284-L-02c-5 Gas Stones with Fusion Basket Instruction Manual
- June 1, 2024
- GAS STONES
Table of Contents
- 284-L-02c-5 Gas Stones with Fusion Basket
- IMPORTANT SAFETY INFORMATION
- SPECIFICATIONS
- DIMENSIONS
- FIREPLACE REQUIREMENTS
- MANTEL CLEARANCES
- INSTALLING THE BURNER
- GAS SUPPLY
- STONE CONFIGURATION
- OPERATING INSTRUCTIONS
- RESETTING THE SYSTEM
- MAINTENANCE
- TROUBLESHOOTING
- Warranty
- PRODUCT INSTALLATION RECORD
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
284-L-02c-5 Gas Stones with Fusion Basket
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flam-mable vapours and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualified installer, service agency or gas supplier.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
IMPORTANT SAFETY INFORMATION
- This appliance must be installed only in a solid-fuel-burning fireplace with a working flue and constructed of noncombustible material.
- A fireplace screen must in place when the appliance is operating and must provide for the flow of combustion air.
- The installation and the provision for combustion and ventilation air must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Canadian Installation Code, CAN/CGA B149.1.
- The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures over ½ psi (3.5 kPa).
- The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply system at test pressures equal to or less than ½ psi (3.5 kPa).
- The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.
- Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
- Solid fuels shall not be burned in a fireplace where a decorative appliance is installed.
- This appliance is equipped for use with natural gas or propane and cannot be converted to other fuel.
- This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.60a-2003• CSA 2.26a-2003 Decorative Appliances for Installation in Solid-Fuel Burning Fireplaces and CAN1-2.17-M91, Gas-Fired Appliances for Use At High Altitudes.
- This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State Examiners of Plumbers and Gas Fitters has issued approval number G3-1209-252 for this appliance.
- This appliance is approved for installation in New York City. The Department of Buildings has issued MEA number 25-06-E for this appliance.
Vision Gas Burner Module, Model VBM-NG-02 Vision Gas Burner Module, Model VBM- LP-02 S/N………………………….
This appliance is equipped for:| Natural Gas/Gaz Naturel|
Propane
---|---|---
Input Rating Btu/hr| 42,000| 43,500
Min. Input (Btu/hr)| 27,000| 27,000
Orifice (DMS)| 6 Port #55| #48
Manifold Press.| 4.0″/1.0kPa| 10″/2.5kPa
Min. Supply Press.| 4.0″/1.0kPa| 11″/2.7kPa
Max. Supply Press.| 7.0″/1.7kPa| 13″/3.2kPa
These burner modules are certified by OMNI-Test Laboratories to “CSA/ANSI Z21.50-2019 / CSA 2.22-2019 Vented decorative gas appliances and CSA 2.17-2017 Gas-fired appliances for use at high altitudes” when installed in the Vision Gas Fireplace (Report #00284GL002S) and “ANSI Z21.60-2017 / CSA 2.26-2017 – Decorative gas appliances for installation in solid-fuel burning fireplaces” when installed in the Gas Stones with Fusion Basket (Report #00284GL002S). This appliance is equipped only for altitudes 0-2000 feet (0-610m) in the USA and 0-4500 feet (0-1370m) in Canada without change. This appliance must be installed under local codes, if any; if none, follow the ANSI Z223.1, or CSA-B149.1.
CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquid-shaving flammable vapours away.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.
SPECIFICATIONS
Natural Gas | Propane (LP) | |
---|---|---|
Manifold Pressure: | 4.0” (1.0 kPa) | 10.0” ( 2.5 kPa) |
Maximum Supply Pressure: | 7.0” (1.7 kPa) | 13.0” (3.2 kPa) |
Minimum Supply Pressure: | 4.0” (1.0 kPa) | 11.0” (2.7 kPa) |
Orifice Size: | 6 Port #55 DMS | #48 DMS |
Canadian Efficiency P.4: | 32% | 39% |
High Fire Input: | 42,000 BTU/hr. | 43,500 BTU/hr. |
Low Fire Input: | 27,000 BTU/hr. | 27,000 BTU/hr. |
DIMENSIONS
MODEL | A | B | C | D |
---|---|---|---|---|
GAS STONES 24” | 24” [610] | 12” [305] | 17” [432] | 6 11/16” [170] |
GAS STONES 30” | 30” [762] | 12” [305] | 17” [432] | 6 11/16” [170] |
- The premise gas supply should terminate within the shaded area, as shown on the plan view, above.
BEFORE YOU BEGIN
Before starting the installation of your Gas Stones with Fusion Basket be sure to have the following tools and supplies:
- Adjustable wrench
- Phillips and straight-blade screwdrivers
- Tape measure and frame square
- Safety glasses and gloves
- Manometer
- Leak detection fluid (non-corrosive) or gas detector
NOTE!
Reset the Gas Stones with Fusion Basket before the first fire.
See Resetting the System under OPERATING INSTRUCTIONS for details.
FIREPLACE REQUIREMENTS
- Your Gas Stones with Fusion Basket must sit fully inside your fireplace so that it properly drafts up the chimney flue.
- Be certain that the burner of your Gas Stones with Fusion Basket is behind the fireplace lintel. See Figure 1.
Note: If the fireplace has doors, they must be opened fully during the operation of the appliance.
A minimum free opening of 50 square inches must be provided by the chimney or
damper to vent the flue gases. The chimney damper must be fixed with the clamp
provided to maintain the minimum free opening. See Figure 2.
Note: The Commonwealth of Massachusetts requires that the damper be
removed or welded in the fully open position.
MANTEL CLEARANCES
- Combustible mantels may be no closer to the fireplace opening than the distances shown in the Figure 2a side view, above.
INSTALLING THE BURNER
- Place 4 AA batteries in the battery case and connect the battery case to the receiver as shown in Figure 3a.
- Ensure that the wiring is connected as shown in Figure 3b.
GAS SUPPLY
Place the burner module in the centre of the fireplace and connect the gas supply to the flexible gas supply connector provided with the burner. The gas supply line must terminate with a male ½” NPT pipe thread in the rear of the fireplace. The gas supply piping should have a separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve. The Gas Stones with Fusion Basket and its main control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures over ½ psi (3.5 kPa). The Gas Stones with Fusion Basket must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or less than ½ psi (3.5 kPa).
Warning: This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
After the gas supply has been connected, open the main supply and apply a soapy water solution to all the fittings to check for gas leaks. Never use a flame to test for leaks. If you are installing a propane burner, check that the air shutter (see Figure 5) is in the open position. Replace the burner in the burner module. Ensure that the burner inlet tube is in the shutter box.
- Place the Fusion Basket over the burner so the burner is centred in the opening in the Fusion Basket as in Figure 6.
STONE CONFIGURATION
The Gas Stones with Fusion Basket can be operated with, or without, the
decorative stones and/or embers. The following is the recommended
configuration. Slight differences in the placements are acceptable.
When using the stones and embers, begin by placing one layer of the embers
evenly over the entire burner top as shown in Figure 7.
Note: Do not overcrowd the pilot.
- Sort your stones, by size, into sixteen small, three medium and four large. Place a row of six small stones along the rear edge of the burner as shown in Figure 8.
- Next, place two large stones and three small stones on the burner as shown in Figure 9. Then place two medium and four small stones along the front edge of the burner as shown in Figure 10.
- Finally, place the remaining two large, one medium and three small stones on top as shown in Figure 11.
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING!
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
-
A. This appliance is equipped with an ignition device that automatically lights the pilot. Do not try to light the pilot by hand.
-
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
- If you cannot reach your gas supplier, call the fire department.
-
C. Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
The Gas Stones with Fusion Basket has two safety features which affect the operation:
- two-button child safety ignition
- 45-second safety timer
The safety ignition requires that two buttons be depressed to begin the ignition sequence and the timer requires that 45 seconds elapse between start attempts.
LIGHTING THE FIRE
- STOP! Read the safety information above.
- This appliance is equipped with an ignition device that automatically lights the pilot. Do not try to light the pilot by hand.
- Push the OFF button on the remote control to insure the appliance is off.
- Wait five (5) minutes to clear out any gas. Then smell for gas including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
- Press the OFF and LARGE FLAME ( ) buttons simultaneously. Release the buttons once you hear a beeping noise. This acoustic signal tells you that the start sequence has begun. Further short signals will continue until the main gas flows and the burner is lit. If the pilot or burner does not light, go back to Step 3, above.
- Use the LARGE FLAME ( ) and SMALL FLAME ( ) buttons to adjust the flame height.
TO TURN OFF THE HEATER
- Push the OFF button on the remote control to turn the appliance off.
- After powering off the fireplace, it can take about 45 seconds before you can light it again.
RESETTING THE SYSTEM
This procedure resets the system as well as ‘pairs’ the remote and the receiver. It is only needed to be performed once but can be done as often as necessary. To reset the system:
- Press and hold the receiver reset button until you hear the second of two beeps then
- release the reset button and, within twenty seconds,
- Press the SMALL FLAME button on the remote until you hear two confirming beeps
The receiver and remote are now each reset and ready for normal operation.
Note: The system shuts off the appliance completely if there is no change in the flame height for 5 days.
Igniting the Appliance.
Ensure the ON/OFF switch is in the ON position.
On the remote control, simultaneously press and hold the OFF and buttons.
An acoustic signal indicates that the start sequence has begun.
The electronic system then checks that the main gas is flowing and ignites the
main burner; this may take up to 20 seconds.
NOTE: During start-up, the MANUAL knob on the gas valve cannot be in the
MAN position.
Manual Flame Height Adjustment.
You are now able to use the remote control. To increase the flame, the LARGE
FLAME ( )button should be depressed. Pressing the SMALL FLAME ( ) button on
the handset will reduce the flame. The main flame may be lowered down until it
is off, leaving only the pilot ignited.
Fully Extinguishing the Appliance
From any heat setting, press the OFF button for a few seconds. This will cause
the burner to fully extinguish.
The system has a safety interlock which will not allow the ignition until the
interlock rests. This may take a few minutes.
The appliance should be shut off completely using the OFF button on the
handset and not left on pilot only, except for temporary use. This resets the
system and all safety features.
Automatic Turndown.
- The valve will turn to pilot flame if there is no change in flame height for six hours.
Automatic Shut Off.
- With low battery power in the receiver, the system shuts off the fire completely. This does not happen if the power supply is interrupted.
- The system shuts off the fire completely if there is no change in flame height for 5 days.
- The system shuts off the fire if the main burner does not completely ignite approximately 20 seconds after ignition or after pushing the LARGE FLAME ( ) button.
MAINTENANCE
A qualified service agency should conduct an annual inspection and maintenance of your Gas Stones with Fusion Basket, the fireplace, the chimney, and the installation to keep it running safely. The following procedures should be performed only by a qualified service person. The gas supply should be turned off whenever a maintenance procedure is performed. All parts of the fireplace that are removed for servicing must be replaced before operation.
Cleaning the Stones and Burner.
With all parts of the fireplace at room temperature, carefully remove and
clean the stones with a soft-bristled brush. Never use a vacuum cleaner to
clean the stones. Clean the burner surface with a brush. Replace the
components according to the instructions starting on page 11 of this manual.
Inspecting the Chimney
An inspection of the chimney should be made as part of the annual service
appointment. The chimney must have no blockage and be in good repair.
Replacing the Batteries
With all parts of the fireplace at room temperature, remove the stones and
embers. Remove the Fusion Basket from the fireplace. Find the battery
compartment door on top of the receiver and slide it open. Remove the four
batteries and, minding the correct polarity, replace them with fresh AA
batteries. Close the battery compartment cover and re-set the Fusion Basket,
embers and stones according to the previous instructions.
![284-L-02c-5 Gas Stones with Fusion Basket Instruction Manual
Featured Image:
No file chosen
Update Post
Add MediaVisualText
Heading 4
H4
Close dialog
Add media
Actions
Upload filesMedia Library
Filter mediaFilter by type
Uploaded to this post
Filter by date
All dates
Search
Media list
Showing 31 of 31 media items
UPLOADING
24 / 31 – 284-L-02c-5-Gas-Stones-with-Fusion-Basket-FIG-23.PNG
ATTACHMENT DETAILS
284-L-02c-5-Gas-Stones-with-Fusion-Basket-FIG-22.png
May 23, 2024
74 KB
899 by 498 pixels
Edit Image
Delete permanently
Alt Text
Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title
284-L-02c-5-Gas-Stones-with-Fusion-Basket-FIG-22
Caption
Description
File URL:
https://manuals.plus/wp-content/uploads/2024/05/284-L-02c-5-Gas-Stones-with- Fusion-Basket-FIG-22.png
Copy URL to clipboard
ATTACHMENT DISPLAY SETTINGS
Alignment
Center
Link To
None
Size
Full Size – 899 × 498
Selected media actions
1 item selected
Clear Insert into post
No file c284-L-02c-5-Gas-Stones-with-Fusion-Basket-FIG- 22hosen](https://manuals.plus/wp-content/uploads/2024/05/284-L-02c-5-Gas- Stones-with-Fusion-Basket-FIG-22.png)
TROUBLESHOOTING
The flames should look like those in the picture above.
For replacement parts and customer service:
Contact your local Dealer
Warranty
European Home Warranty Vision and Gas Stones Family of Products
European Home warrants the Vision, Vision Vent Free, Gas Stones and Gas Stones Vent Free burners against defects in materials and workmanship for a period of TWO (2) YEARS from the date of original retail purchase. We warrant the Vision cabinet, Vision Vent Free cabinet, Fusion Basket and Beach Stones against defects in materials and workmanship for a period of FIVE (5) YEARS from the date of original retail purchase. If a defect exists, European Home will, at its option, either (1) repair the product at no charge, using new or refurbished replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product. A replacement product/part assumes the remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever provides longer coverage for you. When a product or part is exchanged, any replacement item becomes your property and the replaced item becomes the property of European Home. Nothing in the above shall be deemed to imply that this warranty shall apply to work which has been abused or neglected or shows evidence of changes or modifications by others with or without permit, damages caused by the acts of God, building settlement or moving, fire or vandalism. In addition, installation of this product that varies from the requirements stated in the instruction manual will void the warranty.
PRODUCT INSTALLATION RECORD
Installer: Please complete this form. Customer: Please retain this information.
Purchased From|
---|---
Date of Purchase|
Installed By|
Date of Installation|
Fireplace Serial Number|
Fuel Type|
CONTACT
EUROPEAN HOME
- a division of Europa Ja, Inc.
- 30 Log Bridge Road
- Building 300 – Suite 303
- Middleton, MA 01949
- www.europeanhome.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>