Miele DAD4840 GB Black Levantar Downdraft Extractor System Instruction Manual

June 1, 2024
Miele

Miele logo2

DAD 4840 Black Levantar

Downdraft extractor system

in elegant matt black design and with intuitive SmartControl operation

  • 916 mm wide – the perfect combination with panorama hobs
  • Easy recirculation mode installation with plug&play accessory set
  • Motorised retractable deflector plate – Hood in Motion
  • Unique user convenience – Con@ctivity
  • Efficient filtration- 10-ply stainlesssteel grease filter

EAN: 4002516538981 / Material number: 11875820 / Old Material Number: 28D4840MGB

Construction type|
---|---
Downdraft extractor system| •
Operating modes|
Type of air guide| Can be retrofitted
Recirculation conversion kit (order separately)| DUU 600
Active charcoal filter (order separately)| DKF 30-P, DKF 30-R
Design|
Colour| Black
Edge extraction| •
User convenience|
Miele@home| •
Automatic function Con@ctivity| •
Electronic controls| •
Touch-on-glass controls| •
Programmable Booster level switch-off| •
Run-on time 5/15 min.| •
Grease filter saturation indicator| •
Grease filter saturation indicator programmable| •
Active charcoal filter saturation indicator programmable| •
Motor-operated cooker hoods| •
Easy-to-clean canopy interior – CleanCover| •
Efficiency and sustainability|
Energy efficiency class (A+++ – D)| A
ECO motor| •
PowerManagement system| •
Annual energy consumption in kWh/year| 41.6
Fluid dynamic efficiency class| A
Lighting efficiency class| A
Grease filtering efficiency class| B
Filter system|
Number of dishwasher-safe stainless steel grease filters (10-ply)| 2
Lighting|
LED| •
Number x W| 1 x 11,2 W
Light intensity in Lx| 400 lx
Colour temperature in K| 3500 Kelvin
Dimmer function| •
Fan|
Dual-action fan| •
DC motor| •
Exhaust air|
Air throughput in Level 1 (m³/h) according to EN 61591| 200
Air throughput in Level 2 (m³/h) according to EN 61591| 340
Air throughput in Level 3 (m³/h) according to EN 61591| 440
Air throughput in Booster level (m³/h) according to EN 61591| 600
Air throughput in booster level 2 (m³/h)| 640
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3| 44.0
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3| 57.0
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3| 62.0
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3| 70.0
Sound power in Booster level 2 (dB(A) re 1 pW) acc. to EN 60704-3| 72.0
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13| 30.0
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13| 43.0
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13| 49.0
Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13| 56.0
Sound pressure in Booster level 2 (dB(A) re 20 µPa) acc. to EN 60704-2-13| 58.0
Recirculation|
Air throughput in Level 1 (m³/h) according to EN 61591| 160
Air throughput in Level 2 (m³/h) according to EN 61591| 320
Air throughput in Level 3 (m³/h) according to EN 61591| 415
Air throughput in Booster level 1 (m³/h) according to EN 61591| 520
Air throughput in Booster level 2 (m³/h) according to EN 61591| 555
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3| 50.0
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3| 64.0
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3| 69.0
Sound power in Booster level 1 (dB(A) re 1 pW) acc. to EN 60704-3| 75.0
Sound power in Booster level 2 (dB(A) re 1 pW) acc. to EN 60704-3| 76.0
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13| 37.0
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13| 50.0
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13| 56.0
Sound pressure in Booster level 1 (dB(A) re 20 µPa) acc. to EN 60704-2-13| 61.0
Sound pressure in Booster level 2 (dB(A) re 20 µPa) acc. to EN 60704-2-13| 62.0
Safety|
Safety switch-off| •
Single-ply safety glass (ESG)| •
Technical data|
Canopy width in mm| 916
Canopy depth in mm| 170
Net weight in kg| 34.0
Length of supply lead in m| 1.5
Standard plug fitted| •
Total rated load in kW| 0.25
Voltage in V| 230
Fuse rating in A| 10
Number of phases| 1
Frequency in Hz| 50
Installation notes|
Diameter of exhaust duct in mm| 150
Optimal combination with hob| KM 7684 FL; KM 7689 FL
Combination with WiFi-enabled Miele hob| recommended
Optional accessories|
Active charcoal filter| Nein

more information you can find here:
http://www.miele.ie

DAD4840, Installation drawings

1. Stepped cutout for flush-fit installation in stone worktops (granite, marble)., 2. Ensure that materials are sufficiently stable., 3. Cut-out off- centre., Exhaust duct Ø 150 mm., * Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used.

DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings

DAD4840, DAD4940 – DUU600 Plinth box, Installation version 2, Installation drawings

DAD4840, DAD4940, overlying – AP600 mm, Side view, Installation drawings

Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., Exhaust duct Ø 150 mm.

DAD484x, DAD494x, flush – AP600 mm, Top view, Installation drawings

Exhaust duct Ø 150 mm.

DAD4840, DAD4940, overlying AP > 600 mm, Side view, Installation drawings

Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., Exhaust duct Ø 150 mm.

DAD4840, DAD4940, flush AP > 600 mm, Side view, Installation drawings

Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., Exhaust duct Ø 150 mm.

DAD484x, DAD494x, flush AP > 600 mm, Top view, Installation drawings

Exhaust duct Ø 150 mm.

DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings

DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings

DUP 150

DAD4840, DAD4940 – DUP150, Installation version 1, Installation drawings

DUP 150

DAD4840, DAD4940 – DUU 600 Plinth box, Installation version 2, Installation drawings

DFK-AK 90, DFK-R 1000, DFK-BH-45, DUU 600

DAD4840, DAD4940 – DMK150-1 wall box, Installation version 3, Installation drawings

DFK-AK 90, DFK-R 1000, DFK-BH 45, DFK-A, DMK 150-1

DAD4840, DAD4940 – surface mounted – side view – Installation drawings

Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.

DAD4840, DAD4940 – flush – side view – Installation drawings

Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.

DAD4840, DAD4940, DAD4841, DAD4941 – surface mounted, AP > 600 mm – side view – Installation drawings

Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.

DAD4840, DAD4940, DAD4841, DAD4941 – flush – side view – Installation drawings

Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.

DAD4840, DAD4940, DAD4841, DAD4941 – surface mounted, AP > 600 mm – side view – Installation drawings

Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.

DAD4840, DAD4940, DAD4841, DAD4941 – flush – side view – Installation drawings

Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., Exhaust air connection Ø 150 millimetres.

DAD4840, DAD4940, overlying, Installation drawings

  1. Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop.

DAD4840, DAD4940, flush, Installation drawings

  1. Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. , Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.

DAD4840, DAD4940, overlying, Installation drawings

  1. Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop.

DAD4840, DAD4940, flush, Installation drawings

  1. Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. Instead of a, Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be, can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.

DAD4840, DAD4940, Installation drawings

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals