CITY THEATRICAL 5620 QolorFLEX 3x10A Dimmer User Guide
- June 4, 2024
- City Theatrical
Table of Contents
CITY THEATRICAL 5620 QolorFLEX 3x10A Dimmer
FEATURES & COMPONENT IDENTIFICATION
City Theatrical’s QolorFLEX® 3x10A Dimmer is our most versatile and feature
rich dimmer. It may be user configued as one channel of 30A, two channels of
15A each, or three channels of 10A each. The large backlit LCD display and
five button cont ol makes the QolorFLEX™ 3x10A Dimmer the industry leader in
ease of set-up and operation. It accepts wired data from any
controller/console with DMX output, can be paired with one of our wireless
transmitting/ receiving systems (SHoW Baby® 6/ SHoW DMX Neo®), and has stand
alone dimmer settings to allow use without a lighting controller/console
The QolorFLEX™ 3x10A Dimmer’s additional features include: four selectable
dimming curves/modes, variable smoothing rates, film/video modes, stating DMX
address, and it is fully RDM enabled. 9-24VDC 30A max input. 30A max output
per device.
Controls, Connections and Features
Front Panel
LCD Display: This 2 line by 16 character display shows all of the Menu titles,
command options, configuration data, and other text and graphic data. The
backlight turns on whenever a button is pushed and turns off automatically
after a preset time-out. The backlight off time-out is adjustable via the
Misc.
Control Button Pad: This five-button pad is the main control
interface for the QolorFLEX™ 3x10A Dimmer. The button functions are UP, DOWN,
LEFT/BACK, RIGHT/FORWARD, and ENTER. During normal operation (default
configuration), the Left, Down and Right Buttons serve as Bump Buttons for the
three dimmers in the unit.
Back Panel
Anderson 45A Power Pole DC Power Input Connectors (Red/Black): This is the
+VDC power input for the QolorFLEX 3x10A Dimmer, and mates directly with the
30A and 45A Anderson Power Pole connectors on the CTI # 5540 12V 12AH
Batteries, CTI Anderson Twofers, cable assemblies, and other devices. The
QolorFLEX 3x10A Dimmer is capable of drawing up to 30 amps of DC power, so be
sure that the connected input power wiring is up to the task! Be sure the
power connection is polarized correctly before connecting an alternative
supply.
Anderson 45A Power Pole DC Power Dimmer Output Connectors (Yellow/Blue): These
are the +VDC dimmed outputs for the QolorFLEX 3x10A Dimmer, and are labelled
A, B and C. They mate directly with the 30A and 45A Anderson Power Pole
connectors on CTI Anderson Twofers, cable assemblies, and other devices. The
QolorFLEX 3x10A Dimmer is capable of outputting up to 30 amps of DC power, so
be sure that the connected output power wiring is up to the task!Reset Switch:
This little recessed switch resets the Microcontroller in the QolorFLEX 3x10A
Dimmer. Use a paper clip or other small object to press if required.
5P XLR Male Connector: DMX/RDM Input. Connect your DMX512 source here using
any ESTA compliance DMX512 cable. 5P XLR Female Connector: DMX/RDM Pass-
Thru/Output. When the Transmitter is connected to a conventional DMX
controller, this connector serves as a DMX pass-thru.
DMX Termination Switch: The QolorFLEX 3x10A Dimmer DMX Input is provided with a conventional manual termination switch. Switch the handle to ON for end-of line DMX Termination.
Menu System
Addressing
- DMX Start
- DMX Personality
Level Tests
- Dimmer A Level
- Dimmer B Level
- Dimmer C Level
Curve Selection
- Dimmer Curve A
- Dimmer Curve B
- Dimmer Curve C
- LED TV/Film Mode
Misc. Settings
- Bump Buttons
- Data Loss T-Out
- Backlight T-Out
- Battery Voltage
- RDM Label RDM
- Unique ID Input
- Status Restore
- Defaults Firmware
- Version
After power-up the LCD display will read:
QolorFLEX® 3x10A Dimmer
DMX: No Data (or) OK
The Start Up display reports DMX connection status (“DMX: OK” or “DMX: No
Data”). Press the center ENTER button to access the menus.
Menus:
Addressing
- DMX Start: Set the Starting DMX address for the Dimmer
- DMX Personality: Set the DMX Personality for the Dimmer as either Triple Dimmer, Double Dimmer, or Single Dimmer
Level Tests
- Dimmer A Level: Set Dimmer A to a Level in %
- Dimmer B Level: Set Dimmer B to a Level in %
- Dimmer C Level: Set Dimmer C to a Level in %
Curve Selection
- Dimmer Curve A: Select either ISL, Linear, LED, or Non-Dim.
- Dimmer Curve B: Select either ISL, Linear, LED, or Non-Dim.
- Dimmer Curve C: Select either ISL, Linear, LED, or Non-Dim.
The ISL and Linear curves are optimized for incandescent loads, and the LED
curve is optimized for LEDs.
LED TV/Film Mode: Five options for LED (mode 3 by default).
LED Smoothing: Six different delay times to make LED dim at different rates;
5ms, 10ms, 50ms, 100ms, 200ms and 400ms (100ms smoothing by default).
Misc. Settings
- Bump Buttons: Enables or Disables Bump Buttons
- Data Loss T-Out: Adjust how long the last valid DMX level is held if DMX is lost, from 5 minutes – 120 Minutes, plus infinity
- Backlight T-Out: Allows adjustment of the Backlight automatic shutoff time-out from Always off, through 1-240 seconds on, to Always on
- Battery Voltage: Displays connected battery voltage
- RDM Label: This is an editable field that allows the user to create a unique alpha-numeric 16 character RDM label for the unit
- RDM Unique ID: This is a non-editable field that displays the RDM Unique ID Input Status: Displays input status as DMX OK or DMX No Data
- Restore Defaults: Restores factory defaults as DMX start 1, Triple Dimmer, ISL Curve on all, 10 sec. backlight time-out, 5 min. DMX data loss time-out Firmware Version: Displays firmware version