Altronix POE60 Power Supply-Charger Board
Overview
Altronix POE60 provides 75W for NetWay Spectrum switches with 1Gb SFP ports. It converts 115VAC, 60Hz or 230VAC, 50Hz input into a 56VDC at 1.3A of continuous supply current (see specifications). It also features a optimized built-in charger for Lithium Iron Phosphate type batteries.
Specifications
Input:
Universal Input 115VAC, 60Hz, 2.5A or 230VAC, 50Hz, 1.3A.
Output:
- 56VDC/75W output.
- 1.3A continuous supply current.
- Filtered and electronically regulated output.
- Short circuit and thermal overload protection.
Battery Backup:
- Built-in charger for Lithium Iron Phosphate type batteries.
- Automatic switch over to stand-by battery when AC fails.
Features:
- Input voltage selection switch.
- Includes battery leads.
Board Dimensions (L x W x H approx.):
7” x 4” x 1.375” (177.8mm x 101.6mm x 34.9mm).
Installation Instructions
POE60 should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
-
Mount POE60 in the desired location/enclosure. Pay attention to correct positioning of the board, depending on Altronix product being serviced. Mounting hardware included.
-
Set POE60 to the proper AC input voltage via input voltage switch (Fig. 1).
-
Connect AC power from overcurrent protective device circuit breaker (20A @ 115VAC, 60Hz, 16A @ 230VAC, 50/60Hz) to the terminals marked [L, N] on power supply board (Fig. 1). Use 14AWG or larger for all power connections (Battery, DC output, AC input). Keep power-limited wiring separate from non power-limited wiring (115VAC/230VAC 50/60Hz Input, Battery Wires). Minimum 0.25” spacing must be provided.
CAUTION : Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts on unit. Refer installation and servicing to qualified service personnel. -
Measure output voltage before connecting devices. This helps avoiding potential damage.
-
Connect devices to be powered to the terminals marked [– DC +].
-
When the use of stand-by batteries is desired, they must be Lithium Iron Phosphate (LiFePO4) type batteries. Connect batteries to the terminals marked [– BAT +] (battery leads included).
-
When batteries are not used, a loss of AC will result in the loss of output voltage.
Terminal Identification
- Terminal Legend Function/Description
- L, G, N Connect 115VAC/230VAC to these terminals L to Hot, N to Neutral.
- DC + 56VDC @ 1.3A continuous supply current.
- BAT + Stand-by battery connections. Maximum charge rate 0.7A.
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com |