Danfoss 088R0400 Icon 2 Main Controller User Guide

June 5, 2024
Danfoss

Danfoss-logo

Danfoss 088R0400 Icon 2 Main Controller

Danfoss-088R0400-Icon-2-Main-Controller-image

SPECIFICATION

  • Max. number of thermostats: 15
  • Max. number of actuators: 15
  • Internal fuse: 2 A
  • Conforms with directives: LVD, EMC, RoHS, WEEE, RED
  • Storage temp. range: −20 °C to +60 °C
  • Output relay, boiler: Voltage free, max. 2 A, max. Voltage 230 V~
  • Input 1 &2, Setback / Cooling: Voltage free
  • Rated impulse voltage: 4 kV
  • Temperature for ball pressure test: 75 °C
  • Control pollution degree: pollution degree 2
  • Disposal instructions: As electronic waste
  • Operating time: permanent connection
  • Purpose of control: Individual electronic room temperature control
  • Protection class: Class II with earthing terminal
  • Control action type: 1 b
  • SELV level: 24V circuits are Safety Extra Low Volatge Software Class: A

Danfoss-088R0400-Icon-2-Main-Controller-fig1

SIMPLIFIED EU DECLARATION OF CONFORMITY

Hereby, Danfoss A/S declares that the radio equipment type Danfoss Icon2 MC are in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: heating.danfoss.com

Need help? Download App

Danfoss-088R0400-Icon-2-Main-Controller-fig2

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals