EMERSON ST4-2P Aventics Sensor with and without IO-Link Instruction Manual
- June 4, 2024
- Emerson
Table of Contents
Operating instructions
AVENTICS™ ST4-2P
Sensor with and without IO-Link
About this document
These instructions contain important information on the safe and appropriate installation and operation of the ST4-2P sensor.
Read these instructions completely before working with the ST4-2P sensor. Also, see in particular g 2. For your safety.
1.1 Related documents The ST4-2P sensor is a system component. Also, observe the system documentation from the system manufacturer.
For your safety
The ST4-2P sensor has been manufactured according to the accepted rules of
safety and current technology. There is, however, still a danger of personal
injury or damage to equipment if the following general safety instructions and
the warnings before the steps contained in these instructions are not complied
with.
1. Read these instructions completely before working with the ST4-2P sensor.
2. Keep these instructions in a location where they are accessible to all
users at all times.
3. Always include the operating instructions when you pass the ST4-2P sensor
on to third parties.
2.1 Intended use
- The ST4-2P sensor is for commercial use only.
- Only use the ST4-2P sensor in AVENTICS handling devices with C-slot.
- Use within the limits listed in the technical data.
Intended use includes having read and understood these instructions, especially chapter g 2. For your safety.
2.2 Improper use
It is considered improper use when the ST4-2P sensor
- is used for any application not stated in these instructions, or
- is used under operating conditions that deviate from those described in these instructions.
2.3 Personnel qualifications
Assembly and commissioning require basic electrical and pneumatic knowledge.
Assembly and commissioning may therefore only be carried out by qualified
electrical or pneumatic personnel or an instructed person under the direction
and supervision of qualified personnel. Qualified personnel is those who can
recognize possible dangers and institute the appropriate safety measures, due
to their professional training, knowledge, and experience, as well as their
understanding of the relevant regulations pertaining to the work to be done.
Qualified personnel must observe the rules relevant to the subject area.
2.4 Presentation of information
2.4.1 Warnings
In this documentation, there are warning notes before the steps whenever there
is a risk of personal injury or damage to equipment. The measures described to
avoid these hazards must be followed.
Structure of warnings
SIGNAL WORD
Hazard type and source Consequences of non-observance Precautions
WARNING
Possible danger to the life and health of persons. Failure to observe these
notices can result in serious health consequences, including death.
CAUTION
A possible dangerous situation. Failure to observe these notices may result in
minor injuries or damage to property.
NOTICE: Possibility of damage to property or malfunction. Failure to
observe these notices may result in damage to property or malfunctions, but
not in personal injury.
2.4.2 Symbols
Recommendation for the optimum use of our products. Observe this information
to ensure the smoothest possible operation.
2.5 The following must be observed:
2.5.1 General information
- Observe the regulations for accident prevention and environmental protection for the country where the device is used and at the workplace.
- Do not modify or convert the device.
- Only use the device within the performance range provided in the technical data.
- The ST4-2P sensor is not a safety component in terms of the Machinery Directive.
- Use a power source in compliance with IEC/DIN EN 60204-1.
2.5.2 During assembly:
- Make sure the relevant system component is without pressure or voltage before assembling the product or when connecting and disconnecting plugs.
- Protect the system against being restarted. Hang signs on the main switches that warn workers against switching the system on.
- Avoid ferritic parts in the immediate vicinity of the sensor ST4-2P.
2.5.3 During operation:
- Only commission the sensor after it has been completely assembled, as well as correctly connected and tested.
Device description
The ST4-2P sensor is a magnetic position sensor with two switching points. It is intended for end position inquiry and intermediate position detection on pneumatic cylinders. The ST4-2P sensor detects positions without any contact. Using the teach-in button, switching points can be set exactly for all piston positions. See g 5.3 Storing switching points.
Scope of delivery
- 1 set of operating instructions
- 1x sensor
- 1x hexagon screwdriver wrench size 1.3
Assembly and commissioning
WARNING
The danger of injury if assembled under pressure! Injuries and damage to the
device or system components may occur if the pressure is not switched off
before beginning assembly. Make sure that the relevant system part is without
pressure before you assemble the product.
Fig. 1: Mounting the sensor
1. Sensor | 2 . C-slot |
---|---|
3. Mounting screw | 4. Center of sensor |
Required tool: Hexagon screwdriver wrench size SW 1.3.
- Set your handling device to the center of the working stroke.
- Insert the sensor (1) from above in the center of the C-slot (2).
5.1 Mechanically adjusting the ST4-2P sensor
See g Fig. 1
Align the sensor to the center of the measurement range (observing the center
of the sensor (4)) and tighten the mounting screw (3).Tightening torque: MA =
8 +5 Ncm.
Mechanically adjusting the ST4-2P sensor for cylinders, MSC, and RCM
series
Align the center of the sensor to the center of the stroke (X) of the
actuators and firmly tighten the mounting screw. Tightening torque: MA = 8+5
Ncm. Also, observe the following during assembly:
MSC series mini slides
The mini slides must be retracted. The stroke center (X) is measured from
the front plate.
Stroke | 10mm | 20mm | 30mm | 40mm | 50mm |
---|---|---|---|---|---|
MSC variants | Stroke center (X) | Stroke center (X) | Stroke center (X) | Stroke | |
center (X) | Stroke center (X) | ||||
8 | 44 | 39 | 44 | 49 | 54 |
12 | 65 | 60 | 55 | 60 | 65 |
16 | 63 | 58 | 53 | 58 | 64 |
20 | 69 | 64 | 59 | 65 | 68 |
25 | 80 | 75 | 70 | 75 | 82 |
**Series RCM rotary compact module
** The stroke center (X) is measured from the end cover.
RCM variants | Stroke center (X) in mm |
---|---|
6 | 35.5 |
8 | 38.5 |
12 | 54 |
16 | 58 |
20 | 62 |
25 | 82.5 |
5.2 Electronically adjusting the ST4-2P sensor
-
Set your handling device to the center of the working stroke.
-
Connect the sensor to a suitable operating voltage. See g 9. Key technical data.
****The sensor must be switched on outside of any magnetic fields that could influence it. -
Press the teach-in button 8-10 s until both LEDs flash alternately.
-
Insert the sensor (1) from above in the C-slot (2), slide the sensor into the C-slot until both LEDs are on simultaneously, and tighten the mounting screw (Tightening torque: MA = 8+5 Ncm. See g Fig. 1.
5.3 Storing switching points
|
---|---
Fig. 2: Teaching in and checking the stored switching points
A Teach switching point 1
B Teach switching point 2
C Check taught-in positions
WARNING
Risk of uncontrolled actuator movements when the pneumatics are switched on!
There is a danger of personal injury if the system is in an undefined state. u
Put the system in a defined state before switching it on. Commissioning may
only be carried out by qualified electrical or pneumatic personnel or an
instructed person under the direction and supervision of qualified personnel.
See g 2.3 Personnel qualifications.
- Connect the sensor to a suitable operating voltage. See g 9. Key technicaldata.
- Teach in the working stroke (two switching points) as follows:
- Set the first piston position for the working stroke (switching point 1).
- Press and hold the teach-in button for 3 seconds (A). LED 1 will flash.
Release the teach-in button. Switching point 1 is stored. LED 2 will flash
(for switching point 2).
Set the second piston position for the working stroke (switching point 2) (B).
Press and hold the teach-in button for 1 second (B). Switching point 2 is
stored.
****If the switching point is outside the detection range of the sensor, the
teach-in process will be interrupted. In this case, the LED will flash in
short intervals.If the teach-in process is not complete, it will be
interrupted after 90 seconds (timeout). The last stored switching points will
remain active.
5.4 Checking the stored switching points
See g Fig. 2
-
Move the piston to the position of switching point 1. The switching point 1 LED lights up: switching point recognized (C). LED does not light up: switching point not recognized.
-
If the switching point is not recognized, check the operating conditions and readjust.
-
Move the piston to the position of switching point 2. The switching point 1 LED goes out and the switching point 2 LED lights up: switching point recognized (C).
If the first LED does not go out or the second LED does not light up: the switching point is not recognized. -
If the switching point is not recognized, check the operating conditions and readjust.
Care and maintenance
The ST4-2P sensor is maintenance-free.
NOTICE Damage to the surface caused by solvents and aggressive
detergents! The surfaces and seals could be damaged by solvents or aggressive
cleaning agents.
Never use solvents or aggressive detergents.
- Check the fittings and plug connections regularly.
- Comply with the maintenance intervals and specifications for the entire system.
Disposal
Dispose of the ST4-2P sensor in accordance with the currently applicable regulations in your country.
Data for configuration with IO-Link
8.1 Physical layer
SIO mode | Yes |
---|---|
Min. cycle time | 2.3 ms |
Speed | 38.4 kBaud (Com 2) |
Process data width | 2 bits (frame type 2.1) |
8.2 Process data
The sensors with IO-Link have 2-bit process data in bit 0 and bit 1.
Access | Data | Data type | Default |
---|---|---|---|
R | 1 byte | UINT8 | 0 |
RW | RW | RW | RW | RW | RW | RW | RW |
---|---|---|---|---|---|---|---|
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Q2 Bit 1 | Q1 Bit 0 |
Bit 7 … 2: reserved
Bit 1 … 0: 0 = inactive, 1 = active
8.3 Direct parameter page
Manufacturer ID | 001F hex |
---|---|
Product ID | ST4-2P 0021505 |
8.4 Service data (IO-Link)
Table 1: SPDU index
Index| Meaning Bytes| Format| Access| Example|
Range| Remark
---|---|---|---|---|---|---
0x10| Manufacturer ID| Visible string| R| AVENTICS GmbH| | Exactly 16 strings
0x12| Device ID| Visible string| R| ST4-2P| ST4-2P| Exactly 16
strings
0x15| Serial number| Visible string| R| 123dez| 1-2E32|
0x16| HW version number| Visible string| R| 1.00| |
0x17| SW version number| Visible string / 4
Byte| R| 2.33| |
0x18| Application-specific
name| Visible string/max
. 16 ByteR/W| R/W| | |
0x90| Teach parameter:
switching point 1| UINT8, 8 Byte| R| | 0 … 1023| No arguments
0x91| Teach parameter: switching point 2| UINT8, 8 Byte| R| | 0 … 1023| No
arguments
0x92| Tolerance step| UINT8, 3 Byte| R/W| | 1-5|
0x28| Process data state: output 1 and output 2| UINT8, 1 Byte| R| | 00
01
10
11| Q1, Q2 inactive
Q1 active
Q2 active
Q1, Q2 active
0xE2| Hall signals channel A and channel B| UINT8, 4 Byte| R| | 0 … 1023| High
Byte Low Byte
The subindex contains no data.
Table 2: SPDU system command
Index| Meaning| Format| Access| Example| Range|
Remark
---|---|---|---|---|---|---
0x02| Teach switching
point 1| UINT8| W| | AxA0| Teach command
SP1
| Teach switching
point 2| | | | 0xA1| Teach command
SP1
| Lock global key| | | | 0xA3| Deactivates teach button
| Unlock global key| | | | 0xA4| Activates teach
button
The subindex contains no data.
Table 3: SPDU index error codes
Index | Subindex |
---|---|
0x1000 | Communication error |
0x5200 | Buffer overflow |
0x5600 | Checksum error |
0x5800 | Illegal SPDU |
0x80xx | Device-specific error |
0x8000 | No details |
0x8023 | Access denied |
0x8030 | Parameter value out of |
Table 4: Event data
Meaning | Mode | Type | Instance | Error code |
---|---|---|---|---|
Parameter changed | Once | Info | Application | 0xFF10 |
Communication error | Once | Error | Unknown | 0xFF10 |
Key technical data
Measuring range | 0… 50 mm |
---|---|
Electrical version | DC 4 (wire) |
Supply voltage DC | 12 … 30 V |
Residual ripple | s 10 % (Based on the operating voltage) |
Voltage drop | s 2.2 V |
Power consumption (not actuated) | s 15 mA |
Continuous current | s 100 mA |
Hysteresis | 1.0 mT |
Reproducibility | s 0.1 mT (At a constant power supply and ambient temperature) |
EMC | EN 60 947-5-2 |
Switch output | PNP |
Output function | Make contact function |
Connection type. cable
Cable with plug (4-pin)| 2 m PUR, 0.3 m PUR M8, M12
Interface| with/without IO-Link (depending on the version)
Degree of protection| IP67
Wire break protection| Yes
Short circuit resistance| Yes
Reverse polarity protection| Yes
Switch-on pulse suppression| Yes
Shock vibration load| 30 g, 11 ms/10 … 55 Hz, 1 mm
Housing material| PA
Ambient temperature| -20 … +75 °C
Pin assignment
|
---|---
Table 5: Pin assignment for plugs M8x1 and M12x1
Pin | Use | Cable / wire color |
---|---|---|
1 | +UB:24 V supply | Brown |
2 | Out 1: Switch output 1 | White |
3 | GND: Reference potent | Blue |
4 | Out 2: Switch output 2 / IO-Link | Black |
Dimensions
|
---|---
Documents / Resources
|
EMERSON ST4-2P Aventics Sensor with and without IO-
Link
[pdf] Instruction Manual
ST4-2P, Aventics Sensor with and without IO-Link, Aventics Sensor, ST4-2P,
Sensor
---|---
References
- AVENTICS – Smart, reliable solutions for pneumatic automation | Emerson US
- Contact Us | Emerson US
- Contact Us | Emerson US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>