Miele DAD4840 GB Black Levantar Downdraft Extractor System Instruction Manual
- June 1, 2024
- Miele
Table of Contents
DAD 4840 Black Levantar
Downdraft extractor system
in elegant matt black design and with intuitive SmartControl operation
- 916 mm wide – the perfect combination with panorama hobs
- Easy recirculation mode installation with plug&play accessory set
- Motorised retractable deflector plate – Hood in Motion
- Unique user convenience – Con@ctivity
- Efficient filtration- 10-ply stainlesssteel grease filter
EAN: 4002516538981 / Material number: 11875820 / Old Material Number: 28D4840MGB
Construction type|
---|---
Downdraft extractor system| •
Operating modes|
Type of air guide| Can be retrofitted
Recirculation conversion kit (order separately)| DUU 600
Active charcoal filter (order separately)| DKF 30-P, DKF 30-R
Design|
Colour| Black
Edge extraction| •
User convenience|
Miele@home| •
Automatic function Con@ctivity| •
Electronic controls| •
Touch-on-glass controls| •
Programmable Booster level switch-off| •
Run-on time 5/15 min.| •
Grease filter saturation indicator| •
Grease filter saturation indicator programmable| •
Active charcoal filter saturation indicator programmable| •
Motor-operated cooker hoods| •
Easy-to-clean canopy interior – CleanCover| •
Efficiency and sustainability|
Energy efficiency class (A+++ – D)| A
ECO motor| •
PowerManagement system| •
Annual energy consumption in kWh/year| 41.6
Fluid dynamic efficiency class| A
Lighting efficiency class| A
Grease filtering efficiency class| B
Filter system|
Number of dishwasher-safe stainless steel grease filters (10-ply)| 2
Lighting|
LED| •
Number x W| 1 x 11,2 W
Light intensity in Lx| 400 lx
Colour temperature in K| 3500 Kelvin
Dimmer function| •
Fan|
Dual-action fan| •
DC motor| •
Exhaust air|
Air throughput in Level 1 (m³/h) according to EN 61591| 200
Air throughput in Level 2 (m³/h) according to EN 61591| 340
Air throughput in Level 3 (m³/h) according to EN 61591| 440
Air throughput in Booster level (m³/h) according to EN 61591| 600
Air throughput in booster level 2 (m³/h)| 640
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3| 44.0
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3| 57.0
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3| 62.0
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3| 70.0
Sound power in Booster level 2 (dB(A) re 1 pW) acc. to EN 60704-3| 72.0
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13| 30.0
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13| 43.0
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13| 49.0
Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13| 56.0
Sound pressure in Booster level 2 (dB(A) re 20 µPa) acc. to EN 60704-2-13|
58.0
Recirculation|
Air throughput in Level 1 (m³/h) according to EN 61591| 160
Air throughput in Level 2 (m³/h) according to EN 61591| 320
Air throughput in Level 3 (m³/h) according to EN 61591| 415
Air throughput in Booster level 1 (m³/h) according to EN 61591| 520
Air throughput in Booster level 2 (m³/h) according to EN 61591| 555
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3| 50.0
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3| 64.0
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3| 69.0
Sound power in Booster level 1 (dB(A) re 1 pW) acc. to EN 60704-3| 75.0
Sound power in Booster level 2 (dB(A) re 1 pW) acc. to EN 60704-3| 76.0
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13| 37.0
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13| 50.0
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13| 56.0
Sound pressure in Booster level 1 (dB(A) re 20 µPa) acc. to EN 60704-2-13|
61.0
Sound pressure in Booster level 2 (dB(A) re 20 µPa) acc. to EN 60704-2-13|
62.0
Safety|
Safety switch-off| •
Single-ply safety glass (ESG)| •
Technical data|
Canopy width in mm| 916
Canopy depth in mm| 170
Net weight in kg| 34.0
Length of supply lead in m| 1.5
Standard plug fitted| •
Total rated load in kW| 0.25
Voltage in V| 230
Fuse rating in A| 10
Number of phases| 1
Frequency in Hz| 50
Installation notes|
Diameter of exhaust duct in mm| 150
Optimal combination with hob| KM 7684 FL; KM 7689 FL
Combination with WiFi-enabled Miele hob| recommended
Optional accessories|
Active charcoal filter| Nein
more information you can find here:
http://www.miele.ie
DAD4840, Installation drawings
1. Stepped cutout for flush-fit installation in stone worktops (granite, marble)., 2. Ensure that materials are sufficiently stable., 3. Cut-out off- centre., Exhaust duct Ø 150 mm., * Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used.
DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings
DAD4840, DAD4940 – DUU600 Plinth box, Installation version 2, Installation drawings
DAD4840, DAD4940, overlying – AP600 mm, Side view, Installation drawings
Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., Exhaust duct Ø 150 mm.
DAD484x, DAD494x, flush – AP600 mm, Top view, Installation drawings
Exhaust duct Ø 150 mm.
DAD4840, DAD4940, overlying AP > 600 mm, Side view, Installation drawings
Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., Exhaust duct Ø 150 mm.
DAD4840, DAD4940, flush AP > 600 mm, Side view, Installation drawings
Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., Exhaust duct Ø 150 mm.
DAD484x, DAD494x, flush AP > 600 mm, Top view, Installation drawings
Exhaust duct Ø 150 mm.
DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings
DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings
DUP 150
DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings
DUP 150
DAD4840, DAD4940 – DUU 600 Plinth box, Installation version 2, Installation drawings
DFK-AK 90, DFK-R 1000, DFK-BH-45, DUU 600
DAD4840, DAD4940 – DMK150-1 wall box, Installation version 3, Installation drawings
DFK-AK 90, DFK-R 1000, DFK-BH 45, DFK-A, DMK 150-1
DAD4840, DAD4940 – surface mounted – side view – Installation drawings
Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.
DAD4840, DAD4940 – flush – side view – Installation drawings
Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.
DAD4840, DAD4940, DAD4841, DAD4941 – surface mounted, AP > 600 mm – side view – Installation drawings
Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.
DAD4840, DAD4940, DAD4841, DAD4941 – flush – side view – Installation drawings
Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.
DAD4840, DAD4940, DAD4841, DAD4941 – surface mounted, AP > 600 mm – side view – Installation drawings
Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.
DAD4840, DAD4940, DAD4841, DAD4941 – flush – side view – Installation drawings
Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.
DAD4840, DAD4940, overlying, Installation drawings
- Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop.
DAD4840, DAD4940, flush, Installation drawings
- Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. , Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.
DAD4840, DAD4940, overlying, Installation drawings
- Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop.
DAD4840, DAD4940, flush, Installation drawings
- Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. Instead of a, Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be, can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.
DAD4840, DAD4940, Installation drawings
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>