WILTEC 51554 Swimming Pool Pump User Manual
- June 5, 2024
- wiltec
Table of Contents
WILTEC 51554 Swimming Pool Pump
Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly. Updating the documentation If you have suggestions for improvement or have found any irregularities, please contact us.
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Keep these operation instructions safe.
Features
- Pump casing, lid and impeller made of high-quality plastic
- Big outlet, high discharge head and quiet operation
- Good mechanical gasket with long lifespan
- Includes overload protection to allow continuous operation
- With simple suction and pressure line connections
Notes on application
- The swimming pool pumps are designed for small pools (family use), whirlpools and sauna swimming pools. We recommend the use of a pre-filter.
- Caution! Near swimming pools and garden ponds and in their protection area, the use of the pump is only allowed with a fault-current circuit breaker (30 mA) according to DIN VDE 100 part 702 06.92. If you have any questions, please ask a qualified technician.
- Keep an adequate safety distance to the swimming pool and mount the pump to a stable ground panel. According to the VDE a safety distance of 2 m should be kept.
- We do not bear liability for the consequences of improper installation, commissioning, and elec-trical installations, which are not according to regulations.
- The electricity cable needs to comply with the EG norm (2) or type H07 RN-F according to VDE 0620.
- The device is not meant to be operated by people (including children) with limited physical, sensory, or mental abilities or lack of knowledge and/ or experience, unless they are supervised by a person responsible for their safety or are being instructed on how to operate the device.
- Children should be supervised, when around the device to ensure they do not play with it.
Safety instructions
- Visually examine the device before every use. Do not use the device if safety precautions are damaged or worn-out. Never override safety measurements.
- Only use the device for the purpose described in this operating manual.
- Do not connect the device to the electricity supply before all parts have been installed.
- You are responsible for the safety in the working/ operating area.
- If the cable or socket should be damaged due to external influences, it must not be repaired!The electricity cable needs to be exchanged for a new one by a qualified technician only.
- The voltage of 230 V AC (as stated on the type label) needs to match the mains voltage availa-ble.
- Never lift, transport, or attach the device by its cable.
- Make sure that all electrical connections are in an area, which is flood-proof and protected from moisture.
- Before carrying any work out on the device, pull the plug from the electricity socket.
- The device must not be subjected to rain or a direct stream of water.
- The operator is responsible to comply with all regional and national safety and installation reg-ulations and laws. If necessary, ask a qualified electrician.
- If the device should be malfunctioning in any way, any repair work needing to be carried out is only allowed to be done by a qualified technician.
- The device must never run dry or with an entirely closed suction line. The manufacturer is not liable for any damages caused to the device when operated dry, thus the warranty is voided.
Control measures before the first commissioning
- Make sure that the voltage and frequency of the mains current is matching with the technical specifications of the pump (see type label).
- The pump shaft needs to turn freely.
- Fill the system with water, to find any potential leakages and be able to repair them.
- Open all spool valves, which might be present in the pressure and suction line and ensure that all lines are connected.
- Let the water run into the pump via the overflow/ the suction inlet of the pool or fill the suction line and the body of the pump entirely with water.
- Never run the pump dry.
- The pumps are designed for clean water with a max. temperature of 35 ℃; any other use should be avoided.
Mains connection
The electrical connection of the pump needs to be made with a properly
installed earthed socket with a mains voltage of 230 V / 50 Hz.
Assembly
- To avoid long suction lines and loss of performance resulting from it, the pump should be in-stalled at water level or beneath it.
- If a fixed pump unit is used, the electrical pump can be fixed to the floor directly. In this case, use the holes located in the base plate.
- The pumps need to be positioned in a well ventilated and dry area, which additionally is safe from being flooded.
Installing the pipes
- The suction line needs to be vacuum resistant and installed approx. 30 cm beneath water level. This disables the formation of vortexes and thus the inevitable connection of air inflow.
- The pipe connections need to be 100 % air tight. Pipe bends and a wavy layout should be avoided if possible. The suction line should have a minimum gradient of 2 % stretched across the entire length, to ensure no air being trapped in the system.
- The diameter of the pipe being selected for the pressure line, needs to have the same size as the pressure joint of the pump or needs to be even bigger than it.
- The suction and pressure line must under no circumstances be supported by the pump. Make sure that all connections are sealed, so that the pump will not get into contact with moisture and be damaged.
Commissioning
- Fill the system with water, to find any potential leakages, to be able to repair them.
- Open all spool valves, which might be present in the pressure and suction line and ensure that all lines are connected.
- Let the water run into the pump via the overflow/the suction inlet of the pool or fill the suction line and the body of the pump entirely with water.
- Connect the pump to the socket and ensure that the pump allows the water to circulate.
- If the pump is used above water level of the pool, the beginning of the suction hose requires a foot valve, so that the water cannot run out of the suction inlet back into the pool after switch-ing the pump off.
- If the motor does not want to turn on or the water is not being delivered, switch the pump off and disconnect it from the electricity supply and check if there are any blockages in the pipes or in the pump.
- Please do not run the pump without water inside the pump body, as this can damage the me-chanical seals between the pump’s body and motor, allowing the pump to leak.
- Do not carry any work out on the pump or the pipes of the pool system when the pump is op-erating.
- If any problems occur when commissioning the pump, which you are not able to explain or which do not fit the description, please contact a qualified technician.
Maintenance
Our electrical pumps do not require any special maintenance care. Please empty the sediment basket regularly. During colder temperatures and when not being used for longer periods of time, the pump should be emptied out. If the unit will not be used at all for longer durations, it should cleaned and thoroughly swilled out with clean tap water, then dried and stored in a well-ventilated area. Remains of chlorine and other pool supplements can damage the gaskets and cause leakage when operating the pump again.
Technical drawing and data
Model
| ****
Item №
| ****
Energy supply
| ****
Power (W)
| ****
Discharge head (m)
| ****
Suction head
(m)
| Max. flow rate (ℓ⁄h)
---|---|---|---|---|---|---
HCP180| 51554| ****
230 V/50 Hz
| 180| 8| 6| 10,800
HCP250| 51555| 250| 9| 6.5| 11,700
HCP370| 51556| 370| 11| ****
7
| 13,200
HCP550| 51557| 550| 12| 13,800
HCP750| 51558| 750| 13| 15,000
HCP1100| 51559| 1,100| 15| 17,700
HCP1500| 51560| 1,500| 17| 22,500
HCP2200| 51561| 2,200| 18| 26,400
HCP3000| 51562| 3,000| 19| 34,800
Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE,
2012/19/EU) were implemented in the law related to electrical and electronic
equipment and appliances. All WilTec electric devices that fall under the WEEE
regulations are labeled with the crossed-out wheeled waste bin logo. This logo
indicates that this electric equipment must not be disposed of with domestic
waste. The company WilTec Technik GmbH has been registered in the German
registry EAR under the WEEE-registration number DE45283704. Disposal of used
electrical and electronic appliances (intended for use in the countries of the
European Union and other European countries with a separate collection system
for these appliances). The logo on the article or on its packaging points out
that this article must not be treated as normal household waste but must be
disposed to a recycling collection point for electronic and electrical waste
equipment. By contributing to the correct disposal of this article you protect
the environment and the health of your fellow men. Environment and health are
threatened by inappropriate disposal. Material recycling helps reduce the
consumption of raw materials.
Additional information on recycling this article can be provided by your local
community, municipal waste disposal facilities, or the store where you
purchased the article.
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in
part, of this instruction manual require the written permission of WilTec
Wildanger Technik GmbH. © by WilTec Wildanger Technik GmbH
http://www.WilTec.de http://www.aoyue.eu http://www.teichtip.de
The information contained in this document may alter at any time without
previous notice. It is prohibited to copy or spread any parts of this document
in any way without prior written allowance. All rights reserved. The WilTec
Wildanger Technik GmbH cannot be held accountable for any possible mistakes in
this operating manual, nor in the diagrams and figures shown. Even though the
WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless, and up to date, mistakes
cannot be entirely avoided. If you should find a mistake or wish to make a
suggestion for improvement, we look forward to hearing from you.
Send an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in
our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
Do you wish to pick goods up? Our pick-up address is:
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany
To shorten the waiting time and allow for a rapid on-site transaction, we ask
you to call us previously or placing your order via the webshop.
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
To return orders for exchange, repair, or other purposes, please use the
following address. Attention! To allow for a smooth execution of your
complaint or return, it is important to contact our customer service team
before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
References
- Aoyue.de
- Teichtip.de
- WilTec - Ihr Online Shop für Haus, Garten, Werkstatt, Freizeit
- Unternehmen: WilTec Wildanger Technik GmbH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>