(V5H(2G-60))
LED instruction.
NO| Test item| Instruction|
Result
---|---|---|---
1| LED in Idle Mode| Press the start button for 1 second when the power of the
logger is normal| LED toggle red/blue twice
2| Press the start button for 1 second when the power of the logger is low|
No LED light under any condition
3| Press and hold the Flight button for 5 seconds| No LED light and logger can
not enter Flight Mode
4| Press and hold the start button for 5 seconds then logger from Idle mode to
Recording mode| The status LED flashes Blue every 10 seconds for 30 minutes to
indicate it has started properly After 30 minutes this flash sequence will
stop
NO| Test item| Instruction|
Result
---|---|---|---
5| LED in Recording
Mode| Press the start button for 1 second when the power of the logger is
normal| Blue flash indicates logger is recording
6| Press the start button for 1 second when the power of the logger is low| No
flash means low battery (no LED) Battery is dead
7| press the Flight button for 1 second| No Flash means the logger is not
enabled Flight Mode
NO| Test item| Instruction|
Result
---|---|---|---
8| LED in Flight Mode| Press and hold the Flight button for 5 seconds then
logger from Recording Mode to Flight Mode| Flight Mode LED blink Red LED 5
times to indicate logger has entered Flight Mode
9| Singlepress Flight button for 1 second and a Red LED light indicates| Red
LED light indicates itis flight mode
10| Press and hold the flight mode button for 5 seconds| Red LED to go solid
for 5 seconds and exit Flight Mode
Key function instruction
NO| Test item| Instruction|
Result
---|---|---|---
1| Start| Press and hold the start button for 5 seconds to enable the logger
to record data| Logger data upload to platform, read interval is 10mins and
report interval is 60mins
---|---|---|---
NO| Test item| Instruction|
Result
---|---|---|---
2| Flight Mode| In Recording Mode, Press and hold the Flight button for 5
seconds enable the logger to Flight Mode| Logger continues to record data but
will stop uploading data to the platform until it exits Flight Mode
3| press and hold the Flight button for 5 seconds exit Flight Mode after
logger in Flight Mode for 12 hours| platform and device data are not lost
NO| Test item| Instruction|
Result
---|---|---|---
4| Stop| In recording mode, connect usb cable to the logger| logger stop
then the user can view PDF or export PDF to PC
5| In-Flight Mode, Connect usb cable to the logger| logger will stop then the
user can view PDF or export PDF to PC
User experience instruction.
NO| Test item| Instruction|
Result
---|---|---|---
1| Capacity display| Check whether the Capacity display matches with real
battery capacity.| The Capacity display match with real battery capacity.
2| Reporting stable| Check the Reporting performance in a different
environment. ff| Reporting normally in different environments.
3| PDF function| Stop logger then export PDF| PDF content is displayed
correctly and data is not lost
4| Power consumption| Enble logger then set the report interval to 20min| Meet
company quality standard
Usage scenarios
Put the device in the container with goods together.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device and its antenna(s) must not be co-located or operated in
conjunction with any other antenna or transmitter.
To maintain compliance with FCC’s RF exposure guidelines, This equipment
should be installed and operated with a minimum distance of 20cm from your
body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>