Honeywell RCHT8610WF T5 Plus Smart Thermostat Installation Guide
- June 1, 2024
- Honeywell
Table of Contents
- Honeywell RCHT8610WF T5 Plus Smart Thermostat
- Product Information
- Product Usage Instructions
- Included in your box
- Tools you will need
- Removing your old thermostat
- Setup with Resideo App
- How to use
- Manual Setup
- FAQs
- FCC
- Warranty
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Honeywell RCHT8610WF T5 Plus Smart Thermostat
Product Information
- Specifications:
- Model: T5+ Smart Thermostat
- Product Codes: RCHT8610WF, RCHT8612WF, RTH8800WF
- Mounting System: UWPTM Mounting System (UWP)
Product Usage Instructions
-
Tools Required for Installation:
- Phillips screwdriver
- Smartphone for wiring documentation
- Small flat-head screwdriver
- Pencil
- Level
-
Home Wi-Fi Password
- Additional Tools (if needed):
- Resideo app for configuration
- Wire stripper
- Needle-nose pliers
- Drill and drill bit (7/32 in) for installation
-
Installation Safety Precautions:
- Disconnect power before beginning installation to avoid electrical shock.
- Avoid quick cycling of the compressor to prevent equipment damage.
- If replacing a mercury-containing control, follow proper disposal guidelines.
-
Compatibility:
- For compatibility assistance or support:
- Visit honeywellhome.com/support.
- Contact Phone: 1-800-633-3991
- Social Media: Twitter – @Honeywell_Home, Facebook – Honeywell Home
-
Included in your box
Get the most from T5 Smart Thermostat
Multiple programming options that fit your lifestyle:
- Location-Based scheduling – The thermostat uses your smartphone’s location to know when you’re away, and saves you energy. Through geofence technology, it senses your return and helps make you comfortable upon arrival. You can always manually change your preset Home and Away temperature either on the thermostat or on the Resideo app.
- Smart scheduling – Use a combination of geofencing and time scheduling to fit your busy, active lifestyle.
- Time-Based scheduling – Program your thermostat for one week; each day (each day is a different schedule); Mon-Fri, Sat, Sun; or Mon-Fri, Sat-Sun. All days with four adjustable periods per day.
- No scheduling – Control your comfort manually by adjusting temperature set points only.
- Smart Alerts. Push notifications remind you of filter changes and warn you of extreme indoor temperatures.
- Smart Response. Learns your heating and cooling system to deliver the optimal temperature at the right time.
- Auto Change From Heat to Cool. Automatically determine if your home needs heating or cooling to provide maximum comfort.
Read and save these instructions.
Tools you will need
You may need
- CAUTION: ELECTRICAL HAZARD
- Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
- CAUTION: EQUIPMENT DAMAGE HAZARD
- Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.
- CAUTION: MERCURY NOTICE
- If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.
- REQUIRED: 24 VAC POWER (“C” WIRE)
- C-Wire Power Adapter available to provide power if needed.
Compatibility
- Compatible with most heating, cooling, and heat pump systems.
- Required: 24 VAC power (“C” wire). C-Wire Power Adapter (THP9045A) can be used if Y and G are used but no C wire is available.
- Does not work with electric baseboard heat (120-240V).
- Does not work with millivolt systems.
- Does not support input (S terminals) for indoor and outdoor sensors.
- Does not support relay (U terminals) for ventilation.
- Android or iOS smartphone, tablet, or device.
Removing your old thermostat
- Turn power OFF
- To protect yourself and your equipment, Turn off the power at the breaker box or switch that controls your heating/cooling system.
- Check that your system is off
- Change the temperature on your old thermostat. If you don’t hear the system turn on within 5 minutes, the power is off.
- Note: If you have a digital thermostat that has a blank display, skip this step.
- Remove your old thermostat from the wall plate
- On most thermostats, you can take off the thermostat by grasping and gently pulling. Some thermostats may have screws, buttons, or clasps.
- Do not remove any wires from your thermostat at this time!
- Make sure there are no 120/240V wires
- Do you have thick black wires with wire nuts?
- Is your thermostat 120V or higher?
- If you answered yes to either of these questions, you have a line voltage system and the thermostat will not work.
- If you are unsure visit: honeywellhome.com/support.
- Take a picture of how your wiring looks right now
- Be sure to include the letters next to the terminals where the wires are inserted. This will be a helpful reference when wiring your thermostat.
- Tip: If the colour of your wires has faded or if 2 terminals have the same wire colour, use the wire labels provided in the package to label each wire.
- Remove any jumpers
- A jumper connects one terminal to another terminal. It may look like a small staple or even a coloured wire and must be removed before continuing. Use a screwdriver to release wires from terminals.
- The thermostat does not need jumpers.
- Record if you have wires in the following terminals Do not include jumpers as a part of your count. The thermostat does not need jumpers.
- Write down the colour of the wires
- Check mark the wires that are connected to terminals.
- Next to the check mark, write down the colour of the wire.
- Do not include jumpers as a part of your count.
- S and U terminals are not supported with this thermostat.
- If there are wires in terminals that are not listed, you will need additional wiring support.
- Visit honeywellhome.com/support to find out if the thermostat will work for you.
- Do you see a wire connected to the C terminal?
- If yes, skip to step 10. If you do not see a C wire, proceed with the options below:
- Option A – Finding the C-Wire:
- There might be an extra wire pushed into the wall or wrapped around the wire bundle.
- Gently pull the wire bundle out of the wall to check for unused wires.
- If you have an unused wire, connect that wire to the C terminal on your new thermostat in step 13.
- Connect the other end of the unused wire to the C terminal on your heating/cooling system (or the zone panel if your home uses more than one thermostat to control temperature). Be sure any other wire(s) connected to the C terminal stay securely connected when you re-tighten the terminal.
- Not all heating/cooling equipment use the C label for the 24 VAC common wire. If your heating/cooling equipment does not have a C terminal, check the system manual or contact the manufacturer to find out which terminal is the 24 VAC common.
- Complete installation by following the remaining steps in this guide.
- Option B – Using the C-Wire Power Adapter:
- If you do not have an unused wire in the wall, and Y and G wires are used, the THP9045A C-Wire Power Adapter can be used.
- Disconnect the wires and remove the old wall plate
- Use a screwdriver to release wires from terminals.
- Tip: To prevent wires from falling back into the wall, wrap the wires around a pencil.
- Installing your T5 Smart Thermostat
- Bundle and insert wires through the UWP
- Pull open the UWP and insert the bundle of wires through the back of the UWP.
- Make sure at least 1/4-inch of each wire is exposed for easy insertion into the wire terminals.
- Insert the wall anchors
- It is recommended that you use the wall anchors included in the box to mount your thermostat.
- You can use the UWP to mark where you want to place the wall anchors.
- a) Level the wall plate.
- b) Mark the location of the wall anchors using a pencil.
- c) Drill the holes.
- d) Insert wall anchors.
- e) Make sure anchors are flush with wall.
- Tip: Use a 7/32 drill bit.
- Set R-switch position and insert R-wire or wires
- Set the R-switch up or down based on your wiring notes in Step 7.
- Insert wires into the inner holes of the terminals on the UWP. The tabs will stay down once the wire is inserted.
- If you have 1 R-wire (R, Rh, or Rc)
- If you have 2 R-wires (R or Rh, and Rc)
- Connect the remaining wires from Step 8
- Tip: Do not mount the UWP to the wall before connecting the wires.
- Depress the tabs to put the wires into the inner holes of their corresponding terminals on the UWP (one wire per terminal) until it is firmly in place.
- Gently tug on the wires to verify they are secure.
- Tip: If you need to release the wires again, push down the terminal tabs on the sides of the UWP.
- Mount the UWP and close the door
- Mount the UWP using the provided screws. Install all three screws for a secure fit on your wall. Close the door after you’re finished.
- Attach your thermostat
- Align the thermostat onto the UWP and firmly snap it into place.
- Turn your power ON
- Turn on the power at the breaker box or switch that controls the heating/ cooling system.
- Return to the thermostat
- Return to the thermostat. Confirm the screen shows START SETUP.
- If it does, continue to “Setup with Resideo App” below.
- If your thermostat does not show START SETUP, please contact Resideo support.
Setup with Resideo App
- Start Setup with the app
- Touch START SETUP on the thermostat.
- Select to setup with the app
- Touch Yes on the USE APP screen.
- Your thermostat is now ready to be configured using the Resideo app
- a) Download the “Resideo” app from the App store or Google play.
- b) Open the Resideo app. Your thermostat should appear under Thermostat Found. Tap SET UP NOW as shown below to continue. If your thermostat doesn’t appear, create an account (if necessary), or sign in to your Resideo account. Then select the T5 Smart Thermostat to install.
- c) The Resideo app will walk you through the rest of setup.
How to use
How to use your Resideo App
Interested in more Resideo products? Visit honeywellhome.com to learn about all available products connected by the Resideo app. The app is regularly enhanced and may change.
How to use your T5 Smart Thermostat
Manual Setup
If your Wi-Fi network is not working, you can alternatively setup your thermostat manually and connect your phone later.
- Start manual setup
- Touch START SETUP to begin.
- Select manual setup
- On the USE APP screen, touch No.
- Navigate and edit setup options
- Use or to navigate through all the setup options. To see a list of all setup options, go to pages 6-7.
- To edit an option value, touch Edit or touch text area.
- The value is now blinking. Use or to select the correct value.
- Touch Done or touch text area once the correct value is selected.
- Finish Setup
- Touch until you see Finish Setup. Touch Select or touch text area.
- Setup Wi-Fi
- At the end of setup process you will be prompted to SETUP WIFI. If your Wi-Fi is still not working, you have to manually set the time and date. Select No on the SETUP WIFI screen.
- Set time and date
- Set daylight saving time if you are in an area that follows daylight saving time. Set date, clock format and time on the next screens.
- Your thermostat is now setup
- Refer to page 5 for more information about basic operation.
Equipment Setup Options
Note: ISU options available may vary upon the thermostat model and equipment setup.
# ISU | ISU Name | ISU Options (defaults in bold) | Notes |
---|---|---|---|
120 | Schedule Type | No Schedule MO-SU = Every day the same MO-FR, SA, SU = |
5-1-1 schedule MO-FR, SA-SU = 5-2 schedule Each Day = Every day
individual| You can change the default MO-FR, and SA-SU schedules here. To
edit periods during days, temperature setpoints, or to turn Schedule On/Off,
from the home screen, go to MENU / SCHEDULE.
125| Temp Scale| Fahrenheit , Celsius|
130| Outdoor Temp| No, Internet| Select outdoor temperature data source.
This ISU automatically defaults to the Internet when registered to the Resideo
app. An outdoor temperature is required to set the following ISUs: ISU 355
Compressor Lockout, ISU 356 Aux Heat Lockout.
200| System Type| Conventional Forced Air
Heat Pump Boiler
Cool Only
| Basic selection of system your thermostat will control.
205| Equipment Type| Conventional Forced Air Heat: Standard Gas (STD GAS),
High-Efficiency Gas (EFF GAS) , Oil, Electric, Fan Coil*| This option
selects the equipment type your thermostat will control. Note: This option is
NOT displayed if ISU 200 is set to Cool Only. Fan coil setting is for a
residential application with a hot water coil in an air-handler.
| | Heat Pump:
Air To Air, Geothermal
|
| | Boiler:
Hot Water , Steam
|
218| Reversing Valve| 0/B on Cool, 0/B on Heat| This ISU is only
displayed if ISU 200 is set to Heat Pump. Select whether reversing valve O/B
should energize on cool or on heat
220| Cool Stages (#200=Conv./ 200=HP)| 0, 1 , 2|
221| Heat Stages/ Aux/E Stages (#200=Conv./ 200=HP)| Heat Stages: 0, 1 , 2
AUX/E Stages: 0 , 1
| Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stages
for heat pump systems.
230| Fan Control| Equipment, Thermostat| This ISU is only displayed if
ISU 205 is set to Electric Forced Air or Fan Coil.
300| Auto Changeover| On, Off| OFF: The user must select heating or
cooling as needed to maintain the desired indoor temperature.
ON (Automatic): On (enabled) Allows the user to select Auto Changeover as one of the system modes from the home screen. In auto mode, the thermostat can control either heating or cooling-ing to maintain the desired indoor temperature.
303| Auto Differential| 0 °F to 5 °F or 0.0 °C to 2.5 °C| The
differential is the minimum number of degrees rise or fall required during off
cycle to switch from the last active mode (heat or cool) to the opposite mode
when the thermostat is in auto-changeover. The differential is NOT deadband.
The deadband temperature between when heating (or cooling) cycles on and
cycles off to maintain setpoint is not adjustable. The T5 thermostat uses an
algorithm that fixes the deadband at 0 °F.
355| Balance Point (Compressor Lockout)| Off, 5 °F to 60 °F (in 5 °F
increments) or -15.0 °C to 15.5 °C (in 2.5 °C or 3.0 °C increments)|
Compressor Lockout requires an outdoor temperature. Set Compressor Lockout to
the temperature below which it is inefficient to run the heat pump. When the
outside temperature is below this setting, the thermostat will lock out heat
pump and run Aux Heat only. This ISU is only displayed if ISU 130 = Internet,
ISU 200 is set to Heat Pump, ISU 221 Aux/E stages = 1,.
356| Aux Heat Lock Out (Aux Heat Outdoor Lockout)| Off, 5 °F to 65 °F (in
5 °F increments) or
-15.0 °C to 18.5 °C (in 2.5 °C or 3.0 °C increments)
| Aux Heat Lockout requires an outdoor temperature. Set Aux Heat Lockout to
optimize energy bills and to not allow it to run the more expensive Aux Heat
source above certain outdoor temperature limit. This ISU is only displayed if
ISU 200 is set to Heat Pump, AND if ISU 221 Aux/E stages = 1.
365| Cool 1 CPH (Cooling cycle rate stage 1)| 1 – 6 CPH (3 CPS)| This ISU
is only displayed when Cool /Compressor Stages is set to 1 or more stages.
Cycle rate limits the maximum number of times the system can cycle in 1 hour
measured at a 50% load. For example, when set to 3 CPH, at a 50% load, the
most the system will cycle is 3 times per hour (10 minutes on, 10 minutes
off). The system cycles less often when load conditions are less than or
greater than a 50% load.
366| Cool 2 CPH (Cooling cycle rate stage 2)| 1 – 6 CPH (3 CPS)| This ISU
is only displayed when Cool /Compressor Stages is set to 2.
# ISU| ISU Name| ISU Options (defaults in bold)| Notes
---|---|---|---
370| Heat 1 CPH (Heating cycle rate stage 1)| 1 – 12 CPH| This ISU is only
displayed when Heat Stages is set to 1 stage or more stages. Cycle rate limits
the maximum number of times the system can cycle in a 1 hour period measured
at a 50% load. For example, when set to 3 CPH, at a 50% load, the most the
system will cycle is 3 times per hour (10 minutes on, 10 minutes off). The
system cycles less often when load conditions are less than or greater than a
50% load. The recommended (default) cycle rate settings are below for each
heating equipment type: Standard Efficiency Gas Forced Air = 5 CPH; High
Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air
= 9 CPH; Fan Coil = 3 CPH; Hot Water Radiant Heat = 3 CPH; Steam = 1
CPH.
371| Heat 2 CPH (Heating cycle rate stage 2)| 1 – 12 CPH| This ISU is only
displayed when Heat Stages is set to 2 stages. The recommended (default) cycle
rate settings are below for each heating equipment type: Standard Efficiency
Gas Forced Air = 5 CPH; High-Efficiency Gas Forced Air = 3 CPH; Oil Forced Air
= 5 CPH; Electric Forced Air = 9 CPH; Fan Coil = 3 CPH; Hot Water Radiant
Heat = 3 CPH; Steam = 1 CPH.
375| Aux Heat CPH (Heating cycle rate Auxiliary Heat)| 1 – 12 CPH| This ISU is
only displayed when ISU 200 = Heat Pump and ISU 221=1. It is only displayed
when Auxiliary Heat is configured. The recommended cycle rate settings are
below for each heating equipment type: Standard Efficiency Gas Forced Air =
5 CPH; High-Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH;
Electric Forced Air = 9 CPH.
425| Smart Response| On, Off| Smart Response is a comfortable setting.
Heating or cooling equipment will turn on earlier, ensuring the indoor
temperature will match the set point at the scheduled time.
429| Max Cool Temperature| from Min. Cool Temp. to 99 °F or to 37.0 °C (90
°F or 32 °C)| The user cannot set the cooling temperature above this
level.
430| Min Cool Temperature| from 50 °F or 10.0 °C to Max. Cool Temp. (50 °F
or 10 °C)| The user cannot set the cooling temperature below this level.
431| Max Heat Temperature| from Min. Heat Temp. to 90 °F or to 32.0 °C (90
°F or 32 °C)| The user cannot set the heating temperature above this
level.
432| Min Heat Temperature| from 40 °F or 4.4 °C to Max. Heat Temp. (50 °F
or 10 °C)| The user cannot set the heating temperature below this level.
702| Air Filters| 0 – 2| This ISU refers to the number of air filters in
the system.
711| Air Filter 1 Reminder| Off
10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days
3, 4, 5, 6, 9, 12, 15 Months
| Choose either calendar or equipment run time-based reminder.
712| Air Filter 2 Reminder| Off
10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days
3, 4, 5, 6, 9, 12, 15 Months
| Choose either calendar or equipment run time-based reminder.
810| Hum Pad Reminder| Off
6, 12 Calendar Months
|
921| Dehum Filter Reminder| Off
30, 60 Calendar Days
3 – 12 Calendar Months (in 1 month increments)
|
1018| Vent Filter Reminder| Off, 3, 6, 9, 12 months|
1100| UV Devices| 0 – 2| Some systems may have two UV devices, one for
the A-Coil and another for Air Treatment. A replacement reminder can be setup
for each one separately.
1105| UV Bulb 1 Reminder| Off, 6, 12, 24 months|
1106| UV Bulb 2 Reminder| Off, 6, 12, 24 months|
1401| Idle Brightness| 1-5| Adjust brightness of an inactive backlight
(idle screen) from default 1 to 5
1410| Clock Format| 12 hour, 24 hour|
1415| Daylight Saving| On, Off| Set to Off in areas that do not follow
Daylight Saving Time.
FAQs
Will the T5 Smart Thermostat still work if Wi-Fi connection is lost?
Yes, the temperature can be adjusted directly at the thermostat. However, some features, including geofencing, are managed only through the Resideo app and will not function while the connection is down. The thermostat will automatically reconnect to Wi-Fi once the network is restored.
The T5 Smart Thermostat is not finding the in home Wi-Fi network.
The thermostat operates in the 2.4GHz range. That may be why the thermostat does not see the network but the smartphone, which operates in both the 2.4 and 5.0 GHz range, sees the network. Most routers will broadcast two networks, one SSID on the 5.0 GHz radio and one SSID on the 2.4 GHz radio.
A change was made on the Resideo app but it has not shown up on the T5 Smart Thermostat.
There may be a short delay after making temperature and setting changes in the Resideo app.
Can there be multiple users for geofencing?
Yes, there can be multiple users. Geofencing will trigger based on the last person to leave and the first person to return. To properly use geofencing with multiple users: Each user needs to create an account. Each user should use their login ID and password across his or her devices, including smartphones and tablets. No two users should share the same account.
How are multiple users set up with thermostat?
Access can be given to any or all thermostat locations through the Resideo app. Start by touching the three-line menu icon in the upper left-hand corner of the home screen. Select Manage Users and touch Add User located at the bottom of the screen. Type in the email address of the person to be invited. If they have an account set up, the location will be automatically added to their account. If they don’t have an account, they will receive an email invitation prompting them to download the Resideo app and create their own account. Note: All individuals with access to a thermostat share the same user privileges. Users added will be able to change the thermostat’s settings, as well as add or delete other users.
Is there a way to extend the signal strength?
The range or distance of the Wi-Fi signal is determined by the router. Check the router’s manual for additional information.
There is an alert that says Wi-Fi Signal Lost. What does that mean?
The Wi-Fi signal to the thermostat has been lost. Wait for the thermostat to reconnect or select a new network within the Resideo app configuration menu. If the thermostat is unable to reconnect, you will need to troubleshoot the router to determine the cause.
Why is the thermostat showing up as offline (strike-through Wi-Fi icon) on top of right corner of thermostat display?
If the thermostat displays a strike-through Wi-Fi icon on its screen or shows up as offline on the Resideo app, it has lost connection to the network. Make sure the router is powered and broadcasting. The home’s Wi-Fi network may need to be reset by power cycling the router. Consult the router’s instruction manual for directions on power cycling. When the network has been restored, the thermostat will utomatically reconnect.
An activation email hasn’t been received.
- An email will be sent from connected-Home@alarmnet.com. An activation email is needed to complete the account setup.
- If an activation email is not received after five minutes, check the Spam folder of the email account.
- If you do not find it in the Spam folder, click on the Resend button and the activation email will be resent.
- If you still do not receive your activation email, please contact the Technical Support team at 1-800-633-3991 for help.
FCC
Regulatory information FCC REGULATIONS 47 CFR § 15.19 (a)(3)
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
47 CFR § 15.21 (USA only)
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
47 CFR § 15.105 (b)
- See https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx for additional FCC information for this product.
IC REGULATIONS RSS-GEN
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Apple® HomeKit™ Setup Code
- The T5+ Smart Thermostat supports Apple HomeKit.
- Open the HomeKit app, follow the instructions, and enter the code displayed on
- Thermostat when prompted.
Warranty
2-Year Limited Warranty
For Warranty information go to honeywellhome.com.
- CAUTION: ELECTRICAL HAZARD
- Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
- CAUTION: EQUIPMENT DAMAGE HAZARD
- Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.
- CAUTION: MERCURY NOTICE
- If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.
- CAUTION: ELECTRONIC WASTE NOTICE
- The product should not be disposed of with other household waste. Check for the nearest authorized collection centres or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.
Use of the Works with Apple badge means that an accessory has been designed to work specifically with the technology identified in the badge and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. AirPlay, iPad, iPad Air, iPad Pro, iPhone and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. HomePod is a trademark of Apple Inc.
CONTACT
- Resideo Inc., 1985 Douglas Drive North
- Golden Valley, MN 55422
- www.resideo.com
- 33-00474-04 SA Rev. 11-23
- © 2023 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Wi-Fi® is a registered trademark of Wi-Fi Alliance® For more information visit honeywellhome.com.
For help, contact
- WEB honeywellhome.com/support.
- PHONE 1-800-633-3991
- SOCIAL Twitter: @Honeywell_Home,
- Facebook: Honeywell Home
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>