Migali C-SPS-1-18-NG LP Gas Heavy Duty Stock Pot Stove Instruction Manual
- June 1, 2024
- Migali
Table of Contents
- 1. Safety Protection
- 2. Brief Instruction
- 3. Manufacture’s Authority and Responsibility
- 4. Parameter Specifications
- 5. Transport and Storage
- 6. Installation and Debugging
- 7. Safety Notices and Precautions
- 8. Operating Instructions
- 9. Cleaning and Maintenance
- 10. Troubleshooting
- 11. Spare Parts
- 12. Accessories List
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Migali C-SPS-1-18-NG LP Gas Heavy Duty Stock Pot Stove Instruction Manual
Before you begin, please read these instructions carefully to use this product
correctly, to make the product perform ideally, and to avoid hazards.
Models: C-SPS-1-18-NG(LP)/ C-SPS-2-18-NG(LP) C-SPS-1-18L-NG(LP)/ C-SPS-2
-18L-NG(LP)
Dear customers and users Thank you for purchasing our products. In order to be
able to better use this product, please read these instructions carefully
before any operation, and follow the guide, to avoid any unnecessary trouble
during using.
Please keep this instruction manual in a safe place for convenient reference
and operation.
This instruction manual is subject to any change without further notice, and
the manufacturer reserves the right of final interpretation.
The appliance is designed for commercial purposes, not for household use.
A statement instructing the purchaser to post in a prominent location
instructions to be followed in the event the user smells gas. This information
shall be obtained by consulting the local gas supplier.
Gas Heavy Duty Stock Pot Stove The Installation, Operation and Maintenance Guide Contents 1. Safety Protection
1. Safety Protection
⚠ Please make sure that the operator is an authorized and licensed
technician before you allow him/her to install and operate the products. Be
sure to strictly follow this instruction guide during installation and using.
The manufacturer is not responsible for any dangers or accidents caused by
improper operation or maintenance.
⚠ Do not store flammable or explosive objects around the product. Keep all
flammable and explosive objects at a safe distance away from the product for
normal use.
⚠ Place the product in a reasonable position. Regarding related matters of
gas, customer should execute the requirements of local gas supply sector;
⚠ If you smell a gas leak, turn off the gas valves immediately and call the
gas company;
⚠ The product should not be operated by those under 18 years of age, or
those with physical or mental disorders, or disabilities that lack the
necessary knowledge or experience unless with appropriate instructions and
sufficient safety.
2. Brief Instruction
The product is a series of gas char broilers in our company production, which is novel designed, reasonable structured, convenient operated, durable used, and convenient maintained. It’s equipped with a cast-iron burner and a high efficiency stainless steel tubular burner and a pilot light, and convenient to ignite the main fire burner. This is hotel, supermarket, western restaurant, noshery and food industry’s ideal cooking product equipment.
3. Manufacture’s Authority and Responsibility
Banning of all or partial transformation to the products without the
manufacturer’s explicit authorization.
Manufacturers refused to undertake responsibility to third parties as the
following reasons:
⚠ Not follow this instruction guidance and warning in in using and testing;
⚠ Not in accordance with the requirements of technical parameters using this
product;
⚠ Incorrectly or irrationally using the product by untrained personnel;
⚠ Not obey the local law using this product;
⚠ Be repaired or changed by unauthorized technicians;
⚠ Use the spare parts or accessories provided by non-manufacturers;
⚠ Accidents caused by force majeure;
⚠ Not strictly comply with related guide of this instruction by any reason.
4. Parameter Specifications
4.1 Outline Dimensions(in)* C-SPS-1-18-NG(LP)
4.2 Information of Gas Supply and Burner
The minimum supplied gas pressure regulator is factory set at 4″Natural Gas W.C, and 10″L.P. Gas W.C. The external thread of product’s intake-tube is 3/4 inches.
5. Transport and Storage
In the process of transportation, handle carefully and keep upright to prevent damage of the product packing. Wrapped equipment should not be in open air for a long time, and shall be placed in a well-ventilated and non-corrosive gases warehouse. When equipment needs temporary storage, rainproof measures should be taken.
6. Installation and Debugging
⚠ Any erroneous installation, adjustment, refit, overhaul or maintenance
may cause property damage or personal injury. The work shall be performed by
authorized and licensed technicians, otherwise the manufacturer has the right
not to provide warranty service;
⚠ Only be installed in accordance with the local code. If no similar
standard, you should conform to the National Fuel Gas Code, ANSI Z223.1/NFPA
54, the National Gas Installation Code, CSA-B149.1, or the L.P. Gas
Installation Code, CSA-B149.2 as applicable;
⚠ The appliance individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test
pressures in excess of 1/2psi (3.45kPa).
6.1 Unpacking and Installation
⚠ Please dispose of all packaging materials and residues after unpacking;
⚠ Check the equipment. If it is damaged, please keep wrappers and
receipts which must be signed by the carrier representative (Driver), and
contact the carriers to pursue a claim within 15 days after receiving;
⚠ Check all accessories complete. Refer to P16 table 4;
⚠ Be sure to install supporting legs before using, and do not tear up any
label or logo before normal using;
⚠ Please read these instructions carefully before installation and
operation. Please contact your local agent if you have any questions;
⚠ The charbroiled shall be installed on a level, solid, non-skid and
incombustible surface, and placed in a well-lighted work area with waterproof,
and away from children and customers;
⚠ The installation position is a well-ventilated place in accordance with
the local regulations; The charbroiled must be installed under the matched
cooking fume exhauster according to the local regulations;
Important: Installation and ventilation laws, and codes are very different,
you should state and comply with all codes of the National Fire Protection
Association Inc when it comes to requirements for installation of equipment;
⚠ Screw 4 adjustable stainless steel legs in the tapping hole with four
corners of the charbroiled bottom, ensure sufficient space for ventilation;
⚠ Adjustable stainless steel legs to make the equipment level, and get
the same level with other series of the same stove; Please lift the equipment
rather than drag if you need to move it;
⚠ Supplied gas pressure regulator is factory set at 4″Natural Gas W.C,
and 10″L.P. Gas W.C;
⚠ The equipment can only be placed on the incombustible counter top, and
keep a distance of at least 6 inches(152mm) to equipment’s both sides and
back, and keep a distance of at least 4 inches(102mm) to the bottom;
⚠ Do not put anything around the equipment, and on the counter top and
bottom, in order to avoid influencing combustion and air circulation;
⚠ Leave enough distance in front of the equipment to take apart the
control panel. All major parts, in addition to the burner remove from the
front intake-tube;
⚠ It may be necessary to adjust the balance of air input by authorized
and licensed technicians;
⚠ Thread glue must be resistant to the action of liquefied petroleum
gases.
Warning! Use soap water or testing instrument to test whether piping joint
leaks or not before using, and forbid using an open flame to test!
⚠ After installing completely, you should check gas supply pressure. Use
a pressure gauge which is equipped with liquid (such as U-type pressure gauge,
the minimum value is 0.1mbar) or a digital pressure gauge to test. Steps are
as following:
- Remove top panel, and needle type pressure joint screw arbor (Fig.1), then slip rubber tube of pressure gauge over needle type pressure joint;
- Start the equipment in accordance with the instructions, measuring gas supply pressure (dynamic pressure) in the work state; Fig.1
- Access to the equipment if measured data within the limits of Table 1, otherwise, you will need to adjust gas pressure regulating valve or contact gas supplier to bargain;
- Unplug pressure gauge after you accomplish pressure testing, then install needle type pressure joint screw arbor. Important: must screw joint screw arbor, to prevent gas escape!
6.2 Debugging
It’s very important to debug the new stove. Through the comprehensive
system test of equipment, we can ensure function and safety performance of
products. Discovering any potential problems before use (such as equipment’s
placement, ventilation, operation, etc), can avoid costly losses.
7. Safety Notices and Precautions
⚠ Warning! For your safety, do not place petrol and other flammables
nearby. Please keep clean and free of flammables surroundings. (Read ANSI
Z83.14B, 1991 for reference)
⚠ Warning! Any erroneous installation, adjustment and refit may cause
property damage or personal injury and maintenance failure. Read the
instructions carefully before installation and using.
⚠ Warning! Operation instruction must be placed in a conspicuous location.
When customers smell gas in the process of using, should take safety
precautions immediately. Immediately turn off the main gas valve, extinguish
all heat and flames, and call 911. Safety information can be obtained from
your local gas suppliers.
When using this equipment, safety precautions should always be followed,
including the following:
⚠ The Heavy Duty Stock Pot Stove burners, cooking grates and outside
surfaces may become hot after use, so you must be careful to touch;
⚠ During operation, do not directly touch burners and cooking grates;
⚠ Turn off the equipment as repairing, maintaining and cleaning;
⚠ If the equipment has any problems of equipment damage, gas piping
leaks, igniter or valves damage, or lose product accessories, do not operate,
and call for the service immediately;
⚠ The use of attachments not recommended or sold by the manufacturer may
cause fire, personal injury or even death;
⚠ Do not use out of doors;
⚠ The equipment is used for cook, not available for any other use;
⚠ The equipment does not contain any user-serviceable parts. Dealers or
technicians will repair it. Do not take apart any spare parts without
authorization;
⚠ Never change any other parts without authorization to this equipment,
otherwise, may cause hazards, and the manufacturer has the right not to
provide warranty service;
⚠ Steel cutting producers used to manufacture with sharp edges. The
manufacturer has dealt with these sharp edges during production, however, we
insist the operator take care when in contact with this piece of equipment;
⚠ Always keep hands, hair and clothing away from heating source.
⚠ Wait the unit cools down before cleaning. Because the unit is too hot
to handle after using.
8. Operating Instructions
⚠ Before operating, make sure to place the unit horizontally by adjusting
bottom adjustable legs, and place the catch tray properly.
⚠ The pilot light has been set at the factory. Each burner has a pilot
light.
8.1 Lighting the pilot light
Turn the control valve at the position of “0”(Fig.2), make sure all
knobs are in the close state. Light and hold an ignition source at the pilots.
The pilot light may not be lighted immediately, for existing gas in the pipe.
Wait a minute, the pilot light will be lighted after the gas extinguished.
Tips: You can use a screwdriver to adjust the height of the flame (Fig.3).
8.2 Igniting the main burner
Revolve the main fire control valve knob anticlockwise after lighting
the pilot light, then the main fire burner is lighted by the pilot light. The
power of burner increases as revolving angel increases. When knob reaches to ”
“, burner is in the maximum power (Fig.4).
Reminder: Turn on the knob controlling inner ring burner first, then turn on the main fire valve, as shown in Fig.5, and 6.
⚠ Make sure air circulation at the bottom of equipment;
⚠ Do not use fan or air-conditioning blowing at the flame, in order to avoid
extinguishing flame and cause safety accidents;
⚠ Install the matched cooking fume exhauster according as the local
regulations over the char broiler;
⚠ Make sure to keep the air natural circulation in the kitchen.
8.3 Turn off the valve
Revolve the control valve knob clockwise to “0” (Fig.1), so that
extinguish flame of the main burner, but the pilot light still works. After
turn off the equipment, the main fire should be stop more than 5 minutes
before next use.
8.4 Stove Operation
Before using the stove for the first time, please use a mild detergent to wipe
it clean. Do not use corrosive or abrasives detergent. Turn the burners on
about 15-20 minutes before broiling for preheating, according to the cooking
requirement to adjust the flame size.
Notice: When first preheating, the furnace will smoke above. This is caused
by protective lipids on the grates and other parts are heated, it is normal,
and it will be eliminated after the power up to the maximum for burning an
hour.
8.5 Exchange main fire nozzle to switch gas source
Remove control panel, cooking grates, the pilot light head, and burner, remove
main fire nozzle with proper open spanner, exchange nozzle of another gas
source, then screw it (Fig.8). Reinstall burner, the pilot light head, cooking
grates and control panel in proper order.
⚠ Caution: Each main fire orifice of the burner has been installed before
delivery, normal use without adjustment but only switching gas. Adjust only by
authorized and licensed technicians. When you converse the gas source,
exchange the corresponding pressure maintaining valve which installed on air
intake. See 5 in P18.
8.6 Adjust air input
Remove control panel, unscrew damper solid screw(Fig.8), revolve damper
left to right(Fig.9), meanwhile, observe flame, to adjust an appropriate
opening degree. Then screw damper solid screw, make sure the equipment will
not get loose in the process of moving and translation. Reinstall control
panel.
⚠ Caution: Each burner damper has been adjusted before delivery (once air input), Normal use without adjustment but only switching gas. Adjust only by authorized and licensed technicians.
9. Cleaning and Maintenance
⚠ Do not use any abrasive or flammable detergent to wipe;
⚠ Do not hose down, immerse or pressure wash any part of the cooker, excluding
the catch tray;
⚠ Do not use abrasive cleaning matters to wash, even not use corrosive
detergent!
⚠ Warning: Before cleaning, all control valves must be turned off. Strictly
follow the lighting instructions to work again after cleaning!
⚠ Warning: Wait for the equipment to cool down after the unit has been
turned off before you clean!
⚠ Cut off the gas source when not in use;
⚠ If the equipment is not used for a long time, clean the surface by wiping it
with a soft cloth and place it in a well-ventilated area;
⚠ Comprehensively check the equipment at least once every year by authorized
and licensed technicians;
⚠ The product is made of 90% metals, and can not be discarded everywhere. Deal
with it in accordance with the local codes.
⚠ Instructions to clean appliance regularly with recommended cleaning agents,
if necessary.
Recommended cleaning methods
10. Troubleshooting
The problems mentioned above are only for reference. If any fault occurs, please stop using, and contact technicians to check and repair. Safety first, turn off the power and gas supply before maintenance.
11. Spare Parts
⚠ The use of parts provided by other companies, our company has the right
not to provide warranty service;
⚠ Order replacement parts from authorized representatives and after-sale
service agency.
⚠ Provide the model number, serial number and description when you order
components.
12. Accessories List
Notice:
- Pressure maintaining valve connects with air intake, must be installed by authorized and licensed technicians, to ensure interface tightness.
- The pressure regulator(s) have connected, the maximum load of natural gas cannot exceed 6″, and of LP cannot exceed 12″.
- Adjustment range of the pressure regulator(s) is 4″-6″for natural gas, and 7″-10″for L.P..
- Screw the hex nut (Fig.11) before connect air intake, ensure gas mark (Fig.12) on the plastic core whether match with connected gas source, if not, then pull out the plastic core and change another head, insert it again. The same as exchanging gas source.
- When exchange gas source, use the A18 orifice (Fig.13) in the accessories. Follow rules of 8.5.
Our products have the advantages of good durability and low maintenance charge. But to update some components and necessary maintenance, can prolong life length of the products. Contact the dealer for assistance. In order to avoid confusion, please follow the format in figure 10 and table 4.
Migali (R) Industries, Inc. Trusted Since 1955
516 Lansdowne Ave
Camden, NJ 08104
Service Call: 800.852.5292
Service Email: warranty@mgiali.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>