PHILIPS BN398X Green Perform Batten
Mounting instruction
Type
| CRI| Power ( W)
| Lumen
| CCT
| Light source energy
efficiency class
| Optics
| Voltage
| Hz
| KG
---|---|---|---|---|---|---|---|---|---
BN398X LED20 L600 L1 S OP| 80| 15| 2200| 3000/4000/6500| D| OP| 220-240V~|
50/60Hz| 1
BN398X LED40 L1200 L1 S OP| 80| 26| 3700| 3000/4000/6500| D| OP| 220-240V~|
50/60Hz| 1.7
BN398X LED20 L600 L1 S WB| 80| 13.5| 2000| 3000/4000/6500| D| WB| 220-240V~|
50/60Hz| 1
BN398X LED40 L1200 L1 S WB| 80| 26| 3800| 3000/4000/6500| D| WB| 220-240V~|
50/60Hz| 1.7
| | | | | | | | |
| | | | | | | | |
Sensor
Accessories for option
WARNING:
Luminaires with two optic diffusers. one is transparent, another is frosted.
Please tear off the protective film after installation
- The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
- Do not switch it on before completing the installation.
- The luminaire is suitable for direct mounting or normally flammable material.
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similarly qualified person.
- The corrosive atmosphere or hazardous materials such as sulfur, chlorine, phthalate, etc must be avoided during the use and storage.
- Luminaires are only for indoor use. For under-vibration ambient luminaires’ use, please confirm with signify agents
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person in order to avoid a hazard.
- For the controller terminal, the insulation between LV supply and control conductor is basic insulation at least.
- Please insult Signify Luminaires (Shanghai) Co., Ltd. to choose products when the application environment has a vibration.
- The product is IPX0 & as such is not protected against water ingress & as such we strongly recommend that the environment in which the luminaire is to be installed suitably checked If the above advice is not taken and the luminaires are subject to water ingress, Philips / Signify cannot guarantee safe failure & product warranty will become void.
Ceiling mounting equipped with symmetrical brackets
- According to mounting sizes to drill holes and proper depths.
- Insert plastic pipes into holes
- Fix brackets by screws ST3.9×30 (2x)
Note:
Accessories BY398Z CM-S are Not included in the luminaire. Need to order
accessories.
Mounting sizes for ceiling mounting
Type | L 1 ( mm) |
---|---|
BN398X/L600 | 387±20 |
BN398X/L1200 | 843±20 |
BN398X/L1500 | 1124±20 |
PVC insulated layer
3 pole 0.75~1mm² Multi-core with PVC insulated layer
Notice:
Correct connection for polarities
Note:
Accessories BY398Z CM-S are Not included in the luminaire. Need to order
accessories.
Symmetrical surface mounting
Symmetrical suspending brackets with pipe mounting
Fixing pipe to the ceiling surface
Note:
Accessories BY398Z SPM-S and BY208Z SP are Not included in the luminaire. Need
to order accessories.
Sizes on symmetrical suspending brackets with pipe mounting
Type | L 2 ( mm) |
---|---|
BN398X/L600 | 387±20 |
BN398X/L1200 | 843±20 |
BN398X/L1500 | 1124±20 |
Multi-core
Notice:
Correct connection for polarities
Note:
Accessories BY398Z SPM-S are Not included in the luminaire. Need to order
accessories.
Symmetrical suspending brackets with pipe mounting
Height(H)
| Minor movement(R)*
| Major movement(R)*
---|---|---
3m| 2m| 3m
Movement definition reference to NEMA WD 7. All sensor-related performance range specifications are typical results @ Ta 25 °C.
If multiple luminaires are used in the same area, the distance between the different sensors should be at least 1.5 meters. This is to prevent a sensor from “seeing” the light variation of the other luminaire and trying to act on it.
Sensor far away from heat source
Sensor far away from the air outlet
WARNINGS
- Please read this manual carefully before installing or using the product.
- The sensor should be installed far away from the door or window where there is wind speed and convection, otherwise there will be frequent and accidental triggering.
- the recommended height to place the sensor in the ceiling is 3 meters to assure movement coverage and detection.
- Sensor away from signal devices such as routers (Zigbee, WIFI, etc.).
IMPORTANT
- Do not touch the sensor with hard objects.
- Do not hold the sensor by hand.
- If the sensor is deformed, contact the dealer to replace it.
Application area
- Conference rooms
- Individual offices
- Open offices
- Classrooms
- Storage and break areas
- Restrooms
- Lobbies
- Stairways
DISCONNECTING BEFORE SERVING
- Luminaire has basic insulation between Low Voltage supply and control conductors.
- The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similarly qualified person.
- Storage, installation, use, operation, and maintenance of the products need to be performed exactly according to the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to a warranty. Bolts with an indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over a lifetime.
- This product contains a light source of energy efficiency class: see table or label.
© 2021 Signify Holding
All rights reserved. Reproduction in whole or in part is prohibited without
the prior written consent of the copyright owner. The information presented in
this document does not form part of any quotation or contract, is believed to
be accurate and reliable, and may be changed without notice. No liability will
be accepted by the publisher for any consequence of its use. Publication
thereof does not convey nor imply any license under patent- or other
industrial or intellectual property rights.
Signify Holding
The Netherlands
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>