Congratulations!
Your new Hunter thermostat will provide years of reliable service. Using this digital thermostat will provide more uniform comfort in your home through the seasons. Thank you for buying a Hunter product!
Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, call Hunter Technical Support at 1-888-830-1326 from 8am to 5pm Central Time. Remove the mylar label from the display window.
IMPORTANT INFORMATION
-
This thermostat is designed to work on the following systems • Gas – Standing Pilot
• Gas – Electronic Ignition
• Gas – Fired Boilers
• Gas – Milivolt Systems • Oil – Fired Boilers
• Oil – Fired Furnace
• Electric Furnace
• Electric Air Conditioning This thermostat will NOT control single-stage or multi-stage heat
pumps or 110/220 V baseboard electric heating systems. -
Temperature Range
This thermostat can be set between 45°F and 95°F (7°C and 35°C).
However, it will display room temperatures from 30°F to 99°F (0°C
and 37°C). “HI” will be displayed if the temperature is higher than
99°F (37°C), and “LO” will be displayed if the temperature is lower
than 30°F (0°C).
This thermostat will automatically cutoff in Heat mode if the temperature
rises above 95°F (35°C), and automatically cutoff in Cool
mode if the temperature drops below 45°F (7°C). -
Compressor Protection
This thermostat provides a 3.5 minute delay after shutting off the
cooling system before it can be restarted. This feature will prevent
damage to your compressor caused by rapid cycling. It does not
prevent a rapid compressor restart due to short power outages. -
Battery Warning
Two fresh AA alkaline batteries should provide well over one year
of service. However, when the batteries become drained, the Low
Battery Indicator will flash on the display. When this message occurs,
install new alkaline batteries. You have approximately 1 minute
to change the batteries and keep the thermostat’s settings. Once
the batteries have become too low to ensure proper operation,
your system will be turned Off, and the display will be cleared except
for flashing Low Battery Indicator on the LCD display.
CAUTION: When only the battery icon flashes on the display,
the thermostat is shut down, and your system will no longer
operate. In this condition, there is no temperature control of
your dwelling.
NOTE: If you plan to be away from the premises over 30 days, we
recommend that you replace the old batteries with new alkaline
batteries prior to leaving.
FEATURES
INSTALLATION
What You Need
This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials.
- Slotted Screwdriver(s)
- Small Philips screwdriver
- Hammer
- Electric drill and 3/16” bit
- Two 1.5 V (AA) size alkaline batteries
Remove Old Thermostat
CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully. Wires must be labeled prior to removal.
IMPORTANT! Turn off the power to the furnace at the main power panel or
at the furnace.
Remove existing thermostat cover and thermostat. See Figure 1. Some
thermostats will have screws or other locking devices that must first be
removed. Once the wall mounting plate is exposed, look for wires.
If wires are not visible, they may be connected to the back of the wallplate. Again, look for screws, tabs, etc. Some models have doors that open to expose wires and mounting screws. See Figure 1.
Typical Home Thermostats
Wire Labeling
-
Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in Table A below.
-
The number of wires in your system can be as few as two (for heat only systems), as many as eight, or any number in between. If you follow the labeling procedures correctly, you do not have to be concerned about how many wires there are.
-
There is often no terminal marking on the existing thermostat of two wire, heat only systems. Just connect either of the wires to the Rh terminal, then connect the other wire to the W terminal to complete the circuit.
-
IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE
SELF-ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN
TABLE A BELOW. (For example, attach the label marked W to the wire that goes to the W or H terminal on your existing thermostat.) IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard. -
After labeling wires, disconnect them from the existing thermostat
terminals. -
Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall.
-
If hole in wall is larger than necessary for wires, seal this hole with insulating material so that no hot or cold air can enter the back of the thermostat from the wall. This air could cause a false thermostat reading.
Table A
NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non-battery powered thermostats.
Mount Wallplate and Thermostat
- Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2.
- Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided, if your existing holes do not line up with those on the wallplate.
- Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall.
- Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. See Figure 3.
NOTE: 5-wire Systems
If your thermostat has one wire marked R or Rh (2, 3, or 4-wire system), then leave the jumper wire between the Rh and Rc terminals on the wallplate. Otherwise, if you have separate Rh and Rc wires (5-wire system), then remove the jumper wire between the Rh and Rc terminals.
Connect Wires and Mount Thermostat to Wallplate
- Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not connected to the old thermostat.
- Refer to the Wiring Diagrams below to be sure your system is wired correctly.
- Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with your system or thermostat.
- Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate.
- Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO.
- Insert the tabs on top of the thermostat body into the slots at the top of the wallplate. Press the bottom of the thermostat body into the snap on the bottom of the wallplate. Refer to Figure 2. (NOTE: Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.)
- Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment.
- Switch on the main power at the panel or furnace.
Wiring Diagrams
Selector Switches
In order for this thermostat to control your system, the system type must be specified by the selector switches on the printed circuit board inside the thermostat. There is also a selector switch for your choice of Fahrenheit or Celsius temperature display.
-
Heating System Selector (HG – HE switch) The factory position for this switch is in the “HG” position. Leave it in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat and Fan come on as expected after installation. If the Fan operation
is normal, leave it in the “HG” position. If the Fan does not come on within a minute of the thermostat calling for heat, change the switch position to “HE”. The system selector has no effect in the cooling mode.
NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay. -
F° / C° selector (Fahrenheit / Celsius)
Your thermostat is set for F° mode from the factory. In order to change to C° mode, slide the switch to C° and press the reset button on front of the thermostat with a paper clip.
NOTE: Unless the reset button is pressed, the thermostat will not change temperature mode.
OPERATION
Start-up
The LCD will show the factory default display of 70°F (21°C) when batteries are first installed, or after the Reset button is pressed. The temperature will update after a few seconds.
System Selector Switch
The System Selector switch on the front of the thermostat determines the
operating mode of the thermostat. You may select COOL, OFF, HEAT.
NOTE: Anytime you install or remove the thermostat from the wallplate,
slide the System Selector to the OFF position to prevent the possibility of a
rapid system On-Off.
Fan Switch
The Fan switch should normally be located in the AUTO position. The Fan will
be turned on along with normal operation of your system. In a normal gas or
oil furnace, the Fan will be turned on by your furnace after its warm-up
delay. For electric heat and air conditioning operation, the Fan will turn on
with the system. To run the Fan on continuously, slide the Fan switch to the
ON position.
Review Current Set Temperature
- Press either the up or down key for less than 1 second to see the Set Temperature. The factory default is 68°F (20°C) when started with the System
Switch Off or Heat, and 78° (26°C) when started with the System Switch on Cool.
Setting New Temperature
-
Press either the up or down key and hold for longer than 1 second.
-
The display will flash to show that you are in Set Temp e r a t u r e mode, then
you can release the key. -
Press either up or down again to change to your desired Set Temperature. Hold the key down for over 2 seconds to fast-advance the Set Temperature.
The display will return to the normal room temperature after the keys have been released for 3 seconds.
Filter Monitor
The thermostat counts the number of hours your system’s filter has been in use. To maximize your system’s performance and energy efficiency, change or clean your filter regularly.
When the total system run time for heat and cool reaches 400 hours, the Filter Change Indicator will flash as a reminder to check your system’s filter.
After changing or cleaning the system filter, press and hold the Filter
key for 3 seconds. The display will blink, and the counter will be reset to
zero.
Note: Pressing the Filter key at any time for less than 3 seconds will cause the Filter Change Indicator to appear on the LCD. This is only to confirm key operation, and the counter is not affected unless the key is held for greater than 3 seconds.
SPAN Setting
Your thermostat is set at the factory to cycle at 1°F (0.5°C) above and below the set temperature. (Span = 2) This setting has been designed to provide a comfortable room temperature under most all conditions. However, if you find your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time.
- Press and hold BOTH for three seconds. The display will flash, and SPAN will be displayed on the LCD.
- Press to raise the Span to 3. This setting INCREASES the cycle time by allowing your system to run LONGER.
- Press to lower the Span to 1. This setting DECREASES the cycle time by causing your system to run SHORTER.
- The Span settings remain the same for both HEAT and COOL, and can be changed in any System Switch position.
- When batteries are installed in the thermostat, or the Reset key is pressed, the Span is reset back to setting 2.
Low Battery Warning
Your thermostat has a two-stage low battery warning system. When the
batteries are first detected to be weak, the first stage low battery warning
is indicated by battery symbol flashing on the LCD display. At your earliest
convenience, you need to replace the batteries with 2 new AA alkaline
batteries.
When the batteries become too weak for normal operation, the thermostat enters the second stage low battery warning which shuts down the thermostat. In this condition, “BATT” flashes alone on the display, and the thermostat will turn your system Off. Your system will remain shut-off until the batteries are replaced.
Note: The thermostat will still keep the current Set Temperature and Filter run time in memory until new batteries are installed. After confirming that new batteries have been inserted, the thermostat will return to normal operation.
Error Mode
If the thermostat is unable to control your system due to an unexpected battery problem, the thermostat will enter Error Mode. In this condition, the thermostat flashes “Er” on the LCD display, and shuts off your system.
To correct this problem, replace the batteries with 2 new AA alkaline batteries, even if you have recently replaced them. Next, use a paper clip to press the RESET button next to the keypad. You will need to reprogram your thermostat and confirm normal operation.
If Error Mode returns, please call Technical Support at 1-888-830- 1326 for further information.
Auto Cut Off
Your thermostat will automatically cutoff in Heat mode if the room temperature rises above 95°F (35°C). It will cutoff in Cool mode if the room temperature drops below 45°F (7°C).
Note that if your system has malfunctioned and no longer responds to thermostat controls, the Auto Cut-Off will have no effect.
TROUBLESHOOTING
If you experience any other problems, call 1-888-830-1326 from 8 AM to 5 PM Central Time for technical assistance.
Ask Your Local Retailer for Other Quality Products from Hunter.
Hunter Fan Company
2500 FRISCO AVENUE
MEMPHIS, TN 38114
Form No. 41497-01 Rev 6-29-2001 © 2001, Hunter Fan Company
Read More About This User Manuals…
Hunter-Just-Right-Thermostat-Installation-and-Operating-Manual-42999B- Optimized.pdf
Hunter-Just-Right-Thermostat-Installation-and-Operating-Manual-42999B- Orginal.pdf
Questions about your Manual? Post in the comments!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>