CPAP DC-24A19 Mini DC Adapter User Manual
- June 1, 2024
- CPAP
Table of Contents
User Manual
DC Adapter
Model No.: DC-24A19
SKU No.: LTPDC
Symbols
|
Class II Equipment
---|---
| Direct current
| Consult instructions for use
****| Marking of electrical and electronic equipment
Intended Use
The DC Adapter is intended to provide power for the Auto CPAP System (model:
Luna TravelPAP). It is intended for use in vehicles only.
CAUTION:
- Any serious incidents that occur in relation to this device should be reported to the manufacturer and the competent authority in your country.
- Read and understand the entire user manual before operating this system. If you have any questions, please contact your equipment supplier.
- The pictures in the user manual are only for reference, if they are different from the material object, the latter shall prevail.
Specifications
Product Use, Transport and Storage
Operation | Transport and Storage |
---|---|
Temperature: 5°C to 35°C (41°F to 95°F) | -25°C to 70°C (-13°F to 158°F) |
Humidity: ≤ 93% Non-condensing | ≤ 93% Non-condensing |
Atmospheric Pressure: 760 to 1060 hPa | 760 to 1060 hPa |
DC input
12Vdc-24Vdc, 3A-2A
DC Output
19Vdc, 1.26A
Type of Protection Against Electric Shock
Class II Equipment
Degree of Protection Against Ingress of Water
IP22
Model
Model No.:DC-24019
Connecting to Power
- Insert the plug of the power adapter into the DC Inlet of the device;
- plug the other end of the power adapter into the cigarette lighter socket.
CAUTION:
- Inspect the cord of power adapter often for any signs of damage. Replace a damaged power adapter immediately.
- After interruption and restoration of the power supply, the device will restore its pre-interruption working status automatically.
Disposal
When the DC adapter reaches the end of its service life, dispose of the device and packaging in accordance with local laws and regulations.
EMC Requirements
The energy emitted by this equipment passed both Radiated and Conducted Emissions Class B limits.
Test ltem | Normative References |
---|---|
Conducted Emission | EN 55011:2016/A11:2020 |
Radiated Emission | EN 55011:2016/A11:2020 |
Electrostatic Discherge Immunity Test(ESD) | IEC 61000-4-2:2008 |
Radio Frequency electromagnetic field immunity test (RS) | IEC 61000-4-3:2020 |
Power Frequency Magnetic Field lmmunity Test | IEC 61000-4-8:2009 |
Transients and Surges in the Vehicular | ISO 7637-2:2011 |
Radio disturbance characteristics in Vehicles | CISPR25 |
Guidance and manufacturer’s declaration – electromagnetic immunity
The device is intended for use in the electromagnetic environment specified
below. The customer or the user of the device should assure that it is used in
such an environment.
Immunity Test| IEC 60601 Test Level| Compliance Level
Electrostatic discharge
(ESD)
IEC 61000-4-2| ±8 kV contact discharge
±2/±4/±8/±15 kV air discharge| ±8 kV contact
±2/±4/±8/±15 kV air discharge
Radiated RF
IEC 61000-4-3| 10 V/m
80 MHz to 2.7 GHz| 10 V/m
80 MHz to 2.7 GHz
Power frequency
(50 Hz / 60 Hz)
magnetic field
IEC 61000-4-8| 50/60 Hz, 30 A/m| 50/60 Hz, 30 A/m
Note 1: At 80 MHz and 800 MHz, the higher frequency range applied.
Note 2: These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures, objects
and people.
Recommended separation distances between RF wireless communications equipment
The device is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the
device can help prevent electromagnetic interference by maintaining a minimum
distance between RF wireless communications equipment and the device as
recommended below, according to the maximum output power of the communications
equipment.
Frequency MHz| Maximum Power (W)| Distance (m)| IMMUNITY
Test Level| Compliance Level
---|---|---|---|---
385| 1.8| 0.3| 27| 27
450| 2| 0.3| 28| 28
710| 0.2| 01| 9| 9
745
780
810| 2| 0.3| 28| 28
870
930
1720| 2| 0.3| 28| 28
1845
1970
2450| 2| 0.3| 28| 28
5240| 0.2| 0.3| 9| 9
5500
5785
Note: If the immunity test level is required, the distance between the transmitting antenna and the ME device or the ME system can be reduced to 1 meter. A test distance of 1 meter was allowed by IEC 61000-4-3.
Limited Warranty
REACT HEALTH warrants that the device shall be free from defects of
workmanship and materials and will perform in accordance with the product
specifications for a period of three (3) months from the date of sale by REACT
HEALTH to the distributor. If the product fails to perform in accordance with
the product specifications, REACT HEALTH will repair or replace, at its
option, the defective material or part. REACT HEALTH will pay customary
freight charges from REACT HEALTH to the distributor location only. This
warranty does not cover damage caused by accident, misuse, abuse, alteration
and other defects not related to material or workmanship.
REACT HEALTH DISCLAIMS ALL LIABILITY FOR ECONOMIC LOSS, LOSS OF PROFITS,
OVERHEAD OR CONSEQUENTIAL DAMAGES WHICH MAY BE CLAIMED TO ARISE FROM ANY SALE
OR USE OF THIS PRODUCT. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION
MAY NOT APPLY TO YOU.
To exercise the rights under this warranty, contact the local authorized
distributors or:
REACT HEALTH
5101 Fruitville Rd., Suite 200
Sarasota, FL 34232
T: 863-226-6285
For additional information, please visit our website at:
www.reacthealth.com
icodeconnect.com is the web-based cloud solution
for report generation and storage.
Manufacturer:
BMC Medical Co., Ltd.
Room 10, 17F, Building 4, Huiya Plaza, No.16 Lize Road, Fengtai District,
100073
Beijing, PEOPLE’S REPUBLIC OF CHINA
Tel: +86-10-51663880
Fax: +86-10-51663880 Ext. 810
URL: en.bmc-medical.com
E-mail: intl@bmc-medical.com
3003020000048
Issue date: November 2, 2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>