene for cleaning.
- It could be slippery when the unit platform surface is wet, or semi-damp. Ensure the weighing platform surface is dry before using for safety reasons.
Technical specifications
- Electronic personal glass scale
- Capacity 150 kg
- Graduation 100 g
- System of turning ON the scale AUTO STEP ON – just step on the scale and stand still, the scale will automatically turn ON and start taking measurements.
- 6 mm tempered glass surface
- Auto off, auto zero
- Overload indicator
- Low battery indicator
- Batteries operated 1 x CR 2032 3V (included)
- Size: 30,2 x 3,3 x 30,2 cm
- Weight: 1,6 kg
We reserve the right to change technical specifications.
WARNING: Do not use this product near water, in wet areas to avoid fire
or injury of electric current. Always turn off the product when you don’t use
it or before a revision. There aren’t any parts in this appliance that are
reparable by consumers. Always appeal to a qualified authorized service. The
product is under dangerous tension.
Old electrical appliances used batteries and accumulators disposal
This symbol appears on the product, on the product accessories or on the
product packing means that the product must not be disposed of as household
waste. When the product/ battery durability is over, please, deliver the
product or battery (if it is enclosed) to the respective collection point,
where the electrical appliances or batteries will be recycled. The places,
where the used electrical appliances are collected, exist in the European
Union and in other European countries as well. By proper disposal of the
product, you can prevent possible negative impacts on the environment and
human health, which might otherwise occur as a consequence of improper
manipulation with the product or battery/ accumulator. Recycling of materials
contributes to the protection of natural resources. Therefore, please, do not
throw the old electrical appliances and batteries/ accumulators in the
household waste. Information, about where it is possible to leave the old
electrical appliances for free, is provided at your local authority, at the
store where you have bought the product. Information, on where you can leave
the batteries and accumulators for free, is provided to you at the store, at
your local authority.
References
- Úvod - ECOBAT
- Úvod | ELEKTROWIN, a.s.
- Úvod - Envidom
- HP Tronic.cz | hptronic.cz
- SEWA - OZV | elektroodpad | batérie | obaly
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>