Shelly 591349 Wi-Fi Smart Power Meter User Guide

June 1, 2024
Shelly

Shelly 591349 Wi-Fi Smart Power Meter

Product Information

Specifications

  • Model: Shelly Plus PM Mini
  • Input Voltage: 110 – 240 VAC
  • Function: Smart power meter for remote monitoring of electric appliances
  • Installation: Retrofittable into standard electrical wall boxes, behind power sockets, light switches, or other limited space areas
  • Safety: Requires installation by a qualified electrician

Product Usage Instructions

Installation

  1. Ensure all power is turned off before starting the installation process.
  2. Hire a qualified electrician to mount the device to the power grid with caution.
  3. Do not attempt to open the device as it does not contain user-serviceable parts.

Usage

  1. Once installed, connect the Shelly Plus PM Mini to your Wi-Finetwork following the provided instructions.
  2. Use the accompanying app or web interface to monitor the power consumption of your electric appliances remotely.

Maintenance

  1. Do not use the device if it shows any signs of damage.
  2. In case of issues, contact customer support for assistance; do not attempt to service or repair the device yourself.

FAQ

  • Q: Can I install the Shelly Plus PM Mini in wet locations?
    A: No, it is not recommended to install the device where it can get wet to avoid any safety hazards.

  • Q: What should I do if I notice a change in my electric appliance’s power consumption?
    A: Monitor the changes and ensure the device is correctly installed. If in doubt, consult a qualified electrician for further assistance.

USER AND SAFETY GUIDE

Wi-Fi smart power meter Shelly Plus PM Mini Read before use
This document contains important technical and safety information about the device, its safe use and installation.

CAUTION! Before beginning the installation, please read carefully and entirely this guide and any other documents accompanying the device. Failure to follow the installation procedures could lead to malfunction, danger to your health and life, violation of law or refusal of legal and/or commercial guarantee (if any). Shelly Europe Ltd.is not responsible for any loss or damage in case of incorrect installation or improper operation of this device due to failure of following the user and safety instructions in this guide.

Product Introduction

  • Shelly® is a line of innovative microprocessor-managed devices, which allow remote control of electric circuits through a mobile phone, tablet, PC, or home automation system.
  • Shelly® devices can work standalone in a local Wi-Fi network or they can also be operated through cloud home automation services. Shelly Cloud is a service that can be accessed using either an Android or iOS mobile application or with any internet browser at https://control.shelly.cloud/. Shelly® devices can be accessed, controlled, and monitored remotely from any place where the user has internet connectivity, as long as the devices are connected to a Wi-Fi router and the Internet. Shelly® devices have an Embedded Web Interface accessible at http://192.168.33.1 when connected directly to the device access point, or at the device IP address on the local Wi-Fi network. The embedded Web Interface can be used to monitor and control the device, as well as adjust itssettings.
  • Shelly® devices can communicate directly with other Wi-Fi devices through HTTP protocol. An API is provided by Shelly

Europe Ltd. For more information, please visit:
https://shelly-api-docs.shelly.cloud/#shelly-family-overview.
Shelly® devices are delivered with factory-installed firmware. If firmware updates are necessary to keep the devices in conformity, including security updates, Shelly Europe Ltd. will provide the updates free of charge through the device Embedded Web Interface or the Shelly mobile application, where the information about the current firmware version is available. The choice to install or not the device firmware updates is the user’s sole responsibility. Shelly Europe Ltd. shall not be liable for any lack of conformity of the device caused by failure of the user to install the provided updates in a timely manner.

Schematic

Legend

Device terminals:

  • O: Output terminals (bridged internally)
  • L: Live (110-240V) terminals
  • N: Neutral terminals

Wires:

  • N: Neutral wire
  • L: Live wire (110 – 240 VAC)

Installation Instructions

  • Shelly Plus PM Mini (the Device) is a small form factor smart power meter, that allows remote monitoring of electric appliances’ power consumption.
  • It can be retrofitted into standard electrical wall boxes, behind power sockets and light switches or other places with limited space.
  • CAUTION! Danger of electrocution. Mounting/installation of the Device to the power grid has to be performed with caution, by a qualified electrician.
  • CAUTION! Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
  • CAUTION! Do not open the device. It does not contain any parts that can be maintained by the user. For safety and licensing reasons, unauthorized change and/or modification of the device is not permitted.
  • CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
  • CAUTION! No SELV/PELV circuits may be connected to the terminals of the inputs and outputs, including the extension inputs.
  • CAUTION! Do not connect the Device to appliances exceeding the given max load!
  • CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
  • CAUTION! Do not use the device if it shows signs of damage!
  • Do not attempt to service or repair the Device yourself!
  • CAUTION! Do not install the Device where it can get wet.
  • CAUTION! The load current circuit has to be secured by a cable protection switch in accordance with EN60898-1 (tripping characteristic B or C, max. 16 A rated current, min. 6 kA interrupting rating, energy limiting class 3).
  • RECOMMENDATION: Connect the Device using solid single-core cables or stranded cables with ferrules. The cables should have insulation with increased heat resistance, not less than PVC T105°C (221°F).
  • Before starting the mounting/installation of the Device, check that the breakers are turned off and there is no voltage on their terminals. This can be done with a phase tester or multimeter. When you are sure that there is no voltage, you can proceed to connect the cables.
  • Connect the load to any of the O terminals of the Device and the Neutral wire, as shown on Fig. 1. Connect the Live wire to an L terminal of the Device.
  • Connect the Neutral wire to an N terminal of the Device.

Initial Inclusion

  • If you choose to use the Device with the Shelly Smart Control mobile application and cloud service, instructions on how to connect the Device to the Cloud and control it through the Shelly Smart Control app can be found in the mobile application guide.
  • The Shelly mobile application and Shelly Cloud service are not conditions for the Device to function properly. This Device can be used standalone or with various other home automation platforms and protocols.
  • CAUTION! Do not allow children to play with the buttons/ switches connected to the Device. Keep the devices for remote control of Shelly (mobile phones, tablets, PCs) away from children.

Specification

  • Dimensions (HxWxD): 29x34x16 mm / 1.34×1.11×0.63 in
  • Ambient temperature: -20 °C to 40 °C / -5 °F to 105 °F
  • Humidity 30 % to 70 % RH
  • Max. altitude 2000 m / 6562 ft
  • Power supply: 110 – 240 VAC, 50/60Hz
  • Electrical consumption: < 1.2 W
  • Max. measurement current AC: 16 A
  • Max. measurement power: 3840 W
  • RF band: 2400 – 2495 MHz
  • Max. RF power: < 20 dBm
  • Wi-Fi protocol: 802.11 b/g/n
  • Wi-Fi operational range (depending on local conditions):
    • up to 50 m / 160 ft outdoors
    • up to 30 m / 100 ft indoors
  • Bluetooth protocol: 4.2
  • Bluetooth operational range (depending on local conditions):
    • up to 30 m / 100 ft outdoors
    • up to 10 m / 33 ft indoors
  • CPU: ESP32
  • Flash: 4 MB
  • Webhooks (URL actions): 20 with 5 URLs per hook
  • Scripting: mJS
  • MQTT: Yes

Declaration of conformity

Hereby, Shelly Europe Ltd. (former Allterco Robotics EOOD) declares that the radio equipment type Shelly Plus PM Mini is in compliance with Directive 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: https://shelly.link/pluspmmini_DoC
Manufacturer: Shelly Europe Ltd.
Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail: [email protected]
Official website: https://www.shelly.com
Changes in the contact information data are published by the Manufacturer on the official website.
All rights to the trademark Shelly® and other intellectual rights associated with this Device belong to Shelly Europe Ltd.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Shelly User Manuals

Related Manuals