Danfoss VIMCC20F Room Thermostat Installation Guide
- June 5, 2024
- Danfoss
Table of Contents
[](https://manuals.plus/wp-content/uploads/2022/07/Danfoss-
logo-4.png)Danfoss VIMCC20F Room Thermostat
Installation
Follow the the illustrations fig. 1 to 6 (dismantling, see fig. 7).
Note , fig. 3: Thermostats can be wired in either BUS or Star
configuration, see Master Controller Installation Guide for more information.
Note , fig. 8: Optional floor sensor requires use of electrical conduit!
Installer Menu
Touch and hold to access the Settings Menu. In Settings Menu, touch and hold
to access the Installer Menu.
Menus
- Range limitation of setpoint for room temperature.
- Info / version number, can be used to identify product.
- Perform Link Test of connection with Master Controller. Returns result as 0-100% (80% or higher is a very strong connection).
- Floor sensor mode:
- Comfort mode. Both air- and floor sensor is used.
- Floor sensor mode. The end user sets desired floor temperature.
- Dual mode. The thermostat controls a radiator and floor heating circuit(s). Floor heating circuits assures min. floor temperature and the radiator is used for peak load.
- Min. and max. temperature for floor, used in and mode.
- Reference Room. Set to ON, if you want this thermostat to be the reference thermostat for switching between cooling and heating.
- Cooling ON/OFF. Use to turn off ability to cool, in e.g. bath rooms.
Menu[](https://manuals.plus/wp-content/uploads/2022/07/Danfoss-VIMCC20F-