Caple CE920WH Ceiling Hood White Glass & Stainless Steel Instruction Manual
- June 5, 2024
- caple
Table of Contents
Caple CE920WH Ceiling Hood White Glass & Stainless Steel
INSTRUCTIONS MANUAL
WARNING
The appliance is not intended for use by young children or infirm persons
without supervision. Young children should be supervised to ensure they do not
play with the appliance.
The extracted air can’t be conveyed through or into a duct used to let out
fumes from appliances fed by energy other than electric power (eg. centralized
heating, radiators, water heaters, etc.).
To evacuate the air outlet, please comply with the pertaining rules given by
competent authorities.
- Provide the room with an adequate aeration when a cooker hood and appliances fed by energy other than electric power (gas, oil, or coal stoves, etc.) are used simultaneously. The cooker hood, when evacuating the extracted air, could generate a negative pressure in the room which can’t exceed the limit of 0.04 mbar, in order to avoid the suck of exhausts deriving from the heat source. Therefore the room should be provided with air-intakes to allow a constant flow of fresh air.
- If the rating label in the cooker-hood does show the symbol the appliance is built in class 11° and it does not need the earth connection.
- If the rating label in the cooker hood does not show the symbol , the appliance is built in class I° and it needs the earth connection.
- When performing the electrical connections on the appliance, please make sure that the current tap is provided with earth connection and that voltage values correspond to those indicated on the label placed inside the appliance itself.
- Before carrying out any cleaning or maintaining operations, the appliance needs to be removed from the electric grid.
- If the appliance is not provided with a non-separable flexible cable and plug, or with another device ensuring omnipolar disconnections from the grid, with an opening distance between the contacts of at least 3 mm, then such disconnecting devices must be supplied within the fixed installation. If the appliance is endowed with a supply cord and a plug, the appliance has to be put in a place where the plug can be reached easily. The use of materials which can burst into flames should be avoided in close proximity of the appliance. When frying, please pay particular attention to fire risk due to oil grease. Being highly inflammable, fried oil is especially dangerous. Do not use uncovered electric grills. In order to avoid possible fire risk, all instructions for grease filter cleaning and for removing eventual grease deposits should be strictly followed.
- This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property.
- The cooker hood is not intended for outdoor use.
- It must only be used as a domestic appliance to extract vapours and remove odours from cooking. Any other usage is not supported by the manufacturer and could be dangerous.
- Where a recirculation cooker hood is fitted above a gas hob, please ensure that there is an adequate supply of fresh air into the room in which it is installed. Please seek the advice of a qualified gas fitter (e.g. GasSafe in the UK) if necessary.
- Children under 8 years of age must be kept away from the cooker hood unless they are constantly supervised.
- Children 8 years and older may only use the cooker hood.
- unsupervised if they have been shown how to use it safely and recognise and understand the consequences of incorrect operation.
- The electrical safety of this appliance can only be guaranteed when correctly earthed. It is essential that this standard safety requirement is met. If in any doubt please have the electrical installation tested by a qualified electrician.
- Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These are a fire hazard and do not guarantee the required safety of the appliance.
- The cooker hood can get very hot during cooking due to heat rising from the hob.
- Do not touch the housing or the grease filters until the cooker hood has cooled down.
APPROPRIATE USE :
- This appliance is intended to be used in household and similar applications such as:
- Staff kitchen areas in shops, offices and other working environments.
- Farm Houses.
- By clients in hotels, motels and other residential-type environments.
- Bed and breakfast type environments.
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. This appliance is marked according to the European directive on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The symbol on the product indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local council, your household waste disposal service or the retailer where you purchased the product.
WARRANTY
Your new appliance is covered by warranty. The warranty card is enclosed – if
it is missing, you must provide the following information to your retailer in
order to receive a replacement: date of purchase, model and serial number.
Registration can also be completed online by visiting
www.caple.co.uk.
Ensure you keep your warranty card safe, you may need to show it to Caple
Service together with proof of purchase. If you fail to show your warranty
card you will incur all repair charges.
Spare parts are only available from Caple Service and spare parts authorised
centres.
CE DECLARATIONS OF CONFORMITY
Radio Equipment Directive (RED) 2014/53/EU.
This Declaration is issued under the sole responsibility of the manufacturer.
Hereby, Caple declares that the radio equipment included in the product is in
compliance with the RED directive 2014/53/EU. The full text of the EU
Declaration of Conformity is available on our website www.caple.co.uk.
UKCA DECLARATIONS OF CONFORMITY
This appliance has been manufactured to the strictest standards and complies
with all applicable legislation.
TECHNICAL FICHE
This appliance conforms to all current and applicable energy regulations. To
view the Technical Fiche that supports the energy labelling data, please visit
the product page on our
website www.caple.co.uk
OPENING THE PANEL
This appliance must be installed with a suitable external motor manufactured by Caple.
NOTE:
The motor does not come included and must be ordered separately.
OPENING THE PANEL
To open the panel which covers the grease filters, pull gently from the side as
shown in Fig.1. They are held inplace by magnets. To work correctly, it is
recommended to install the product at a maximum distance of 2000-2100mm, from
the floor level.Before proceeding with the installation of the appliance, check
that all the components are not damaged, otherwise please contact your
retailer and do not continue with the installation.
Use an air outlet pipe with a maximum length of no more than 5 metres. Keep the number of bends in the duct to a minimum as each bend reduces the suction efficiency equivalent to 1 linear meter. (E.g. If 2 90° bends are used, the length of the duct should not exceed 3 meters in length).
- Avoid abrupt changes of direction.
- Use a duct with a diameter of 150mm constant over the entire length.
- Use a duct of recognized and approved material.
NOTE:
Ducting is not supplied with the product, this is to be supplied by the
installer depending on the installation requirements. For more information on
venting, please see our ‘Extraction & Ventilation guide’ available at
www.caple.co.uk The cooker hood should be placed at
a minimum distance of 65cm above the hob. It is the manufacturer of the hob
who determines the clearance required and the clearance quoted by the hob
manufacturer must be followed. In the absence of any instructions supplied
with a gas hob the minimum distance between the hob and the hood must be at
least 760mm.
INSTALLATION
Take the product out of the packaging and place it on a suitable surface: We
suggest a soft material, such as a sponge or a cloth. Open the glass panel, as
shown in Fig.1, and remove the grease filters.
NOTE:
In order to avoid any possible damage to the glass panel, we recommend to
remove this before installation by unscrewing the eight screws as shown in
Fig.2.
-
Create a recess with a rectangular opening of 865x515mm. The depth can range from 200-280mm.
-
Install the hood onto the ceiling.
-
Install the ducting system for the air outlet to connect to the motor.
-
Make the electrical connection and then complete the plasterboard structure.
-
The recess shall be provided with a socket and a round pipe of 150mm diameter, or a similar section, for the air outlet. Drill the holes on the ceiling as shown in Fig.6.
-
Insert the plastic plugs into the holes made, and then fix the ceiling brackets as shown in
Fig.3. The ceiling brackets are telescopic, so their height can be adjusted at 80mm between the ceiling and the hood. -
Choose one of the three air outlets shown in Fig.4.
-
Fit the spigot to the desired outlet. The remaining outlets shall be closed with the specific metal caps as shown in Fig.4A.
-
Bring the hood close to the brackets previously fixed and then connect the appliance to the supply mains. Secure the hood to the ceiling, by using the screws supplied, as shown in Fig.5.
REMOTE CONTROL
Remote control used for the remote operation of Caple hoods:
TECHNICAL DATA
- Alkaline battery powered: 12V mod. 27A
- Operating frequency: 433.92 Mhz
- Combinations: 32.768
- Max. consumption: 25 mA
- Operating temperature: -20 ÷ + 55 °C
- Dimensions: 120 x 45 x 15 mm
OPERATION
The remote is equipped with 5 buttons for cooker hood management, as specified
below:
Light ON/OFF command.
Motor ON (speed level 1) / OFF command.
Reduce speed.
Increase speed.
10-minute timer.
INITIAL OPERATING CONDITION
The manufacturer supplies the radio control unit ready to be used with preset
codes.
STANDARD CONFIGURATION:
Standard configuration requires all cooker hood remote controls to be provided
with the same
transmission code. In the event two cooker hoods radio control system are
installed in the same
room or nearby, each system may affect the operation of the another.
Therefore, the code of
one radio control system must be changed.
GENERATING A NEW TRANSMISSION CODE:
The radio control system is provided with preset codes. Should new codes be
required, proceed as follows: Press simultaneously buttons:
for two seconds. When LED’s light on, press buttons:
(within 5 seconds). LED’s flashing 3 times indicate the procedure is
completed.
WARNING:
This operation permanently deletes the preset codes.
LEARNING THE NEW TRANSMISSION CODE
Once the transmission code is changed in the remote control unit, the
electronic central unit of the cooker hood must be made to set the new code in
the following way:
Press the main power-off button on the hood and then restore power to the
electronic control unit. Within the next 15 seconds, press the Light Button to
synchronize the central unit with the code.
DIMMABLE LIGHTS FUNCTION
This function dims the cooker hood lights, ranging from 20% to 100%, by
continuously pressing the light key on the remote control.
Functions are the following:
- Hood light off – press the light key – light on at 100%.
- Light on at 100% – press the light key – light off.
- Light on at 100% – continuously press the light key – brightness reduction.
- Releasing the key during reduction or increase – light keeps the luminous intensity reached.
- Light on – dimmed – continuously press the light key – brightness is inverted when compared to the previous function.
RESET OF THE FACTORY CONFIGURATION:
To restore the Factory configuration, follow the procedure described below:
simultaneously press buttons.
for 2 seconds. When LED’s light on, press buttons (within 5 seconds). LED’s flashing 6 times indicate the procedure is completed.
WARNING:
This operation permanently deletes the preset codes.
EMERGENCY BUTTON:
In the event that the remote control does not work, use the emergency button
to switch the appliance off. After any necessary repairs have been performed,
reset the emergency button.
WARNING:
The battery should be replaced every year to guarantee the optimal range of
the transmitter. To replace the battery, take the plastic lid off, remove the
battery and replace it with a new one, observing the correct battery
polarities. Used batteries should be discarded in special collection bins.
WARNING:
Any adjustments or modifications which have not been expressly approved by the
holder of the legal conformity certificate may invalidate the user’s rights
relating to the operation of the device.
The products are endowed with an electronic device which automatically
switches the product off after 4 hours working from the last operation.
TIMING
-
This product is equipped with intelligent electronics which include a timer device for speed controls when the air capacity exceeds 650m³/h. Internal motor models, with maximum air
capacity higher than 650m³/h, are equipped with a timer device that automatically switches the speed from 4th to 3rd speed, after 5 minutes operation. -
External motor models are equipped with remote motors that, as for internal motor versions, include a timer device that switches down the speed when it exceeds 650 m³/h. (See External Motors Instructions). Remote motors, whose air capacity exceeds 650m³/h at both 4th and 3rd speed, will have the following by default timer control functions: The speed is automatically switched from 4th to 2nd speed, after 6 minutes operation.
-
If the appliance is working at 3rd speed, it is automatically switched to 2nd speed, after 7 minutes operation. Operation speeds can also be changed during operation. The energy consumption of the appliance in standby mode is lower than 0.5W.
CLEANING AND MAINTENANCE
- Accurate maintenance guarantees good functioning and long lasting performance.
- Particular care must be made when handling the grease filter. To remove the grease filter, firstly open the glass panel. Then remove the grease filter by pulling its handle. To reinsert the grease filter after cleaning, just perform the opposite operation.
ATTENTION:
After refastening the glass panel make sure that it is properly fixed.
- To clean the appliance itself, tepid water and neutral detergent are recommended, while abrasive products should be avoided. For steel appliances specialised detergents are recommended (please follow the instructions indicated on the product itself to obtain the desired results).
- The LED lights must be replaced only by a qualified person.
REPLACING LED LIGHTING
LIGHT SOURCE ENERGY CLASS
product contains a light source of energy efficiency class F.
The LED light must be replaced by an authorised engineer or similar only. For more information, please contact Caple service – 0117 938 7420 or service@caple.co.uk
- Carefully insert a flat screw driver into the edge of the LED light.
- Remove the LED light from its housing.
- Disconnect the connector and change the LED light.
- Implement the steps in reverse order.
- After waiting 5 minutes, plug in the unit.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>