V-TAC VT-81011 Ceiling Mounted Infrared PIR Sensor Instruction Manual

June 1, 2024
V TAC

V-TAC-LOGOV-TAC VT-81011 Ceiling Mounted Infrared PIR Sensor

V-TAC-VT-81011-Ceiling-Mounted-Infrared-PIR-Sensor-
PRODCUT

Specifications

  • Model: VT-81011
  • SKU: 23427
  • Input Voltage: AC: 220-240V, 50/60 Hz
  • Rated Load: Max. 800W
  • Time Delay: Adjustable
  • Detection Range: Up to 8m
  • Detection Distance: Varies based on installation
  • Detection Motion Speed: Standard
  • Working Temperature: Suitable for indoor use
  • Working Humidity: Standard humidity levels
  • Power Consumption: Varies based on usage
  • IP Rating: Weatherproof design (specify rating if available)

TECHNICAL DATA

MODEL VT-81011
SKU 23427
INPUT VOLTAGE AC: 220-240V, 50/60 Hz
RATED LOAD Max. 800W

400W     +LED

TIME DELAY| Min. 10sec ±3sec Max. 15min ±2min
DETECTION RANGE| 360°
DETECTION DISTANCE| 8m Max (<24° C)
DETECTION MOTION SPEED| 0.6-1.5m/s
WORKING TEMPERATURE| -20°C to +40°C
|
WORKING HUMIDITY| <93%RH
POWER CONSUMPTION| Approx, 0.9W
IP RATING| IP20


AMBIENT LIGHT

| ****

<3-2000 LUX (Adjustable)

---|---
INSTALLATION HEIGHT| 2.2-4m
DIMENSION| Ø102×24.9 mm

INTRODUCTION & WARRANTY

Thank you for selecting and buying the V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any other queries, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at your best. The warranty is valid for 5 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product.

Caution, risk of electric shock.

MULTI-LANGUAGE MANUAL QR CODE Please scan the QR code to access the manual in multiple languages.

V-TAC-VT-81011-Ceiling-Mounted-Infrared-PIR-Sensor-
FIG-1

This marking indicates that this product should not be disposed of with other household wastes.

Points de collecte sur www.quefairedemesdechets.fr

In case of any query/issue with the product, please reach out to us at: support@v-tac.eu For More product ranges, inquiry please contact our distributor or nearest dealers.
V-TAC EUROPE LTD. Bulgaria, Plovdiv 4000, bul.L.Karavelow 9B

WARNING

  1. Please make sure to turn off the power before starting the installation.
  2. Installation must be performed by a qualified electrician.
  3. Cover or shy any adjacent live components.
  4. For indoor use only.

FUNCTION

  1. Can identify day and night: The consumer can adjust the working state in different ambient light. It can work in the daytime and at night when it is adjusted to the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted to the “3” position (min). As for the adjustment pattern, please refer to the testing pattern.
  2. Time-Delay is added continually: When it receives the second induction signal within the first induction, it will restart to time from the moment.V-TAC-VT-81011-Ceiling-Mounted-Infrared-PIR-Sensor-FIG-3

INSTALLATION ADVICE

As the detector responds to changes in temperature, avoid the following situations:

  • Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
  • Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
  • Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.

V-TAC-VT-81011-Ceiling-Mounted-Infrared-PIR-Sensor-
FIG-4

INSTALLATION

  • Please move the upper cover with an anti-clockwise whirl as per the diagram on the right.
  • Connect the power and the load according to the connection-wire diagram.
  • Fix the bottom on the selected position with the inflated screw.
  • Install back the upper cover on the sensor, then you could switch on the power and test it.

WIRING DIAGRAM

V-TAC-VT-81011-Ceiling-Mounted-Infrared-PIR-Sensor-
FIG-6

SENSOR INFORMATION

V-TAC-VT-81011-Ceiling-Mounted-Infrared-PIR-Sensor-
FIG-7

TEST

  • Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob clockwise on the maximum (sun).

  • Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work.If the sensor receives the induction signal, the lamp will turn on.
    While there is no other induction signal anymore, the load should stop working within 10sec±3sec and the lamp would turn off.

  • Turn the LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the sensor will not work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor will work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.

Note : when testing in daylight, please turn the LUX knob to ☼ the (SUN) position, Otherwise the sensor lamp will not work. If the lamp is more than 60W, the distance between the lamp and the sensor should be 60cm at least.

TROUBLESHOOTING

The load does not work

  • a. Please check if the connection of the power source and load is correct.
  • b. Please check if the load is good.
  • c. Please check if the settings of the working light correspond to ambient light.

The sensitivity is poor:

  • a. Please check if there is any hindrance in front of the detector to affect it to receive the signals.
  • b. Please check if the ambient temperature is too high.
  • c. Please check if the induction signal source is in the detection field.
  • d. Please check if the installation height corresponds to the height required in the instructions.
  • e. Please check if the moving orientation is correct.

The sensor can not shut off the load automatically:

  • a. Please check if there is a continual signal in the detection field.
  • b. Please check if the time delay is set to the maximum position.

Frequently Asked Questions

  • Q: What should I do if the sensor is not detecting motion?
    • A: Check the power supply, adjust the detection range, and ensure no obstacles are blocking the sensor’s view.
  • Q: Can the sensor be used outdoors?
    • A: The sensor is designed for indoor use, but some models may have weatherproof features suitable for outdoor use. Refer to the product specifications for more details.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals