Thermocold 10182 TCP 6 Polar Cooling Unit Instruction Manual

June 5, 2024
Thermocold

Thermocold 10182 TCP 6 Polar Cooling Unit

Thermocold-10182-TCP-6-Polar-
Cooling-Unit-product

**Safety and usage advisory

**

Please read the following information. If you do not comply with this, damages to persons or equipment may occur, and all warranty and reliability duties will be void.

  • WARNING!
    Risk of fire and electrocution. Risk of damage to persons or cooling unit.

  • WARNING!
    Fire hazard Flammable materials

Intended use

  • This product is designed for private use.
  • The cooling unit must not be placed outdoors. It is not suited for outdoor use even if the area is covered with a tarp.
General safety warnings
  • When the product is worn out, it must not be disposed of as household waste. It must be submitted to an appropriate collection site for recycling EE waste (electric and electronic waste)
  • Contact Thermocold or the nearest service partner for any inquiries and issues with the cooling unit.
  • Do not destroy the cooling circuit where the coolant is circulating using a drill or cutting tool.
  • The refrigerant that may pour out in the event of a puncture may cause skin irritation and eye damage.
  • Do not cover or block the vents of the cooling unit.
  • Repairs to the cooling unit must only be conducted by trained personnel. Repairs conducted by untrained personnel may result in danger to users.
  • Disconnect the power supply during repairs/maintenance on the cooling unit.
  • When unplugging the unit, do not pull the cable.
  • Do not connect the cooling unit if the power outlet is loose.
  • Ensure that the power cable is not crushed or damaged after the cooling unit is installed.
  • Do not connect the plug of the cooling unit to an extension cord.
  • Do not use portable or other external power supplies unless these are approved by Thermocold.
  • Flammable objects or products that contain flammable gases, e.g. spray bottles, as well as explosive materials, must not be stored in refrigerated rooms or corner refrigerators along with the cooling unit
  • Do not use flammable spray materials such as propane gas near the cooling unit.
  • Do not use mechanical equipment or other means to increase the speed of the defrosting process other than such equipment recommended by Thermocold. Make an inquiry to Thermocold or a service partner if you are in doubt.
  • It is dangerous to expose the product to rain, snow, and wind due to electrical safety.
  • Do not spray water directly onto the outer or inner components of the cooling units.
  • Electrical devices must not be used inside the refrigerated room/corner refrigerator unless recommended by Thermocold
  • The label that describes technical specifications is located behind the dust filter drawer in the cooling unit.
  • Children may not play with the cooling unit.
  • Children between the ages of 3 and 8 are permitted to load things into and out of the corner refrigerator/refrigerated room.
  • This cooling unit is not intended for use by persons (including children) with reduced physical, sensory or mental capacity, or a lack of experience and knowledge unless they have received guidance and instruction on the use of the device by a person responsible for their safety.
  • These usage and assembly instructions shall be provided to the next owner of the cooling unit when ownership is transferred.

Disposal of waste product, Compliance with WEEE directive

  • This product complies with the EU directive involving electronic and electrical equipment (2012/19/EU). This product has the classification symbol for the sorting of electrical waste (WEEE).
  • This product is made from high-quality parts and materials that can be re-used and recycled. The product must not be disposed of alongside normal household waste and other waste at the end of its service life. Bring it to a collection point for the recycling of electrical and electronic products. Please consult with local authorities to get information on sorting and collection sites.
  • The packaging for this cooling unit is produced from recyclable materials in accordance with national environmental regulations.

HC warning
The product is equipped with a cooling system that contains the cooling medium R600a: This gas is flammable. Be careful so that the cooling system and pipes are not damaged during use or transport. In the event of any damage, keep the cooling unit a distance away from potential fire sources that may cause ignition. Air out the refrigerated room, corner refrigerator or the premises in which the cooling unit is located. The refrigerant may cause eye damage if it leaks.
Please contact Thermocold for further advice.

Thermocold KFD A/S’ liability does not cover:

  1. Repairs / Actions taken by unauthorized personnel or non-original parts, and the assembly of the device in other installations or products Thermocold does not have control over.
  2. Installation that does not comply with the local electrical safety authority’s provisions and installation instructions.
  3. Use of the cooling unit in violation of the user manual. Inadequate maintenance.
  4. Transport damage not reported to transporter/Thermocold and accidents after delivery that are beyond the control of the provider/dealer, such as lightning strikes, electrical disruptions, and high/low voltage variation beyond indicated voltage.
  5. Improper refrigerated room construction. Poor or inadequate ventilation. Inadequate dust filter maintenance. Corrosion and deposits result from the surrounding environment.

Repairs and compensation:

  1. Thermocold or the dealer may themselves decide between them whether errors or issues should be repaired at the customer location, or at their own or another designated workshop.
  2. The customer is entitled to compensation for financial loss pursuant to the Sale of Goods Act. However, the supplier is not in any circumstances liable for compensation for indirect losses, section 67 (2).
  3. If damage is dealt to objects with a direct or close connection to the product’s use or function, the supplier is only liable to the extent this follows from inalienable legal provisions. This also applies to personal injuries, and injuries of this nature shall be handled in cooperation between the customer and the supplier.

Buyer’s rights

Guarantee

Thermocold guarantees that the product provided has the features and quality described in brochures and other such materials. Small changes due to product changes may occur. The warranty runs 2 years from when the product is delivered to the customer. It is important that the customer follows the use and installation instructions closely. Even in normal use, the product will be subject to wear, necessitating preventive maintenance and thus the replacement of disposable components such as fans, starting equipment for the compressor, thermostats and lights. These are components with variable lifespans depending on installation, use, and maintenance. These are not covered beyond the complaints period of 5 years, but by the warranty in accordance with the Sale of Goods Act.

Consumer purchases:
These terms regulate the customer’s rights with regard to Thermocold as a supplier of new products intended for use in private households. The supplier is obligated to correct errors or flaws, provided the customer has the receipt.

Buyer’s rights:
The deadline for complaints is two years. When the product or parts of the product are intended to last significantly longer, the deadline is five years. All complaints are subject to a requirement that the defect was present at the time of delivery. However, the customer will lose the right to raise a complaint if they do not complain within a reasonable time frame after the flaw is discovered or should have been discovered. In the event of flaws subject to sales legislation, Thermocold retains the right to repair the product within the deadline in accordance with the Sale of Goods Act.

Trade purchases
Trade purchases are all purchases not made by consumers. If the product is located in cafés, restaurants, street kitchens, hotels, motels, businesses with other commercial activities, or in schools, institutions, dormitories, kindergartens, sports facilities, shared households and where the customer fully or partially pays for the use of the product or in a rental situation, as well as if the product is used to preserve a product the customer sells. The complaint period and warranty period will then be 1 year. This applies to any losses the flaw may cause due to, e.g. operational losses, lost profits and other consequences involving financial losses. This limitation to the supplier’s responsibility does not apply if the customer has been found grossly negligent. In general, the terms and conditions for consumer purchases apply. Thermocold makes reservations for potential printing errors and retains the right to change any product specifications.

Read before assembling the cooling unit

  • Wait for two to three hours after assembling the cooling unit to the wall before starting it. This is done because the oil for the compressor must first run back.
  • Check that the copper pipes are not in contact with metal or plastic, this also applies to the hose in the plastic tub.
  • Make sure that the drainage tube is in the bottom of the evaporation tray.
  • Connect the plug and check that both the fans and the compressor are running normally.

Thermocold cooling units are assembled from the refrigerated room side through the wall to the warm side. This provides much greater flexibility with regard to assembly solutions. A stable, appropriate cold room is contingent on appropriate insulation in the floor/ceiling/walls, and the ambient temperature on the warm side of the cold room remains 16 to 27°C. These are the most optimal operating conditions, causing the least wear. It is important that the cooling unit has a good supply of fresh air and that the room in which it is installed is well-ventilated. All walls adjacent to the cold room/corner refrigerator should be insulated. The cooling unit requires a voltage of 220-240V and a minimum 10A grounded fuse. The plug can be installed to the warm or cold side of the cooling unit. Use a label when placing the plug within the plastic cover or ventilation grates. Ensure that a physical barrier/air barrier or air vent is used to separate intake and exhaust from the fan on the warm side. This is so that the warm air can be removed and replaced by cooler fresh air. See assembly alternatives 1-7 to see what is required for your assembly alternative. The Winter operations kit should be installed in temperatures below +16°C.

Energy saving and food storage
Thermocold products place a strong focus on the best possible storage of food and raw ingredients in corner refrigerators and cold rooms.

Energy-saving measures:

  • If the door stands open, this will increase running hours and energy consumption.
  • Good tidiness is required for the air to circulate properly.

Tips for storing food:
The temperature will vary from bottom to top. This is because food goods will best be stored at different temperatures. Proper storage is essential for preserving taste and for maintaining the shelf life of food goods.

In short, we recommend the following:
Milk, meat, and bread topping products shall be placed so that there is proper circulation around the products, allowing for quicker cooling. Vegetables that contain a lot of water should be packed in plastic or freezer bags, e.g., carrots and cucumbers. We recommend placing other vegetables in plastic containers with lids. This also applies if you store fruit such as apples, oranges, salad and tomatoes. Potatoes should be kept in light-proof sacks or in light-proof boxes with lids. This is to protect the goods from cold circulating air and to provide additional protection against the loss of moisture, in addition to the plastic packaging. As maintaining good hygiene in the room is important, the walls have a food-safe protective surface, reducing bacterial growth and making it easier to clean surfaces.
A full overview of the storage of the most common products can be found on Thermocold’s website.

Adjusting the temperature of the cooling unit

Temperature can be set from 3 – 20 °C. The operating display indicates the room’s air temperature. When it is set to 4°C, the displayed temperature will vary by +/- approx. 2.5°C Place a thermometer in a glass of water to measure the temperature of the food goods.Thermocold-10182-TCP-6-Polar-Cooling-Unit-
fig-1

Temperature adjustment:

  1. Press “up” to increase the temperature
  2. Press “down” to decrease the temperature
  3. Wait 10 seconds. The new temperature has now been set.

Manual defrosting:
Use manual defrosting if a mass of ice has built up on the heat sinks of the cooling unit. Duration 30 minutes.

  1. Press “manual defrosting” for 6 seconds to activate manual defrosting.
  2. Press “manual defrosting” for 6 seconds to deactivate manual defrosting.

On/Off Standby mode:
Use Standby mode when you want to turn off cooling on the cooling unit.

  1. Press and hold “On/Off” for 10 seconds to deactivate cooling on the cooling unit
  2. Press and hold “On/Off” for 10 seconds to activate cooling

Parameter settings: (Intended for service technician)

  1. Press “up/down” and hold for 5 seconds to access the parameter menu.
  2. First parameter group is displayed as “tHE”
  3. Press “up/down” to find the desired group
  4. Press “OK”
  5. The first parameter is displayed
  6. Press “up/down” to find the desired parameter
  7. Press “OK”
  8. Press “up/down” to find the desired setting.
  9. Press “OK”

The display will automatically return to the indicated temperature after 30 seconds, or after you press “back” twice.

Dimensions and technical specifications TCP 6

PolarThermocold-10182-TCP-6-Polar-Cooling-Unit-fig-2

  TCP 6
Light aperture in-wall installation 440×740
Minimum distance from the ceiling to top of the light aperture 80mm
 
Minimum air volume 200cm²
Climate class T
Ambient temperature 15-43°C
 
Voltage: 220-240V 50Hz
Amperage draw: 1.46 A
Net weight 27 kg
 
Cooling capacity (W / Litre) 390W/ 8000 litres
Refrigerant R600a 106g
 
Automatic defrosting YES
Condensation drain YES
Dust filter YES
 

Cleaning and maintenance

The consumer is responsible for conducting cleaning and maintenance on the cooling unit. This is required to maintain a warranty.

Dust filter cleaning
Clean the dust filter of the cooling unit every 3 months or more frequently where needed. Loosen the dust filter drawer (2), pull out the dust filter frame (2), and vacuum the sheet to clear it of dust.

Cleaning cold room/corner refrigerator
To prevent mold growth, it is important to regularly clean the cold room. Use mild soap and dry using a damp cloth.Thermocold-10182-TCP-6-Polar-Cooling-
Unit-fig-3

  1. Thermostat
  2. Dust filter / Dust filter drawer
  3. Condenser
  4. Condenser fan
  5. Evaporator fan
  6. Evaporator/heat sink
  7. Compressor
  8. Evaporation basin
  9. Condensation drainpipe. The rubber gasket on the inside of the cover
  10. Condensation drain/overflow drain.

Troubleshooting and service

Issue Cause Needs Action
Poor cooling The dust filter is clogged Clean dust filter To be

corrected by the user
 | The ambient temperature is too high| Improve ventilation| To be corrected by the user
 | Condenser fan defect| Replace fan motor| To be corrected by a service partner or trained personnel. Contact Thermocold or service

partner to purchase parts

 | The evaporator is clogged with ice| Manual removal| To be corrected by the user
 | Lack of air barrier| Install air barrier| To be corrected by the user/service partner. Contact Thermocold or service partner to purchase

parts.

 |  |  |
No cooling| The compressor is not running| Check fuse| Contact Thermocold or a service partner
 | Thermostat set to Standby mode| Deactivate standby mode| To be corrected by the customer
 |  |  |
Water pouring over the front end of the

unit.

| The drainpipe for condensed water is clogged| Poke up a drainpipe for condensed water with a 35-cm

length of wire

| To be corrected by the customer
 | The door has been left open| Close the door| To be corrected by the customer
 | Magnetic seal of cold room door does not seal against frame/wall| Adjust the door so that it seals against the frame or wall.

Use magnetic seal if necessary.

| To be corrected by customer/service partner. Contact Thermocold or service

partner to purchase parts.

 | The sealing gasket around the cooling unit is unsealed or worn out.| Ensure that the gasket seals all around between the cooling unit and the wall.

Change the gasket if necessary.

| To be corrected by customer/service partner. Contact Thermocold or service

partner to purchase parts

 | Air leaks into a cold room or corner refrigerator.

In the event of high humidity, this occurs more often.

| Check that all seals in the walls, ceiling, and floor are sealed. Inspect the magnetic seal of the door and sealing gasket around the cooling unit.

Seal joints with silicone. Replace sealing gasket and/or

magnetic seal if necessary.

| To be corrected by customer/service partner. Contact Thermocold or service partner to purchase parts
 |  |  |
Water out of drainage pipe| The door has been left open| Close the door| To be corrected by the customer
 | Air leaks into a cold room or corner refrigerator.

In the event of high humidity, this occurs more often.

| Check that all seals in the walls, ceiling, and floor are sealed. Inspect the magnetic seal of the door and sealing gasket around the cooling unit.

Seal joints with silicone. Replace sealing gasket and/or

magnetic seal if necessary.

| To be corrected by customer/service partner. Contact Thermocold or service partner to purchase parts
 |  |  |
Vibration or noise| The plastic edge of the cooling unit is in contact with the wall of the cold room| Loosen the cooling unit so that the sealing gasket, rather than

the plastic edge of the cooling unit, is in contact with the wall.

| To be corrected by customer/service partner
 | Evaporator or condenser fan imbalanced| Replace fan motor| To be corrected by a service partner or trained personnel.

Contact Thermocold or service partner to purchase parts

 | Condenser fan defect| Replace fan motor| To be corrected by a service partner or trained personnel. Contact Thermocold or service

partner to purchase parts

For service needs, contact:

  • Thermocold KFD AS service department Tel. +47 69 10 24 00
  • Local service partner/dealer: See the Thermocold website www.thermocold.no
  • Have the serial number at hand. This can be found behind the dust filter drawer (point 2 under cleaning and maintenance).

Equipment list installation option

 | Type of cooling unit| Plastic cover

/ Plastic cover for modular

room

| Metal air vent| Ventilation grates| Insulating strip| Air barrier short (55cm)| Air barrier long (240cm)
---|---|---|---|---|---|---|---
Alt. 1| TCP 6|  |  |  |  |  | X
__| Air barrier long 240 cm
---|---

Installation alternative 6 – Corner refrigerator with air vent/air

barrierThermocold-10182-TCP-6-Polar-Cooling-Unit-fig-5

  1. Ensure that the hole in the modular wall is 440×480 mm Distance from the ceiling to the top of the light aperture minimum of 80 mm. Minimum airflow between grates 200 cm²

  2. Install the plug 2200mm from the floor and up, and 800mm from the corner and out.

  3. NB! Must be conducted by an authorized electrician.

  4. If an air conduit going from the floor to the ceiling has not been installed on the rear wall, an air barrier must be installed. See figure

  5. You must install/there must be installed 1 ventilation grate at the base and 2 ventilation grates over the door in a kitchen with a high ceiling.

  6. Lift the cooling unit into the cooling corner. Let it rest on the floor or a shelf. The main cable is pushed up and out over the air duct and is fastened so that it cannot slip down into the air duct again. Do not connect the plug to a socket

  7. Push the cooling unit in and fix it with screws in each corner. The gasket should seal against the wall.

  8. Connection to existing lighting:

  9. Loosen the set screw

  10. Squeeze the locking hook together and lift the lid

  11. The cables are connected to N and L.

  12. Fasten the cable under the strain reliever

  13. Squeeze the lid back in place and screw in the set screw.
    The connection for illumination is at the top of the cooling unit. The outlet provides 12V LED When connecting a spotlight with a G4 bulb type: The light source must be switched to the bulb type: LED 12V G4 0.9W. When connecting an LED rail along the door No measures are necessary.

  14. Connect the plug to the outlet and make sure the unit starts up.