Read and follow the operating instructions and safety information before using
for the first time. Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical
data can differ insignificantly. Updating the documentation
If you have suggestions for improvement or have found any irregularities,
please contact us.
The information contained in this document may alter at any time without
previous notice. It is prohibited to copy or spread any parts of this document
in any way without prior written allowance. All rights reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible
mistakes in this operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible
efforts to ensure that the operating manual is complete, faultless, and up to
date, mistakes cannot be entirely avoided. If you should find a mistake or
wish to make a suggestion for improvement, we look forward to hearing from
you.
Send an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in
our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
To return orders for exchange, repair, or other purposes, please use the
following address. Attention!
To allow for a smooth execution of your complaint or return, it is important
to contact our customer service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
Introduction
Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Keep these operation instructions safe.
Features
- Pump body, pump cover and impeller are made of high-quality plastic
- Big outlet, high lift, low noise
- Good mechanical seal and durable.
- With over load protection to ensure long lasting working
- With simple suction and discharge pipes.
Application
These water pumps are designed for the circulation and filtration of the small swimming pools (family use), whirl pools and Sauna pools.
Caution!
- For swimming pools and garden ponds and in its protection zone, the use of the pump is only permitted with fault current circuit breaker (30 mA) according to DIN VDE 100 part 702 06.92. Please contact a qualified electrician if you have any questions.
- Keep a safe distance to the pool and fix the pump on a stable base plate. According to VDE standard is observed a safety distance of 2 m.
- The pump has a built-in motor protection switch. We do not take over any liability for losses through unsuitable use or faulty assembly. The power cable must conform to EC standards (2) or the type H07 RN-F according to VDE 0620
Checks before start-up
- Make sure that the voltage and frequency of power supply and pump (see nameplate) are suitable.
- Make sure that the pump shaft may rotate freely.
- Fill the pump with water to make sure that the pump body, filter basket, pipes and other connectors are not leaking. Tighten or loose the screws with hands, or tolls if necessary.
- Open any existing valves in pressure and suction lines and check that all hoses are connected.
- Please fill the suction pipe and the pump body completely with water.
- The pump is suitable for clean water with a temperature of max. 35 ℃.
Power supply
Use the pump only on a three-pole socket with 230 V/50 Hz
Mounting
- To avoid long suction lines and the resulting power losses the pump should be installed at the level of the water table or below the water level.
- It is possible to assemble the pump to the ground. Please use the provided holes in the base plate to install the pump on a flat surface.
- The pumps shall be placed in a well ventilated, dry, and flood-proof place.
Placing the hoses
- The suction hose must be low pressure resistant. Please install it at least 30 cm below the water level. This is necessary to avoid vortex formation and through this caused air inlet in the system.
- The pipe connections must be 100 % airtight. Pipe bends and a wavy placing of the hoses must be avoided if possible. The sucking line should have a minimum descent of 2 % on its complete length so that no air can remain in the system.
- The pressure hose should have a diameter at least as large as the diameter of the pressure joint.
- The hoses may not lay on the pump. Make sure that all connections are tight so that the pumpdoes not come in contact with moisture. The pump could be damaged through water!
Start-up
- Fill the pump with water to make sure that the pump body, filter basket, pipes and other connectors are not leaking. Tighten or loose the screws with hands, or tolls if necessary.
- Open any existing valves in pressure and suction lines and check that all hoses are connected.
- Please fill the suction pipe and the pump body completely with water.
- Plug in the pump and check that the water pump circulates.
- If the pump is used above the water level of the pool, you must use a foot valve at the suction hose to avoid that the water runs back in the pool when you do not use the pump.
- Switch of the pump, when the engine does not start or not water is promoted. In this case check if something is blocking the water flow.
- Do not run the pump without water in the pump body. This would damage the mechanical seal and in this case the pump would leaking.
- Please do not work on the pump while the pump is running!
- If you have any problems which are not mentioned in the manual or which you could not explain please contact an expert.
Maintenance
Our electric pumps require no special maintenance. Please clean regularly the
dirt container. During the cold season, and at longer shut-down of the pump
the pump body should be emptied. Please clean the pump thoroughly with clean
tap water to remove all residues of chlorine and other pool stuff. If you do
not clean the pump thoroughly this could damage the seal and causes leaks when
you use the pump again.
Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE,
2012/19/EU) were implemented in the law related to electrical and electronic
equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled
with the crossed-out wheeled waste bin logo. This logo indicates that this
electric equipment must not be disposed with the domestic waste
The company WilTec Technik GmbH has been registered in the German registry EAR
under the WEEEregistration number DE45283704.
Disposal of used electrical and electronic appliances
(intended for use in the countries of the European Union and other European
countries with a separate collection system for these appliances).
The logo on the article or on its packaging points out that this article must
not be treated as normal household waste but must be disposed to a recycling
collection point for electronic and electrical waste equipment.
By contributing to the correct disposal of this article you protect the
environment and the health of your fellow men. Environment and health are
threatened by inappropriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local
community, municipal waste disposal facilities, or the store where you
purchased the article.
Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in
part, of this instruction manual require the written permission of WilTec
Wildanger Technik GmbH.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>