Product Information
Product Name: Portable Ventilators with Ducting
Model Number: VEN200.V3
Manufacturer: Sealey
This product is designed and manufactured to a high standard, ensuring reliable and trouble-free performance when used correctly and maintained properly. Please read the following instructions carefully, noting the safe operational requirements, warnings, and cautions. It is essential to use the product correctly and with care for its intended purpose to prevent damage, and personal injury, and to maintain the warranty. Keep these instructions safe for future reference.
Product Usage Instructions
Electrical Safety
It is the user’s responsibility to ensure electrical safety by following
these guidelines
- Inspect all electrical equipment and appliances for safety before use.
- Check power supply leads, plugs, and connections for wear or damage.
- Sealey recommends using a Residual Current Device (RCD) with all electrical products.
- If using the product for business purposes, maintain it in a safe condition and routinely perform Portable Appliance Testing (PAT).
- Before connecting the appliance to the power supply, ensure the insulation on all cables and the appliance is safe.
- Regularly inspect power supply cables, plugs, and connections for wear or damage.
- Ensure the voltage rating on the appliance matches the power supply and the plug has the correct fuse rating.
- Avoid pulling or carrying the appliance by its power cable.
- Avoid pulling the plug from the socket by the cable.
- Do not use worn or damaged cables, plugs, or connectors. Repair or replace any faulty items immediately with the help of a qualified electrician.
- This product is fitted with a BS1363 3-pin plug.
- If the cable or plug is damaged during use, switch off the electricity supply and discontinue use. Seek repairs from a qualified electrician.
- Replace a damaged plug with a BS1363 3-pin plug. If unsure, consult a qualified electrician.
- When connecting the appliance, follow these guidelines:
- Connect the GREEN/YELLOW earth wire to the earth terminal `E’.
- Connect the BROWN live wire to the live terminal `L’.
- Connect the BLUE neutral wire to the neutral terminal `N’.
- Ensure the cable’s outer sheath extends inside the cable restraint and is tight. Sealey recommends repairs by a qualified electrician.
- Replacement fuse rating: 3A
General Safety
Follow these general safety instructions when using the ventilator
- Disconnect the ventilator from the main’s power when not in use or before servicing/maintenance.
- Use the fan in dry areas only and avoid wet or high-condensation locations like bathrooms, showers, or pools.
- WARNING: If the ventilator falls into water, immediately switch it off and disconnect it from the main power supply.
- DO NOT touch the ventilator until disconnected.
- Always disconnect the ventilator from the power supply when moving it between locations.
- Keep the ventilator clean and maintain in good condition (use an authorised service agent).
- Use recommended parts only (unauthorised parts may be dangerous, and will invalidate your warranty).
- DO NOT stand the ventilator where it may be knocked over or off a surface, or where the lead may cause a trip hazard.
- DO NOT use an extension cord unless it has been approved by an electrical authority.
- DO NOT insert any objects through the fan guard.
- DO NOT allow children to operate the ventilator.
- DO NOT immerse the ventilator in water or any other liquid.
- DO NOT use the ventilator outdoors.
- DO NOT cover the ventilator.
- When not in use store in a safe, dry, childproof location.
INTRODUCTION
Ideal for use where high-volume clean air delivery is required. Especially designed to easily ventilate hot or fume laden work areas, creating a cleaner and more pleasant working environment. Supplied with 5m ducting (VEN200AK1). Optional 10m ducting (VEN200AK2) available, but not supplied. The air mover/ventilator can be used across multiple industries including, but not exclusive to; marine, roof spaces and building sites, cable/pipe ducts and workshops. Light weight in construction with large carry handle makes it easily portable. Fitted with 2m cable and 3-pin plug. Ducting supplied is compatible with other leading manufacturers products with Ø200mm.
SPECIFICATION
- Model no……………………………………………………….. EN200.V3
- Fan diameter……………………………………………………… 200mm
- Fan speed……………………………………………………….. 2800rpm
- IP rating………………………………………………………………… PX4
- Power………………………………………………………………….. 115W
- Replacement parts……………………… EN200AK1/VEN200AK2
- Static pressure………………………………………………….. 3.1mbar
- Supply……………………………………………………………………….. V OPERATION
- Decide on the direction of air flow, depending on your requirement (ventilate or extract). See fig 1 for direction of air flow. Ducting can be attached to either end of the ventilator depending on whether you wish to remove/extract fumes or deliver fresh air into a work space.
- To change direction of air flow rotate the unit 180° as the air flow is a fixed direction.
- Secure ducting by pulling the string tight then move the toggle switch to start the unit; select a low or high fan speed as required.
- NOTE: The ducting has locating lugs attached to it; these can be used to suspend the ducting if required.
DIAGRAM SHOWS VENTILATION OPERATION
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice. Please note that other versions of this product are available.
If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk www.sealey.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>