SODECA UNIREC High-Efficiency Single-Zone Heat Recovery Ventilators Installation Guide
- June 5, 2024
- SODECA
Table of Contents
UNITEC High-Efficiency Single-Zone Heat Recovery Ventilators
High-efficiency single-zone heat recovery ventilators for domestic installations.
Designed to renew the air inside the home while minimizing energy loss, and to supply clean air, due to their filters, which prevent particles from entering from outside.
Features:
- Reversible EC fan.
- Thermal efficiency of 90%.
- Equipped with G3 filters.
- Compact ceramic heat exchanger.
- Easily installed, the telescopic duct means that they are suitable for several wall thicknesses.
- Automatic air intake grille; in the OFF position, it remains closed to prevent air leakages.
- In heat recovery mode, the supply and extraction cycle takes 70 seconds.
- Duct length from 120mm to 470mm.
Control:
- Control panel built into the system.
- Remote control.
- Extract, blow o heat recovery.
- Two speeds.
- Humidity control.
- Natural mode, air intake grille open and fan stopped.
- Option of connecting several machines in a network.
Motor:
- Supply voltage of 100V to 230V, 50/60Hz.
- Built-in power cable.
Order code
Technical characteristics
Model| Fans| Input
Voltage (V)| Frequency
(Hz)| Maximum
airflow
(m3/h)| Thermal
efficiency
(%)| LpA
radiated 3m
dB(A)| Temperature
of air transported
(ºC)| Diameter
of duct (mm)| Length
of duct
(mm)
---|---|---|---|---|---|---|---|---|---
Speed (r/min)| Current
(A)| Power
(W)
UNIREC-35-S| 1670| 0.032| 5.1| 1×100-230| 50/60| 30| 90| 28| -20 a +50| 125|
120-470
UNIREC-50-S| 1450| 0.039| 5.61| 1×100-230| 50/60| 54| 90| 23| -20 a +50| 150|
120-470
Dimensions in mm
Working cycles in recovery mode
EXTRACTION (70 seconds) | SUPPLY (70 seconds) |
---|---|
During this cycle, the ceramic heat exchanger absorbs heat from the extracted
air.| During this cycle, the heat exchanger provides heat to the air coming in
from the outside.
Once this cycle has finished, the process of extraction starts again, and so
on.
Example of equipment installation
A: Machines working individually in heat recovery mode for a single room.
B: Machines working in a network, synchronized; while one performs the supply
cycle, the other performs the extraction cycle, and so on.