ECOLAB Foamatic Topax Hygiene System Installation Guide

June 5, 2024
ECOLAB

ECOLAB Foamatic Topax Hygiene System

Placing

The Foamatic unit must be placed in a frost-free room. Free space around the Foamatic unit: min. 1500 mm.

Water supply

Foamatic:

  • Min. 40 l/min.
  • Max. 300 l/min.
  • Pressure: 12-25 bar
  • Max. temperature: 70°C
  • Connection: 1 ¼”

It is recommended to install a closing valve on both in let and outlet immediately before the unit.

Air supply

  • Pressure: 6-8 bar
  • Consumption: 200-450 l/min.
  • Connection: ¼”

Power supply

A single pole main switch should be installed close to the unit.

Voltage:

  • 100-250 V 50 Hz
  • 100-250 V 60 Hz
  • 250-440 V 50 Hz
  • 250-440 60 Hz

Installation

ECOLAB-Foamatic-Topax-Hygiene-System-
FIG-1

Dimensions see fig. 1. It is recommended to mount the Foamatic unit in an appropriate height (approx 2 m to the upper edge from the floor) on a brick or concrete wall. Mount the enclosed wall bracket with the screws and Raw plugs and then secure the Foamatic unit to it.