QSFPTEK S5300-48P6X 48-Port Gigabit Ethernet L2 Plus Plus PoE Plus Switch User Guide

June 12, 2024
QSFPTEK

QSFPTEK S5300-48P6X 48-Port Gigabit Ethernet L2 Plus Plus PoE Plus Switch

QSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-Plus-PoE-Plus-Switch-
FIG- \(2\)

Product Information

The QSFPTEK S5300-48P6X is a next-gen aggregation switch designed for network implementation. It features 48x Gigabit Ethernet RJ45 ports, 6x 10 Gigabit Ethernet SFP+ uplink ports, and supports stacking of up to 8 S5300 series switches. The switch allows for interconnection and management of multiple switches as one logical unit.

Product Usage Instructions

Accessories

  • Screwdriver
  • Static-proof wristband
  • Bolt
  • Ethernet cable
  • Other Ethernet terminal devices
  • Control terminal

Installation Requirements

Before installation, ensure the following:

  • Keep the installation area dustless and clean.
  • Securely place the cover in a safe place.
  • Ensure tools are placed in a secure location.
  • Wear appropriate clothing to avoid accidents.
  • Use protective glasses if required.
  • Avoid incorrect operations that may cause damage.

Site Environment

To ensure proper functioning of the switch, consider theV following:

  • Ensure the workshop is well-ventilated to dissipate heat.
  • Follow electrostatic discharge prevention procedures to prevent damage.

Hardware Installation

  1. Place the switch in a location where cool air can circulate to dissipate heat.
  2. Ensure the machine box is sealed properly.

Mounting the Switch

Follow these steps to mount the switch:

  1. Plug the AC power cord into the switch power port on the rear.
  2. Connect the other end of the power cord to an AC power source equipment.

Connecting the RJ45 Port

  1. Connect one end of the Ethernet cable to the RJ45 port on networking equipment (e.g., PC, printer, server, storage).
  2. Connect the other end of the Ethernet cable to the switch RJ45 port.

Connecting the SFP+ Port

  1. Insert the SFP+ module into the SFP+ port.
  2. Plug a fiber patch cable into the SFP+ transceiver.
  3. Connect the other end of the fiber to the device for data communication.

Connecting the Management Ports

Connecting the Console Port

  1. Prepare a console cable.
  2. Insert the RJ45 connector of the console cable into the console port on the switch.
  3. Connect the D89 female connector on the other end of the console cable to the serial port on the computer host.

S5300-48P6X Quick Start Guide

  • 48-Port Gigabit Ethernet L2++ PoE+ Switch
  • 48x PoE+ Ports, with 6x 10GE SFP+, Support Stack

Introduction

  • The QSFPTEK S5300-48P6X is a next-gen aggregation switch, with 48x GE RJ45, 6x 10GE SFP+ Uplink. It supports stacking of up to 8 S5300 series switches, making them logically regarded as one switch for interconnection and management.
  • We appreciate your decision to select S5300-48P6X. This manual is intended to help you become acquainted with the switch design and provide instructions for implementing the switches into your network.QSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-Plus-PoE-Plus-Switch-FIG- \(3\)

Accessories

QSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-Plus-
PoE-Plus-Switch-FIG- \(4\)

Hardware Overview

Front Panel PortsQSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-
Plus-PoE-Plus-Switch-FIG- \(5\)

Ports Description

Gigabit port

| ****

RJ45 port, LINK/ACT indicators


10GE port

| ****

SFP+ port, LINK/ACT indicators

CON Port| ****

A baud rate of 9600bps, RJ45 port

Front Panel LEDsQSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-
Plus-PoE-Plus-Switch-FIG- \(6\)

LEDS Description

SWAP

| ****

Swap function, used to switch POE indication.


PWR LED

| ****

If the switch is powered on, the PWR indicator is on.


SYS LED

| ****

If the system is started normally, the SYS indicator flickers.


POE LED

| ****

Indicates whether the POE card is detected.

Back PanelQSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-Plus-PoE-
Plus-Switch-FIG- \(7\)

Abbrev Name Description

POWER

| ****

DC power supply

| ****

Input voltage 55VDC


/

| ****

Grounding column

| ****

The grounding must be fine.


ON/OFF

| ****


Power on-off

| ****

ON: means the power is on;


OFF: means the power is off.


POWER

| ****

AC power supply

| ****

Input voltage AC100-240V

Installation Requirements

Tools Preparation

  • Screwdriver
  • Static-proof wristband
  • Bolt
  • Ethernet cable
  • Other Ethernet terminal devices
  • Control terminal

Safety Principles

  • Keep dustless and clean during or after the installation.
  • Put the cover at the safe place.
  • Put tools at the right place where they are not easily falling down.
  • Put on relatively tight clothes, and fasten the tie or scarf well and roll up the sleeve, avoiding stumbling the machine box.
  • Put on the protective glasses if the environment may cause damage to your eyes.
  • Avoid incorrect operations that may cause damage to human or devices.

Site Environment

  • Make sure that the workshop is well-ventilated, the heat of electrical devices is well-discharged
  • Avoid to damage devices by following the electrostatic discharge prevention procedure. S5300-48P6X Hardware Installation Manual
  • Put the machine box at the place where cool air can blow off the heat inside the machine box. Make sure the machine box is sealed.

Mounting the Switch

Connecting the PowerQSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-
Plus-PoE-Plus-Switch-FIG- \(8\)

  1. Plug the AC power cord to the switch power port on the back rear.
  2. Connect the other end of the power cord to a AC power source equipment.

Connecting the RJ45 PortQSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2
-Plus-Plus-PoE-Plus-Switch-FIG- \(9\)

  1. Connect one end of the Ethernet cable to the RJ45 port on networking equipment, such as PC, printer, server, storage, etc.
  2. Connect the other end of the Ethernet cable to the switch RJ45 port.

Connecting the SFP+ PortQSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2
-Plus-Plus-PoE-Plus-Switch-FIG- \(10\)

  1. Insert the SFP+ module into the SFP+ port.
  2. Plug a fiber patch cable to the SFP+ transceiver.
  3. Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the Management Ports

Connecting the Console PortQSFPTEK-S5300-48P6X-48-Port-Gigabit-
Ethernet-L2-Plus-Plus-PoE-Plus-Switch-FIG- \(11\)

  1. Prepare an console cable.
  2. Insert the RJ45 connector of the console cable into the console port on the switch.
  3. Connect the D89 female connector on the other end of the console cable to the serial port on the computer host

Configuring the Switch

Configuring the Switch Using the Web-based Interface

  • Step 1 : Connect your computer to the switch using an Ethernet cable and open a web browser.
  • Step 2 : Set the IP address of the computer to 192.168.0.x (where “x” is any number from 2 to 254) and the subnet mask to 255.255.255.0.QSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-Plus-PoE-Plus-Switch-FIG- \(12\)
  • Step 3: Open a web browser and type http://192.168.0.2 in the address bar. Enter the default username and password (admin/admin).
  • Step 4 : Click sign-in to access the web-based configuration page.

Configuring the Switch Using the Console Port

  • Step 1 : Use the console cable to direct connect the switch console port to your computer.
  • Step 2 : Launch the terminal simulation software such as Hyper Terminal on the computer.
  • Step 3 : Configure the parameters of the terminal emulation software as follows: 9600 bits per second, 8 data bits, no parity, 1 stop bit, and no flow control.QSFPTEK-S5300-48P6X-48-Port-Gigabit-Ethernet-L2-Plus-Plus-PoE-Plus-Switch-FIG- \(13\)
  • Step 4: Enter the default username and password (admin/admin).

Troubleshooting

Hardware Fault Analysis

  • Power and cooling systems—power and fan
  • Port, cable and connection—ports on the front panel of the switch and the cables connecting these ports
  • Faults Relative with Power and Cooling System

Do the following checkups to help remove the fault:

  1. When the power on-off is at the “ON” location, check whether the fan works normally. If the fan does not work well, check the fan.
  2. If the switch is too hot, check whether the air outlet and air inlet are clean and then do relative operations in section 2.3 “Requirements for Common Locations”.
  3. If the switch cannot be started and the PWR indicator is off, check the power.

Faults Relative with Port, Cable and Connection

  • Do the following checkups to help remove the fault:
  • If the port of the switch cannot be linked, check whether the cable is correctly connected and whether the peer connection is normal.

If the power on-off is at the “ON” location, check the power source and the power cable.

If the CLI port does not work after the system is started up, check whether the CLI port is set to a baud rate of 9600 bps, eight data bits, no sum check bit, one stop bit and no traffic control.

Support and Other Resources

Product Warranty

  • S5300 series switches are backed by a 5-year limited warranty supported by QSFPTEK. And you are eligible to apply for a return or exchange of your items within 14 days of receiving them.
  • For more details about applying qualifications, please live chat or email sales@qsfptek.com for support

www.qsfptek.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

QSFPTEK User Manuals

Related Manuals