TECH Sinum MB-04m Wired Gate Module User Guide

June 1, 2024
TECH

TECH Sinum MB-04m Wired Gate Module

Product Information

Specifications

  • Power supply: 1W
  • Max. power consumption
  • Maximum output load: 2A (AC1) / 2A (DC1)
  • Operation temperature
  • Acceptable ambient relative humidity

Product Usage Instructions

  • The MB-04m gate module is an electronic device equipped with two non-voltage relays and two two-state inputs.
  • The device’s outputs and inputs need to be configured in the Sinum Central.
  • The module is designed for DIN rail mounting and communication with the Sinum Central is conducted via wiring.

Manual Operation

The device can be operated manually by toggling the non-voltage relay outputs on or off.

Registering Device to Sinum System

  1. Activate Identification Mode in Settings > Devices > SBUS Devices > + > Identification Mode tab.
  2. Press and hold the manual operation button on the device for 3-4 seconds.
  3. The device will be highlighted on the screen upon successful identification.

Identifying Device in the Sinum System

  1. Activate Identification Mode in Settings > Devices > SBUS Devices > + > Identification Mode tab.
  2. Hold the manual operation button on the device for 3-4 seconds.
  3. The device will be highlighted on the screen for easy identification.

FAQ

  • How do I register the device to the Sinum system?
  • To register the device, follow these steps:
  • How do I identify the device in the Sinum system?
  • To identify the device, do the following:

OVERVIEW

TECH-Sinum-MB-04m-Wired-Gate-Module-FIG-1

  • Gate module MB-04m is an electronic device equipped with 2 voltage-free relays and 2 two-state inputs.
  • The outputs and inputs of the device must be configured in the Sinum Central device.
  • MB-04m is designed to be mounted on a DIN rail.
  • Communication with the Sinum central device is done by wire.

Description

  • Power supply
  • Communication
  • Current status of the voltage-free output (ON/OFF)

Manual mode

In order to switch to the manual operation mode, press the manual operation button (1). The registration button (2) is used to switch between the controlled outputs in the manual mode. Using the button (1) (pressing it once), the user forces a change of the status (ON / OFF) – if the process has been successful, it is confirmed by a light signal from the LED labelled 1-2. When the manual mode is on, it is impossible to control the contact via the website or the application. To disable the manual operation mode, press and hold the button (1) again and hold it for 1-2 seconds. Once the manual mode has been switched off, all the output status LEDs go off and resume the state set in the Sinum application.

How to register the device in the sinus system

  • The device should be connected to the Sinum central device using the SBUS connector (3), and then enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > SBUS devices > + > Add
  • device. Then briefly press the registration button (2) on the device. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room.

How to identify the device in the Sinum system

  • To identify the device in the Sinum Central, activate the Identification Mode in the Settings > Devices > SBUS Devices > + > Identification Mode tab and hold the manual operation button on the device for 3-4 seconds.
  • The device used will be highlighted on the screen.

Technical data

  • Power supply: 24V DC ±10%
  • Max. power consumption: 1W
  • Maximum output load: 2A (AC1)* / 2A (DC1)**
  • Operation temperature: 5°C ÷ 50°C
  • Acceptable ambient relative humidity: <80% REL.H

AC1 load category: single-phase, resistive or slightly inductive AC load
DC1 load category: direct current, resistive or slightly inductive load.

Notes

TECH Controllers is not responsible for any damages resulting from improper use of the system. The manufacturer reserves the right to improve devices and update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.
Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The device is not water resistant.

  • The product may not be disposed of to household waste containers.
  • The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

EU Declaration of Conformity

Tech Sterowniki II Sp. z o.o. ul. Biała Droga 34, Wieprz (34-122)
Hereby, we declare under our sole responsibility that the module MB-04m is compliant with Directive :

  • 2014/35/UE
  • 2014/30/UE
  • 2009/125/WE
  • 2017/2102/UE

For compliance assessment, harmonized standards were used:

  • PN-EN 60669-1:2018-04
  • PN-EN 60669-1:2018-04/AC:2020-04E
  • PN-EN 60669-2-5:2016-12
  • EN IEC 63000:2018 RoHS

TECH-Sinum-MB-04m-Wired-Gate-Module-FIG-7

The full text of the EU Declaration of Conformity and the user manual are available after scanning the QR code or at www.tech- controllers.com/manuals.

CONTACT

TECH-Sinum-MB-04m-Wired-Gate-Module-FIG-8

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

TECH User Manuals

Related Manuals