CR021R
(Art-Net-DMX512 Network Converter) ****
Ver1.0
Introduction
CR021R is standard Art-Net Node. Because of this, you can use the device with any application, console, or controller that supports Art-Net to distribute Art-Net data via Ethernet network. Commonly the CR021R can be used to extend the DMX output ports of tiger touch and MA2.
Parameters
Type| Parameters| Modify yes/not|
Configuration methods
---|---|---|---
Art-Net Equipment Name| CR021R| ?| DMXWorkShop
Default IP Address| 10.201.6.100| ?| LCD Menu
Art-Net Broadcast Address| 10.255.255.255| ?| LCD Menu
Subnet Mask| 255.0.0.0| ?| LCD Menu
MAC address| d-4d-48-c9-06-64| ?| LCD Menu
Support Art-Net Protocol| Art-Net I, Art-Net II, Art-Net III| ?|
DMX512 Port Address| Net: 0, Subnet: 0,
Universe: 0-15| ?| LCD Menu
NIC Speed| 100Mbps| ?|
DMX512 output| 2 universe| ?|
DMX512 Channels| 2 x 512| ?|
LED(R-G-B)Pixels| 2x 170| |
Power Supply 1| AC90-240V/50-60Hz| |
Power Supply 2| International POE,DC48V| |
DMXWorkShop| PC Software| ?|
Panel Introduction
NO.| Type|
Function
---|---|---
1| Power Indicator: White LED| Show the power connection state
2| DMX512 signal indicator: Blue LED| DMX512 data running state
3| Art-Net data running indicator: White LED| data running state
4| Art-Net Connector Indicator: White LED| Physical link state
5| Menu button| Into set up state and set up selection
6| Up button| Parameter input
7| Down button| Parameter input
8| Enter button| Parameter change(short press) and save(long press)
9| LCD display| Through the LCD menus to manually set the system parameters,
If LCD backlight has not button operation, automatic shut down after 5
minutes.
10| 2pcs 3-XLR| Output DMX 512 signal
Introduction of the lower side plate
Number
| Type|
Function
---|---|---
1| AC220V Power Supply Socket| AC90-240V/50-60Hz
2| Internet RJ45 port| Art-Net input, International POE, 48V input
Introduction of upper plate(Installation 1)
Hook mounting holes(M10Screw hole)
The effect of hook installation
Introduction of both side(Installation 2)
screw mounting holes on both sides, which can be fixed with screws
Configuring System Parameters
Table 1 – Button instruction
Key|
| | | ****
---|---|---|---|---
Function| Menu (cancel)| UP| Down| Enter (save)
Table 2 – The steps for setting the parameters
The buttons operation steps for setting each Art-Net parameter, as follows:
steps|
instruction
---|---
1| Press the [MENU] to choose and switch the parameter menu;
2| Press the [ENTER] to edit the parameter menu,(then Appears
blinking cursor)
3| Press the [ENTER] , can switch the specific parameter (the
parameter at the blinking cursor wasthe one already choose)
4| Press [UP] or [DOWN] ,can modify the current parameters; Long
press [UP]or [DOWN] for 1S to quickly modify the current parameters
5| Long press the [ENTER] for more than 1S ,system will save the
modified parameters . If the info was wrong, it will not be saved, then press
[ENTER] to clear the wrong info, also can enter the values follow the
presentation and save again.
Table 3 – The menu presentation for output mode(the form contents to factory default values)
Menu| DMX output mode|
Default values
---|---|---
1| IP address|
2| Subnet Mask|
3| Output Port universe|
4| Output Port net| < Port Net>| Net: 000
5| Output Port subnet| < Port Sub-Net>| SubNet: 00
6| Ethernet MAC|
7| Default Set|
Table 4 – Sets the error information table
Menu item | LCD display the error info | The instruction for the error info |
---|---|---|
Set the local IP & subnet mask | !!Local IP: hosted can’t is 0!! | Local IP host |
number is not 0
! Local IP hosted can’t all is 1!| Local IP host number is not 1
Set the input route| !!Port Universe can’t be same!!| The different DMX input
ports must be only
Set the transmit mode| “!!NO AD4 KEY!!”| Didn’t get to the correct encryption
information
Table 5 – Recommended network settings:
IP Address| Subnet Mask|
Broadcast Address
---|---|---
2.x.x.x| 255.0.0.0| 2.255.255.255
10.x.x.x| 255.0.0.0| 10. 255.255.255
192.168.x.x| 255.255.255.0| 192.168.x.255
Table 6 – Art-Net Network working conditions
1 | Network devices have the same subnet mask | 255.x.x.x |
---|---|---|
**** 2 | **** Network devices have the same network segment and unique IP | |
address | 2.x.x.x |
10.x.x.x 192.168.x.x
3| Correct port address: Net+Sub-Net+Universe| 000 + 00 + ( 0…15 )
4| Network device has a unique MAC address| d-4d-48-c9-06-64
5| Network equipment is used with crossed cable, router, switchboard, and
connect multiple network devices| crossed cable, router
Table 7 -Port addresses definition
Port addresses | Net | Subnet | Line |
---|---|---|---|
Port Address | Net (0-127) | Subnet (0-15) | Universe (0-15) |
Table 8 -Attention about setting parameters
NO.
| Menu item|
Pay attention to the items
---|---|---
1| Setting IP address| Each network set must have a unique IP address (not
Other network equipment occupancy) and the same subnet mask, otherwise will
cause the network does not work.
2| Setting subnet mask| The subnet mask is 255.x.y.z, do not need to modify x,
y, z one by one, we provide the subnet mask from menu table, there are 23
subnet mask which may be used, select the subnet mask that you want to set
code on it.
3| Setting port of subnet address| Each network (Net) of Art-Net includes 16
(universe) The range is 0-15.
4| Setting port of network address| Each network (Net) of Art-Net includes 256
route (universe), Settings range from 0-127,
5| Setting the NIC’s MAC address| Each network device have a network card,
each card must have Unique MAC address d-00-22-a8-00-64, and the last 3 values
of this card’s MAC address already have been binding with the last 3 values of
IP address, can effectively prevent the collision about the MAC address. If
there is NIC conflict, the user can modify the second, the third bytes of the
MAC address.
6| default set| CR051R support default set, If you want to reset, all the
parameters which have been kept before, will modify the original parameters,
include the transmission mode , input mode also will be converted to output
mode, and the network parameter, Port addresses will be initialized to default
values.
Application 1:LED matrix screen driver
Equipment | Function |
---|---|
PC computer | Running Jinx!-LED Matrix Control |
CR041R internet converter | Convert the Art-Net to 2ways DMX 512 |
Dmx512 Decoder(LED Decoder) | Convert the DMX512 to the signal of RGB LED strip |
RGB LED trip(Assemble to the Matrix screen) | 300pcs dot ,R,G,B ,3 channels |
Size of the Matrix | 20 x 17 |
Switch power (support power to the RGB LED trip) | 5V – 40A -200W |
Equipment connection blocks diagrams:
Application 2:The control lighting system from the Art-Net port to
control the Dmx 512 lighting equipment
Equipment|
Function
---|---
Art-Net lighting controller equipment| Running Jinx!-LED Matrix Control
CR021R internet converter| Convert the Art-Net to 2 ways DMX 512
Dmx512 lighting equipment| Receive the DMX512 signal to show the lighting
effect
Equipment connection blocks diagrams:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>