Overview:

Altronix NetWaySP1BT and NetWaySP1BTWPN 802.3bt media converter/injectors provide a single 802.3bt (4PPoE) port up to 90W and accommodate Fiber (1000Base-X/SX/LX) or structured cable to transmit data. Units can be deployed with structured cable, conventional single/multimode fiber or composite cable (fiber + copper combined). Cameras/edge devices may be located up to 100m from the unit.

Features:

Agency Listings:

  • CE European Conformity.

Input:

  • 48-56VDC @ 1.9A (95W).
  • See below for recommended Power Sourcing Equipment.

Fiber Port:

  • One (1) 1Gb SFP port.
    ** See below for recommended SFP modules.

PoE Port:

  • Single port rated up to 90W max.
  • IEEE 802.3af, 802.3at and 802.3bt compliant.

Data Port:

  • Connectivity: RJ45, auto-crossover.
  • Wire type: 4-pair CAT5e and higher.
  • Speed: 10/100/1000 Mbps.
  • Distance: up to 100m.

Environmental:

  • Refer to Environmental Conditions on page 5.

LED Indicators (Refer to Fig. 4, Pg. 4):

  • Yellow and Green LEDs (RJ45 jacks):
    Yellow (left) LED: 10/100 Mbps.
    Green (right) LED: 1000 Mbps.

  • Green PoE LEDs: Indicate PoE present.

  • Green SFP (Fiber) LED: Indicates SFP connection.

Mechanical:
NetWaySP1BT:

  • Modular plastic case. 3.375” x 3.8” x 1” (85.7mm x 96.5mm x 25.4mm).

NetWaySP1BTWPN:

  • NEMA4/4X, IP66 Rated enclosure for outdoor use.
  • Dimensions (H x W x D approx.): 9.5” x 7.32” x 4.92” (241.3mm x 185.9mm x 125mm)

Recommended Altronix Power Sourcing Equipment:

NetWaySP4P
Ethernet to Fiber Media Converter with Integral Power Supply/Charger. Four (4) 56VDC non power-limited outputs up to 120W max. full power per port (240W total power). Four (4) 1Gb SFP ports.
NetWaySP4PX
Ethernet to Fiber Media Converter with Integral Power Supply/Charger. Four (4) 56VDC non-power-limited outputs up to 120W max. full power per port (480W total power). Four (4) 1Gb SFP ports.
NetWaySP4P2
Ethernet to Fiber Media Converter with Integral Power-Limited Power Supply/Charger. Four (4) 56VDC power-limited outputs up to 60W max. full power per port (240W total power). Four (4) 1Gb SFP ports.
WayPoint562
High Current Outdoor Power Supply/Charger. 56VDC/120W output. Filtered and electronically regulated output. Short circuit and thermal overload protection.
Vertiline563
EIA 19″ 1U Rack Mountable Dual Independent Power Supply/Charger. 56VDC @ 3A each output. Filtered and electronically regulated output. Short circuit and thermal overload protection.
PoE201
Power Supply/Charger Board. 56VDC/120W output. Filtered and electronically regulated output. Short circuit and thermal overload protection.

Recommended Altronix SFP Modules:

Altronix P1MM, P1SM10, P1AB2K and P1GCE are hot-pluggable SFP fiber transceiver modules and are readily usable with all Altronix Spectrum fiber optic equipment for 1Gb transmission rates.
P1MM …………………….For use with Multi-Mode Fiber for distances up to 550m.
P1SM10………………...For use with Single-Mode Fiber for distances up to 10km.
P1AB2K………………….. For use with Single Strand Single-Mode Fiber for distances up to 2km.
P1GCE …………………………For use with CAT5e or better for distances up to 100m.

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. All units should be installed by trained service personnel.
Installation:
NetWaySP1BT:

  1. Mount NetWaySP1BT in the desired location utilizing the mounting hole (Fig. 1a, pg. 4). Use a proper fastener and/or wall anchor when securing NetWaySP1BT with a screw through its mounting hole to the surface.
    Note: Earth ground can be used, if needed, for high transient or outdoor environments. If used, insert an Earth ground wire (included with product) into the internal ground terminal until secured (a slight tug can check stability) & fasten the free end to a chassis earth ground. If earth ground is not attached and needed, refer to Fig. 3, pg. 5 for manual placement.
    NetWaySP1BTWPN:

  2. Remove the backplane from the enclosure prior to drilling. Do not discard hardware.
    Note: Make sure that hardware will not interfere with the components of the circuit board.

  3. Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings to be used are 0.5″. Follow the manufacturer’s specifications for the appropriate size opening.
    Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. To facilitate wire entry utilize weather-tight NEMA-rated connectors (supplied), bushings, and cable.

  4. Clean out the inside of the enclosure before remounting circuit boards/backplanes.

  5. Mounting NEMA4/4X rated enclosure (Enclosure Dimensions, pg. 7):
    Wall mount: Mount the unit in the desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure enclosure with appropriate fasteners (e. g. screws and anchors; bolts and locking nuts, etc.) that are compatible with the mounting surface and are of sufficient length/construction to ensure a secure mount (Fig. 5, pg. 7).
    Pole Mount : Refer to Fig. 6 – 10, pg. 7.

  6. Mount the backplane in an enclosure with hardware.

Power Connection:

  1. Use the external 48-55V UL Listed ITE power supply, carefully observing the correct polarity (Fig. 1, 2, pg. 4).
  2. Use 14AWG or larger for all power connections.
    Keep power-limited wiring separate from non-power-limited wiring by utilizing separate knockouts/ inlets. Minimum 0.25″ spacing must be provided.
    CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user-serviceable parts inside. Refer installation and servicing to qualified service personnel.

Input/Data Connections:

  1. Connect the structured cable from the port marked [Data Port] on NetWaySP1BT to a PoE midspan/endspan (Fig. 3, pg. 5).
  2. Connect fiber optic cable to a fiber SFP module. Connect the module to the port marked [SFP] on the NetWaySP1BT. Connect the other end of the fiber cable to an SFP module of a remote device. SFP LED will illuminate indicating data connection (Fig. 3, pg. 5).
  3. Using a 4-pair CAT5e or higher cable connect the PoE load device to be powered to the port marked [802.3bt Output] on NetWaySP1BT. After authentication and classification have been established, [PoE Signal] LED will illuminate indicating PoE presence.

Typical Application:

Technical Specifications:

Parameter Description
Ports One (1) 1Gb SFP port, one (1) Data port.

One (1) IEEE 802.3af, 802.3at and 802.3bt compliant output port rated up to 90W max.
Input Power Requirements| 48-56VDC © 1.9A (95W).
See pg. 3 for recommended Power Sourcing Equipment.
Indicators| Yellow and Green LEDs (RJ45 jacks): IP Link status, 10/100/1000 Base-T/active.
PoE Green LED: Indicates PoE present.
Fiber Signal Green LED: Indicates SFP connection.
Environmental Conditions| Temperature: NetWaySP1 BT:
Operating (90W): – 40°C to 75°C (— 40°F to 167°F).
Storage: – 40°C to 75°C (— 40°F to 167°F).
NetWaySP1 BTWPN:
Operating:
60W: – 40°C to 75°C (— 40°F to 167°F).
80W: – 40°C to 70°C (— 40°F to 158°F).
90W: – 40°C to 60°C (— 40°F to 140°F).
Storage: – 40°C to 85°C (— 40°F to 185°F).
Relative Humidity: 85% +/-5%.
Operating Altitude: — 304.8 to 2,000m.
Regulatory Compliance| ****CE European Conformity.
Weights (approx.)| NetWaySP1BT: Product: 0.25 lb. (0.11 kg) I Shipping: 0.3 lb. (0.14 kg).
NetWaySP1BTWPN: Product: 3.7 lb. (1.68 kg) I Shipping: 5 lb. (2.27 kg).

Wall Mount Installation:

1- Place the unit at the desired location and secure it with mounting screws (not included) (Fig. 5, pg. 7). Fig. 5
Pole Mounting Using Optional Pole Mount Kit PMK1:
This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK outdoor pole mount kit is designed to simplify the installation of Altronix outdoor-rated power supplies and accessories housed in models WP1, WP3, and WP4 NEMA-rated enclosures. PMK1 can be mounted on 2″ to 8″ (50.8mm to 203.2mm) diameter round or 5″ (127mm) square poles. Brackets are designed for use with the Wormgear Quick Release Straps (two included).

  1. Thread one (1) wormgear quick-release strap through the slots on the back of a mounting bracket (Fig. 5, pg. 7).

  2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding the open end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16″ hex socket driver (Fig. 7, pg. 7 and Fig. 9, pg. 7).

  3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16″ hex socket (Fig. 8, pg. 7).

  4. Thread the second wormgear quick-release strap through the slots on the back of the bottom mounting bracket (Fig. 9, pg. 7).

  5. Mount the enclosure onto the top bracket by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16″ hex socket (Fig. 7, pg. 7).

  6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten the screw with a flathead screwdriver or 5/16″ hex socket driver (Fig. 7, pg. 7).

  7. Clip excess straps.

NetWaySP1BTWPN
Mechanical Drawing and Dimensions
(H x W x D approx.):

9.5″ x 7.32″ x 4.92″ (241.3mm x 185.9mm x 125mm)

Altronix is not responsible for any typographical errors.­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA
phone: 718-567-8181
fax: 718-567-9056
website: www.altronix.com 
e-mail: info@altronix.com 
Lifetime WarrantyNetWaySP1BT Series

Installation Guide

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals