NUDO UTILITE Interlocking Wall and Ceiling Panels Instruction Manual
- June 3, 2024
- NUDO
Table of Contents
NUDO UTILITY Interlocking Wall and Ceiling Panels
INTERLOCKING WALL & CEILING PANELS
utility panels are easy to install, and the interlocking nature of the panels offers a near-seamless appearance that is easy to clean. These versatile panels can be installed quickly, both vertically or horizontally, directly to studs or substrates. the utility provides an effective option when building clean rooms at a very attractive price point.
- 100% moisture resistant
- Will not corrode
- Ideal for high water exposure areas
- Clean, smooth, bright white surface
- Meets USDA and FDA requirements
- Class A fire-rated
- Interlocking panels
- Lightweight panels
- Ease of installation
- 92% light reflectivity
Nudo is excited to announce the investment in a new extrusion line in Springfield, IL to meet the growing demands of UtiLite!
POPULAR APPLICATIONS
- Commercial Kitchens Dairy Facilities Exam Rooms
- Food Preparation Areas
- Laboratories Healthcare Facilities Service Areas Locker Rooms
- Car Wash Facilities Veterinary Clinics Pharmaceutical Plants Clean Rooms
- Restrooms
- Marine Facilities Food Processing Plants Grow Rooms
PHYSICAL CHARACTERISTICS & PROPERTIES
Standard Sizes
- 16” x 8’ 24” x 8’
- 16” x 10’24” x 10’
- 16” x 12’ 24” x 12’
- 16” x 16’ 24” x 16’
- 16” x 20’ 24” x 20’
Drop-In Ceiling Sizes
2’ x 2’ 2’ x 4’
0.350” Nominal Thickness Fire-Rating: Class A Nominal Thickness: 0.40”
Certifications
- Meets LA County Requirements for walls and ceilings Meets USDA Requirements for walls and ceilings
- Meets FDA Requirements for walls and ceilings
- CFIA – ULCS 102.2 – Class A
Warranty
utility interlocking liner panels are covered under a limited warranty for a period of two (2) years from the date of original purchase.
Physical Properties
Typical Value | Unit | Test | Method Property |
---|---|---|---|
Surface Burn Test | Class A | NFPA / IBC | ASTM E84 |
Flexural Strength | 2,233 | lbf / in 2 | ASTM C393 |
Flexural Modulus | 156,976 | psi | ASTM C393 |
Flexural Load | 10,496 | psi | ASTM D3043 |
Tensile Strength | 1,308 | psi | ASTM D638 |
Izod Impact | 1.57 | ft-lbs / in | ASTM D256 |
V-9-Division Bar
V-15-Outside Corner V-19-Edge Cap
V-21-Inside Corner
CS-125-Counter Sinking Screw
| | |
-
1500 Taylor Avenue Springfield, IL 62703www.Nudo.com
-
Form 1002.L.Rev6.2021
-
Ph: 800.826.4132
-
Fax: 217.528.8722
-
Visit www.Nudo.comor
-
contact our local dealer for details.
Documents / Resources
| NUDO
UTILITE Interlocking Wall and Ceiling
Panels
[pdf] Instruction Manual
UTILITE Interlocking Wall and Ceiling Panels, UTILITE, UTILITE Ceiling Panels,
Interlocking Wall and Ceiling Panels, Wall and Ceiling Panels, Ceiling Panels,
Wall Panels, Interlocking Panels
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>