SciCan STATIM B G4+ Vacuum Autoclave User Guide

June 5, 2024
SciCan

SciCan STATIM B G4+ Vacuum Autoclave

SciCan STATIM B G4+ Vacuum
Autoclave product

BASIC OPERATION

  1. Power unit ON. SciCan STATIM B G4+ Vacuum Autoclave fig 1
  2. Fill with demineralised/distilled water.SciCan STATIM B G4+ Vacuum Autoclave fig 2
  3. Load configurations.SciCan STATIM B G4+ Vacuum Autoclave fig 3
  4. Close unit.
  5. Run cycle.SciCan STATIM B G4+ Vacuum Autoclave fig 5
  6. Open unit. SciCan STATIM B G4+ Vacuum Autoclave fig 6
  7. Unload instruments. SciCan STATIM B G4+ Vacuum Autoclave fig 7

TOUCHSCREEN

SciCan STATIM B G4+ Vacuum Autoclave fig
8

MAINTENANCE SCHEDULE

  • Daily
    • Wipe the drawer seal.
    • Clean external surfaces.
  • Weekly
    • Clean the chamber and trays.
    • Drain water reservoir.
    • Disinfect external surfaces.
    • Inspect and clean the chamber filter (or replace if necessary).
  • Every 2 Years or 2,000 Cycles
    • A complete maintenance of the autoclave including testing of the pressure relief valve and the power failure mode (by a SciCan-approved technician) is recommended.
  • Monthly or 160 Cycles
    • Inspect the water reservoir filter (clean or replace).
    • Clean the external fill water tank.
  • Every 6 Months or 1,000 Cycles
    • Perform all monthly cleaning tasks.
    • Replace bacteriological air filter.
    • Replace drawer seal.

**WARM-UP MODE

SciCan STATIM B G4+ Vacuum Autoclave fig
9**

  • STAND-BY LOW – For low to average use: 70°C / 158°F
  • STAND-BY HIGH – For high use: 120°C / 248°F
  • STAND-BY OFF (default) – For infrequent use. The wait time will be longer (up to 12 minutes from a cold start)

INSTRUCTIONAL VIDEOS

SciCan STATIM B G4+ Vacuum Autoclave fig
10

LED COLOUR

SciCan STATIM B G4+ Vacuum Autoclave fig 11

LOCK ICON

SciCan STATIM B G4+ Vacuum Autoclave fig
12

Spare Parts and Accessories

  • 01-116292S
    • Air Filter
  • 01-116293S
    • Drawer Seal, 6L
  • 01-116294S
    • Tray, 6L
  • 01-116296S ‘
    • Exhaust Tube
  • 01-116297S
    • Extended Exhaust Tube
  • 01-116298S
    • Direct-to-Drain
  • 01-116299S
    • Water Filling
  • 01-116300S
    • Waste Bottle
  • 01-116301S
    • USB Memory Stick
  • 01-116302S
    • Water Reservoir Cap
  • SCI-BDSK134V
    • Bowie-Dick Test Kit
  • 97902001
    • Helix Test Kit with 100 Chemical Indicators
  • 97902002
    • Helix Text Kit with 400 Chemical Indicators
  • 01-110282S
    • Power Cord EU 16A/250V
  • 01-110285S
    • Power Cord UK IND plug 16A/250V
  • 01-116496
    • StatMat Silicone Mat STATIM B
  • 01-116497S
    • Reservoir Chamber Filter
  • 01-116498S
    • Pouch Rack Kit

IMPORTANT!
Users of this device must be sure to select the most appropriate sterilization cycle according to the recommendations of the leading infection control authorities and local regulatory guidelines/recommendations.