Please read this manual before use and follow its guidance. Keep this manual for future reference
Introduction
Thank you for purchasing Sub Panel by BLUETTI. Sub Panel is designed and
developed by BLUETTI for household power storage intended to supply electrical
power to home appliances, RVs, or remote locations where utility power is
unavailable or in place of a utility due to a power outage. The Sub Panel is
compatible with installations in the United States, Canada, Mexico, Japan, and
other countries.
The EPS00(or AC300) + Sub Panel power system adopts environmentally friendly
and safe lithium batteries and provides users with a longer and more stable
backup power supply.
The user manual contains safety information to make you aware of hazards and
risks associated with Sub Panel and how to avoid them, and instructions about
installation, operation, and maintenance. You must read these instructions
thoroughly before starting or operating this equipment. Save this original
instruction manual for future reference.
1.1 Features
- Indoor & Outdoor Installation.
- Compatible with BLUETTI AC300 and EPSOO/Pro.
- Support single and dual EPSOO/Pro or AC300 connected to generate power at 120V or 240V.
- Features inspection function. When the Sub Panel is required to be over-hauled, the load on Sub Panel can be powered via the grid.
- Safety is ensured, and Sub Panel will prevent overloads.
1.2 Application
For users with Single EPSOO/Pro or AC300, please connect the load to SubPanel.(Chapter 3.1) For users with Dual EPSOO/Pro or Dual AC300s, installation and enabling split phase function. (Chapter 32
1.3 In The Box
The user must contact the dealer if the unit is defective.
| Unit| Quantity
---|---|---
A| Sub Panel| 1
B| User Manual| 1
C| Certification Card| 1
Figure 1.1 Package List
1.4 Quality Inspection
Check the unit before shipping.
Content | Requirement |
---|---|
Appearance Inspection | Complete |
Hardware | Complete |
Accessories | Complete |
Figure 1.2 Quality Test
1.5 Sign
| DANGER: The risk and severity of the shock depend on the voltage.
---|---
| WARNING: May cause personal or equipment damage.
1.6 Safety
The user manual contains safety information to make you aware of hazards
and risks associated with Sub Panel and how to avoid them, and instruction
about installation, operation, and maintenance.
It is essential to read and understand these instructions thoroughly before
attempting to start or operate this equipment.
Installation
2.1 Preparation
2.1.1 Tool
Tools for installation of Sub Panel
No. | Tool | Procedure |
---|---|---|
1 | Drill | Preinstallation |
2 | Screw (4 PCS) | Installation |
3 | Wire strippers✓Bolt cutter | Wire |
4 | Screw Driver(1 Set) | Wire |
Figure 2.1.1 Tool Requirement
2.1.2 Wire
The wires connecting the home circuit to the Sub Panel are required as the
chart below. The length and size of the cables are determined according to
your needs and actual installation environment
Wire | Size (recommendation) | Color (recommendation) |
---|---|---|
Hot (L1) | a8AWG | Black |
Hot (1.2) | a8 AWG | Black |
Neutral (N) | ae AWG | White |
Earth (PE) | ae AWG | Green |
WARNING: The AC cable should meet the requirements of the National |
Electrical
---|---
2.2 Installation
The cable for connecting AC300 or EP500 series with Sub Panel contained in the
package, please follow the instruction.
- Take out the screw from the front cover of Sub Panel and remove it as Figure 2.2
- Drill into the wall according to the size of Sub Panel. Type A – Mounting: 4PCS Expansion Screw for concrete wall, tapping screw for wooden. Type B – Hanging: 2PCS Expansion Screw for concrete wall, tapping screw for wooden.
- Mount the Sub Panel. Mount the Sub Panel on the wall from the pre-bored holes.
2.3 Sub Panel Wiring
Please follow the next steps after you have properly mounted the Sub Panel.
DANGER: Please use insulating tools during installation and maintenance.
DANGER:
•Turn off all breakers before installation, and twist the main switch to “0”.
•Confirm that your panel is no longer energized by utility power.
WARNING: The AC cable should meet or exceed the requirements of National
Electrical Standards.
23.1 Wiring to Grid
- Determine the length of the connecting wire according to the distance from the Sub Panel to the Main Panel.
- Connect the Line Wires and Neutral Wires to the circuit breaker’s wiring bar on Sub Panel.
2.32 Circuit of Load
- Determine the length of the connecting wire according to the distance from the Sub Panel to the Main Panel.
- Connect the Line Wire, and Neutral Wire to the circuit breaker, and bus bar on Sub Panel as Figure 2.5.
2.33 Wiring to BLUETTI Power Station
For better convenience, the connecting cables for EPSOO/Pro or AC300
(according to your order) are involved in the package of Sub Panel. Please
turn to Chapter 3 for detailed installation information. Check the connection
as (Circuit Diagram 1), but the front cover back.
Connection
Sub Panel supported Single or Dual BLUETTI Power Station connection.
Compatible Model: EPSOO/Pro, AC300.
Please contact the dealer whether you order the Sub Panel Version that is
compatible with your power station.
**| DANGER:
Read the user manual before installation.
---|---
**| WARNING:
Ensure Sub Panel and the circuit is turned off.
3.1 Single Connection
For single EPSOO/Pro or AC300 power station.
Grid : 2-wire input from the grid at single-phase 100V or 120V is
recommended.
The load capacity should exceed the Max Power of Input of the Power Station.
3.1.1 Single EP500
Cable involved in the package of Sub Panel to connect with EP500.
Connection
of single EP500 with Sub Panel
Cable involved in the package of Sub Panel to connect with EP500 solar power
station.
WARNING: The Input and Load circuits have to be connected to the same Line
Wire.
3.1.2 Single EP500 Pro
Cable involved in the package of Sub Panel to connect with EPSOOPro solar
power station.
Connection of single EPSOOPro with Sub Panel
WARNING: The Input and Load circuits have to be connected to the same Line Wire.
3.1.3 Single AC300
Cable involved in the package of Sub Panel to connect with AC300 solar power
station.
Connection of single AC300 with Sub Panel WARNING: The Input and Load circuits have to be connected to the same Line Wire.
3.2 Split Phase Connection System
For Dual EP500/Pro or Dual AC300 to enable Split Phase System. Grid: 3-wire
input from the grid at single-phaselOOV or120V is recommended. The load
capacity should exceed the Grand Max Power of Input of the Power Station.
32.1 Dual EP500
Cable involved in the package of Sub Panel to connect with Dual EP500 solar
power station.
WARNING: The Input and Load circuits have to be connected to the same Line
Wire.
3.2.2 Dual EP500 Pro
Cable involved in the package of Sub Panel to connect with Dual EP500- Pro
solar power station.
WARNING: The Input and Load circuits have to be connected to the same Line
Wire.
Operation
Sub Panel supports manual bypass conversion function for maintenance, When you
want to remove the EP500/Pro, AC300 Power Station from the Sub Panel, please
tweak the rotary switch on Sub Panel to “2” (Figure 4.3) to maintenance then
disconnect the connecting cable on Power Station,-the household load will be
powered directly by the utility power.
4.1 Pass-through Function
Rotary Switch Status: “O”: Disconnect. Loads on Sub Panel are disconnected
from both the utility power and Power Station. (Figure 4.1)
“1”: Connected. Sub Panel functions are all enabled. (Figure 4.2)
“2”: Grid power supply. The grid power supply status bit is directly supplied
by the grid household load, which can complete the charging function for
matching products.(Figure 43)
4.2 Grounding Method
FLOATING NEUTRAL: When Sub Panel is connecting with BLUETTI Power Station
only(Disconnected with Main Panel): AC300, EP500, and EP500Pro, the N and PE
Wire of the Input Port and Output Port of Power Station are not connected to
Sub Panel directly, the distribution system’s neutral conductor will “float”,
which means they are floating neutral.
BONDED NEUTRAL: Connecting the Sub Panel to BLUETTI Power Station will not
switch the floating neutral to bonded neutral. If you want to convert the Sub
Panel to bonded neutral, please connect the Sub Panel with Main Panel, or
follow the instruction to connect the Neutral bus bar to PE.
Connect
AC1 and LOAD1 to one device, and AC2 and LOAD2 to another device.
Specifications
Specifications
Working Temperature| 0°C-45°C/32-113°F
Humidify| 10%-90%
Altitude| <2000m
Dimension (LWH)| 360140600mm/14.175.51*23.62in
Weight| 17KG/37.4Ibs
Maintenance
Please follow the recommendations below for regular maintenance of the Sub
Panel:
Check the wiring of each part of the system regularly to whether the
connection is stable.
Cut off the power immediately if it is loose. Please tighten it after powering
off.
Regularly check the components for issues of vibration, abnormal sound or
smell, etc.
The clean exterior cover of Sub Panel regularly.
Regularly check whether the wires of each part are integrated into Sub Panel,
damaged wires should be replaced immediately.
Please contact the dealer if the issues are not able to solve, a detailed
record of the problems will help.
Copyright
BLUETTIPOWERINC
Declaration
Our company will not bear all responsibilities if the damage is caused by
improper operation of the product.
Our company shall not be liable for any damage caused by force majeure such as
fire, typhoon, flood, earthquake, or the user’s intentional negligence,
misuse, or other abnormal conditions.
Some changes may not be explicitly noticed, such as appearance or
specifications due to the exterior material and hardware improvement.
Version
A 21 Version.
Date: Feb. 2022
Company: POWEROAK GmbH
Address: Lindwurmstr. 114, 80337 Munchen Germany
Mail: logi@bluetti.de
Company POWEROAK ENERGY UK CO., LTD
Address: Suite 108 Chase Business Center 39-41
Chase Side London United Kingdom N14 SBP
Mail:poweroak.eu@bluetti.com
P/N:17.0303.0391-01A1
Documents / Resources
|
BLUETTI EP500 Solar Power
Station
[pdf] User Guide
EP500, Solar Power Station, EP500 Solar Power Station, Power Station, Station
---|---
|
BLUETTI EP500 Solar Power
Station
[pdf] User Guide
EP500 Solar Power Station, EP500, Solar Power Station, Power Station
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>