nuaire NTD-125 Ductmaster Thermal Ducting Installation Guide
- June 12, 2024
- Nuaire
Table of Contents
- nuaire NTD-125 Ductmaster Thermal Ducting
- Product Information
- Product Usage Instructions
- INTRODUCTION
- INSTALLATION
- Installation and Maintenance
- Fitting Clamps without Fixing Lugs
- TYPICAL MVHR DUCT ARRANGEMENT FOR 204 x 60mm
- SPARES & SERVICE ENQUIRIES
- Range Details 125mm dia. Ducting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
nuaire NTD-125 Ductmaster Thermal Ducting
Product Information
- Product Name: Nuaire Ductmaster Thermal Ducting (NTD)
- Product Description: NTD is a range of ducting and ancillaries designed for installation in domestic properties. It features a unique ducting design that eliminates the need for solid plastic inner ducting to achieve the required thermal properties and leakage rates stipulated by building regulations. The thermal ducting clamps connect system is specifically designed for use with Nuaire Thermal Ducting, allowing quick and easy installation without the need for tapes or sealants.
Features:
- Unique ducting design eliminates the need for solid plastic inner ducting
- Meets required thermal properties and leakage rates
- Quick and easy installation
- No need for tapes or sealants
Product Usage Instructions
Installation
- Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory governing regulations.
- The ducting should be installed indoors, on a suitable vibration-free solid surface, away from direct sources of frost, heat, water spray, or moisture generation.
- Prior to installation, perform a dimensional check of the chosen installation location to ensure suitability.
Note: Do not place heavy objects on the ducting as this could cause distortion or breakage, resulting in air flow leakage at the seal joint with the connector.
Use of Thermal Ducting Clamps
Thermal ducting clamps with fixing lugs must be used on the duct bends and
T pieces as shown in the figures below:
Rectangular Ducting:
Round Ducting:
Use of Flexible Duct Connections with Thermal Plenums and Bends
If using semi-rigid acoustic flexible duct between the MVHR unit and a
plenum or bend, ensure that a rigid 125mm dia. PVC duct connector is installed
into the plenum or bend for successful connection.
Note: Maximum length of semi-rigid acoustic flexible duct should not
exceed 300mm.
Installation of a Condensation Trap in Thermal Ducting
Figure 6 shows the use of a condensate trap (Code Contrap125) with rigid
PVC duct connectors (Code PVC593WH).
Installation of an Attenuator in Thermal Ducting
Figure 7 shows the use of an attenuator with rigid PVC duct connectors
(Code PVC593WH).
For further assistance, please contact Nuaire at +44 2920
858400 or visit
www.nuaire.co.uk.
**NTD-125/204/220-***
NTD 2 piece lugged connector with Ductmaster Rectangular and circular Thermal
Ducting Installation and Maintenance Manual
INTRODUCTION
- Nuaire Ductmaster Thermal Ducting (NTD) is a range of ducting and ancillaries intended for installation in domestic properties.
- Nuaire Thermal Ducting is available in three different sizes and profiles, based on the internal dimension: 125 mm Ø or 204 x 60 mm and 220 x 90 mm rectangular.
- Unlike other thermal ducting systems Nuaire’s unique ducting design negates the need for solid plastic inner ducting to achieve the required thermal properties and leakage rates stipulated by building regulations.
- Nuaire’s thermal ducting clamps connect system is designed to use with Nuaire Thermal Ducting and allows quick and easy installation without the need for any tapes or sealants.
- Using Nuaire thermal ducting will achieve a level of leakage substantially lower than the maximum allowed for a class ‘A’ duct as defined in DW/143 (Ductwork leakage testing).
INSTALLATION
- Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory governing regulations.
- The ducting must be installed indoors, on a suitable vibration free solid surface away from direct sources of frost, heat, and water spray or moisture generation.
- Prior to installation a dimensional check of the chosen installation location should be undertaken to ensure suitability.
IMPORTANT
Do not place heavy objects on the ducting as this could cause distortion or
breakage. Distorted ducting could result in air flow leakage at the seal joint
with the connector.
IMPORTANT
Nuaire Thermal Ducting is supplied in 1 meter lengths. If shorter lengths are
required the duct can be cut to the desired length (see section 4.0)
Thermal Ducting Clamps
Nuaire thermal ducting clamps are available in 2 options to match 125 mm Ø or
204 x 60 mm or 220 x 90 mm rectangular duct. All types are with or without
fixing lugs.
IMPORTANT
Thermal ducting clamps with and without fixing lugs must be used on the duct
bends and T pieces as shown below.
Installation and Maintenance
Use of Flexible Duct Connections with Thermal Plenums and Bends
Where it is necessary to use semi-rigid acoustic flexible duct (max length
300mm) between the MVHR unit and a plenum or bend please ensure that a rigid
125mm dia. PVC duct connector is installed into the plenum or bend for
successful connection.
Use of Flexible Duct Connections Between Air Valves and Plenums / Bends
Installation of a Condensation Trap in Thermal Ducting
Installation of an Attenuator in Thermal Ducting
4.0 Cutting Ducting Lengths
A flush, square 90 cut is required to ensure that an air tight seal is made
with centre ridge in the clamp. If an angled cut is made, this will not allow
the duct clamps to create a seal on the duct. We advise that the duct is cut
with a very sharp blade or fine toothed saw (we recommend a minimum of 14
teeth per inch). The cutting blade length should be at least the same length
as the wall thickness of the ducting.
Ensure duct is placed into Duct Clamp connector prior to installation to check
the squareness of the cut ducting.
IMPORTANT
Nuaire Thermal Ducting is supplied in 1 metre lengths. If shorter lengths are
required the duct can be cut to the desired length with a fine toothed saw.
(We recommend a minimum of 14 teeth per inch). Failure to make a square cut
may result in air flow leakage when connecting to other ducting pieces. Ensure
duct is placed into Duct Clamp connector prior to ins tallion to check the
squareness of the cut ducting (figs. 9 and 10).
Fitting Clamps with Fixing Lugs
IMPORTANT
Only clamps with fixing lugs (NTD-204-CONL) and (NTD-125-CONL) should be used
for fitting / securing duct to the installation surface.
Establish the installation position for the ducting and clamps with lugs and drill 2 holes to suit the clamp position.
Having drilled 2 fixing holes to suit the clamp position, remove the top half
of the clamp from the bottom half. Using appropriate fixings fix the top half
of the clamp to the solid surface (fixings supplied by others).
Having drilled 2 fixing holes to suit the clamp position, remove the top half
of the clamp from the bottom half. Using appropriate fixings fix the top half
of the clamp to the solid surface (fixings supplied by others).
For final installation into the clamp, push the duct up into the duct clamp
fixed to the solid surface. The centre joint of the 2 duct lengths should be
located on the centre ridge of the clamp. Take the bottom half of the clamp
and push up so that the fixing tabs on each side fit into the slots on the
female half, then press together. Ensure the ducting is fully pressed into the
clamp to create an air tight seal. Failing to do so may cause air leakage.
Fitting Clamps without Fixing Lugs
- The clamps without fixing lugs (NTD-204-CON or NTD-220-CON) and (NTD-125-CON) should only be used to connect two ducting items together; they should not be used for installing duct to any surface.
- Straight runs of Nuaire white plastic ducting should be supported by either clip type PVC122-5WH or PVC coated steel banding every 1.0m (maximum).
- Straight runs of Nuaire Thermal Duct should be supported every 1.0m (maximum) if using PVC coated steel banding or when using Clamps with Mounting Lugs (Types NTD-204-CONL, NTD-125-CONL, NTD-220-CONL).
- With both thermal ducting or rigid ducting systems, care should be taken to ensure that bends, T-pieces, transitions, and plenum sections are also adequately supported by at least one lugged clamp/PVC clip/banding support, as applicable.
- When banding is used, ductwork support locations should ideally be at the midpoint between clamps.
TYPICAL MVHR DUCT ARRANGEMENT FOR 204 x 60mm
SPARES & SERVICE ENQUIRIES
Spare parts and replacement components are available from Nuaire. Please
contact us for further details.
Our Technical Support department will be happy to provide any assistance
required, initially by telephone and if necessary, will arrange for an
engineer to call.
Telephone 029 2085 8400
technicalsupport@nuaire.co.uk
Range Details 125mm dia. Ducting
INSULATED “T” PIECE
Part Number | Duct Size | Description |
---|---|---|
NTD-125-TP | 125mm Ø | Insulated T Piece |
INSULATED 90° BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-125-90H | 125mm Ø | Insulated 90° Bend |
INSULATED 45° BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-125-45H | 125mm Ø | Insulated 45° Bend |
INSULATED DUCT 1M LENGTH
Part Number | Duct Size | Description |
---|---|---|
NTD-125-1M | 125mm Ø | Insulated Duct 1m Length |
ROUND DUCT CLAMP FOR INSULATED DUCT
Part Number | Duct Size | Description |
---|---|---|
NTD-125-CONL | 125mm Ø | One Piece Connector & Duct Clamp |
NTD-125-CON | 125mm Ø | One Piece Connector & Duct Clamp |
Range Details 204 x 60 mm Ducting
INSULATED “T” PIECE
Part Number | Duct Size | Description |
---|---|---|
NTD-204-TP | 204mm x 60mm | Insulated T Piece |
INSULATED 90° HORIZONTAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-204-90H | 204mm x 60mm | Insulated 90° Horizontal Bend |
INSULATED 45° HORIZONTAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-204-45H | 204mm x 60mm | Insulated 45° Horizontal Bend |
INSULATED 90° VERTICAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-204-90V | 204mm x 60mm | Insulated 90° Vertical Bend |
INSULATED 45° VERTICAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-204-45V | 204mm x 60mm | Insulated 45° Vertical Bend |
INSULATED PLENUM
Part Number | Duct Size | Description |
---|---|---|
NTD-204-PL | 204mm x 60mm | Insulated Plenum |
INSULATED DUCT 1M LENGTH
Part Number | Duct Size | Description |
---|---|---|
NTD-204-1M | 204mm x 60mm | Insulated Duct 1m Length |
RECTANGULAR DUCT CLAMP FOR INSULATED DUCT
Part Number | Duct Size | Description |
---|---|---|
NTD-204-CONL | 204mm x 60mm | One Piece Connector & Duct Clamp |
NTD-204-CON | 204mm x 60mm | One Piece Connector & Duct Clamp |
Range Details 220 x 90 mm Ducting
INSULATED “T” PIECE
Part Number | Duct Size | Description |
---|---|---|
NTD-220-TP | 220mm x 90mm | Insulated T Piece |
INSULATED 90° HORIZONTAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-220-90H | 220mm x 90mm | Insulated 90° Horizontal Bend |
INSULATED 45° HORIZONTAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-220-45H | 220mm x 90mm | Insulated 45° Horizontal Bend |
INSULATED 90° VERTICAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-220-90V | 220mm x 90mm | Insulated 90° Vertical Bend |
INSULATED 45° VERTICAL BEND
Part Number | Duct Size | Description |
---|---|---|
NTD-220-45V | 220mm x 90mm | Insulated 45° Vertical Bend |
INSULATED PLENUM
Part Number | Duct Size | Description |
---|---|---|
NTD-220-PL | 220mm x 90mm to 125mm Ø | Insulated Plenum |
INSULATED PLENUM
Part Number | Duct Size | Description |
---|---|---|
NTD-220-PL150 | 220mm x 90mm to 150mm Ø | Insulated Plenum |
INSULATED DUCT 1M LENGTH
Part Number | Duct Size | Description |
---|---|---|
NTD-220-1M | 220mm x 90mm | Insulated Duct 1m Length |
RECTANGULAR DUCT CLAMP FOR INSULATED DUCT
Part Number | Duct Size | Description |
---|---|---|
NTD-220-CONL | 220mm x 90mm | Duct Clamp with Fixing Lugs |
NTD-220-CON | 220mm x 90mm | Duct Clamp withuot Fixing Lugs |
INSULATED 220 x 90 TO 204MM REDUCER
Part Number | Duct Size | Description |
---|---|---|
NTD-220-RED204 | 220 90 to 204mm x 60mm | Insulated 220 x 90 to 204mm Reducer |
INSULATED 220 x 90 TO 125MM DIAMETER ADAPTOR
Part Number | Duct Size | Description |
---|---|---|
NTD-220-STR125 | 220 x 90 to 125mm Dia. | Insulated 220 x 90 to 125mm |
Rectangular to Round In-line Adaptor
INSULATED 220 x 90 TO 150MM DIAMETER ADAPTOR
Part Number | Duct Size | Description |
---|---|---|
NTD-220-STR150 | 220 x 90 to 150mm Dia. | Insulated 220 x 90 to 150mm |
Rectangular to Round In-line Adaptor
nuaire.co.uk
26. 04. 23. Leaflet Number 671620