Altronix T2KK38 8 Door Kit with Fused Outputs Installation Guide

June 3, 2024
Altronix

Altronix T2KK38 8 Door Kit with Fused Outputs

T2KK38

8 Door Kit with Fused Outputs Fully assembled kit includes:

  • Trove2 enclosure with TKA2 Altronix/Keyscan backplane
  • (1) AL600ULXB – Power Supply/Charger
  • (1) ACM8 – Fused Access Power Controller
  • (1) T16100 Transformer

T2KK38D

8 Door Kit with PTC Outputs Fully assembled kit includes:

  • Trove2 enclosure with TKA2 Altronix/Keyscan backplane
  • (1) AL600ULXB – Power Supply/Charger
  • (1) ACM8CB – PTC Access Power Controller
  • (1) T16100 Transformer

All components of these Trove kits are UL Listed as sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

Overview

Altronix Trove Keyscan kits are pre-assembled and consist of Trove2KA2 enclosure/backplane with factory installed Altronix power supply/charger, transformer, and sub-assemblies. These kits also accommodate various combinations of Keyscan boards for up to eight (8) doors in a single enclosure.

Configuration Chart




Altronix Model Number

| ****

115VAC

60Hz

Input Current (A)

| Power Supply Board Input Fuse Rating| Power Supply Board Battery Fuse Rating| Nominal DC

Output Voltage Range (V)

| Maximum Supply Current for Main and Aux.

Outputs on Power Supply board and ACM8/ ACM8CB Access Power Controller’s outputs (A)

| Fail-Safe/ Fail-Secure or

Dry Form “C” Outputs

| ****

Fail-Safe/ Fail-Secure Outputs (auto- resettable)

| ****

Current Per ACM8

Output (A)

| ****

Current Per ACM8CB

Output (A)

| ACM8/ ACM8CB

Board Input Fuse Rating

| ****

ACM8

Board Output Fuse Rating

| ****

ACM8CB

Board Output PTC

Rating

---|---|---|---|---|---|---|---|---|---|---|---|---
T2KK38| 3.5| 5A/

250V

| N/A| 20.19-

26.4

| 24VDC @ 5.8A| 8| –| 2.5| –| 10A/

250V

| 2.5A| –
T2KK38D| 4.2| 5A/

250V

| 15A/

32V

| 20.17-

26.4

| 24VDC @ 5.8A| –| 8| –| 2.0| 10A/

250V

| –| 2A

Installation Instructions

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.

  1. Remove the backplane from the enclosure. Do not discard hardware.

  2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.

  3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure, approximately 2” from the right side (Fig. 1, pg. 2).
    Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.

  4. Mount Paxton Net2 Plus modules to TPX2 backplane, refer to page 3.

  5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NB and corresponding Sub-Assembly Installation Guides for the following models: ACM8(CB), PDS8(CB) and VR6 for further installation instructions.

Hardware

T2KK38(D) Configuration of Keyscan Boards

  1. Mount appropriate Keyscan boards into the correct positions (Fig. 2, pg. 2) by postioning spacers over appropriate holes in the backplane and depressing down on board to secure spacer to the backplane (Fig. 2b, pg. 2).
  2. Fasten backplane to Trove2 enclosure utilizing pan head screws (provided). Altronix-T2KK38-8-Door-Kit-with-Fused-Outputs-FIG-0

Enclosure Dimensions

27.25” x 21.5” x 6.5” (692.15mm x 546.1mm x 165.1mm)

Altronix-T2PXK7F8-8-Door-Kit-with-Fuse-d-Outputs-FIG-5

Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITrove PX Kits

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals