Infratech CD-Series 61-1 4 Inch Dual Element 6000W 240V Electric Patio Heater User Manual
- June 17, 2024
- INFRATECH
Table of Contents
Infratech CD-Series 61-1 4 Inch Dual Element 6000W 240V Electric Patio
Heater
Product Information
Specifications
- Model: ALL WEATHER C-SERIES and CD-SERIES
- Type: Quartz Tube Electric Infrared Radiant Heater
- Country of Origin: USA
Warnings
- Read all instructions before using the heater.
- The unit may be a source of possible shock. Never attempt to service the heater without disconnecting its power source.
- Source of possible ignition.
Installation Instructions
- Ensure proper outdoor wiring.
- Use only wiring components UL/CUL/CE listed for outdoor use with IPX4 minimum rating.
- The heater is drilled and threaded for standard 1/2 conduit fittings. The installing electrician will need to provide the appropriate rigid metallic, flexible, or liquid-tight conduit for the installation location.
- Connect power with a flexible conduit or appropriate cord to allow the heater to be swiveled.
Wiring Instructions
- The wiring options depend on the voltage
- For a Single Pole Switch (120V)
- For a Two Pole Switch (240V)
- For Optional 120V/240V Controls
Mounting Instructions
These models may be chain or bracket-mounted to any ceiling or horizontal surface.
The installation must maintain the following clearances:
- Minimum 18″ (45.7cm) clearance on all four sides of the heater.
- Minimum 36″ (91.4cm) clearance directly in front of the heater.
- A minimum 6″ (15.24cm) clearance is provided by mounting brackets behind the plane of the face.
- The heater can be hung using chains or custom brackets.
- It must be level but can be rotated around its horizontal axis.
Heater Leveling
- The heater must be installed with the quartz tube horizontally level.
- For maximum tube life, use a carpenter’s level tool to find the optimum level position for the heater’s body.
- Always maintain the minimum clearances from the heater body to any combustible materials.
Maintenance Instructions
- Refer to the maintenance instructions provided in the user manual for detailed maintenance procedures.
Troubleshooting
- Refer to the troubleshooting section in the user manual for assistance with common issues and solutions.
Location Suggestions
- Follow the location suggestions provided in the user manual for optimal installation and performance of the heater.
Warranty
- Refer to the warranty section in the user manual for information regarding the product’s warranty.
FAQ
Q: Can the heater be used indoors?
- A: No, this heater is designed for outdoor use only.
Q: What is the recommended mounting height?
- A: The recommended mounting height is not specified in the user manual. However, it is important to ensure the minimum clearances are maintained as mentioned in the mounting instructions.
Q: Can the heater be used with a dimmer switch?
- A: No, this heater is not compatible with dimmer switches. It should only be used with the specified wiring options mentioned in the user manual.
WARNINGS
- READ ALL INSTRUCTIONS BEFORE USING HEATER. The unit may be a source of possible shock.
- NEVER attempt to service the heater without disconnecting its power source. Source of possible ignition.
- WARNING: If not installed, operated, and maintained under the manufacturer’s instructions, this product can expose you to chemicals including nickel, which are known to the State of California to cause cancer.
- For more information go to www.P65Warnings.ca.gov.
CAUTION
- High Temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at least 3′ (0.9m) from the front of the heater and away from sides and rear.
MOUNTING HEIGHT/CLEARANCES
CLEARANCE FROM COMBUSTIBLES:
- For Wall-Mounting, do not install a heater closer than 18″ (45.7cm) from adjacent walls and 12″ (30.5cm) from the ceiling, and do not install less than 6′ (1.8m) if the heater is labeled as UL Listed and 8′ (2.4m) if the heater is labeled as UL/CUL Listed from floor, while heater is set at a downward angle of 30 to 60 degrees.
- For ceiling mounting, do not install a heater closer than 18″ (45.7cm) from adjacent walls and 6″ (15.2cm) from the ceiling, and do not install less than 6′ (1.8m) if the heater is labeled as UL Listed and 8′ (2.4m) if the heater is labeled as UL/CUL Listed from the floor, while the heater is at a maximum 30 degrees.
- Adjacent Heaters are to be installed no less than 3′ (0.9m) apart.
- Do NOT operate within 25′ (7.6m) of flammable/explosive material.
- Never block the heater.
- Heaters greater than 240 Volts are for “Commercial Use Only. Risk of fire. Do not use it as a residential or household heater.
- A means for disconnection of the appliance must be incorporated under the local wiring codes.
- Do not use it if the heating element is damaged or cracked.
- Not for use as a replacement for forced air/ductless heating.
- Do not leave powered heaters unattended.
INSTALLATION INSTRUCTIONS
- This heater must be permanently installed and hard-wired by a licensed electrician under local electrical codes.
- Assembly procedure must be performed with no electrical power to the unit.
- Step 1: Check the UL/CUL/CE label on a heater for proper voltage.
- Step 2: Follow the supplied wiring instructions. (See wiring instructions below)
- Step 3: The heater must be mounted with a reflector angled down.
- Step 4: All electrical connections must comply with the National Electric Code (NEC) and local codes for outdoor wiring.
- Step 5: Use only wiring components UL/CUL/CE listed for outdoor use with IPX4 minimum rating.
WIRING INSTRUCTIONS
- The heater is drilled and threaded for standard 1/2″ conduit fittings.
- The installing electrician will need to provide the appropriate rigid metallic, flexible, or liquid-tight conduit for the installation location.
- Observe local electrical code regulations.
- Remove the cover plate from a junction box.
- Attach conduit.
- Use only copper wire suitable for 90°C.
- Replace the cover plate.
MOUNTING INSTRUCTIONS
- These models may be chain or bracket mounted to any ceiling or horizontal surface.
- Installation must be such that 18″ (45.7cm) minimum clearance is maintained around the heater on all four sides and 36″ (91.4cm) directly in front.
- A minimum of 6″ (15.24cm) of clearance provided by mounting brackets is required behind the plane of the face.
- The heater can be hung using chains or custom brackets.
- The heater must be level but can be rotated around its horizontal axis.
- The heater must be installed with the quartz tube horizontally level. For maximum tube life, use a carpenter’s level tool to find the optimum level position for the heater’s body.
- It’s important to always maintain the minimum clearances from the heater body to any combustible materials.
REPLACEMENT ELEMENT INSTALLATION (VISIT INFRATECH-USA.COM FOR VIDEO INSTRUCTIONS)
- Disconnect the power at the breaker. Remove the grill by grasping it in the middle, flex the grill up, and lift it off.
- Unscrew and remove both end reflectors.
- Unhook element clips at each end of the heater and remove nuts from the end of the element to remove the existing quartz tube.
- Carefully install the new element.
- Remove one nut from the end of the new element. Install wire by sliding the high-temperature ring terminal onto the element screw and replace the nut.
- Use a thin 11/32″ wrench to hold the inside nut. Nuts must make a tight connection.
- Close element clips over the tube, reinstall end reflectors, and then snap the protective grill back in place.
- NOTE: Hold ceramic element firmly while tightening the nut to prevent damage to the element. The nut should be tightened snugly. A loose connection can cause the element to short or fail prematurely.
REPLACEMENT ELEMENTS (OTHER VOLTAGES ALSO AVAILABLE)
PART NUMBER| ELEMENT NUMBER| LENGTH| WATTS| VOLTS|
FITS
---|---|---|---|---|---
10-1020| E-7512| 16-1/2″ (0.4m)| 750| 120| C-7512
10-1050| E-1412| 30″ (0.8m)| 1500| 120| C-1512
10-1055| E-1424| 30″ (0.8m)| 1500| 240| C-1524/CD-3024
10-1085| E-2024| 36″ (0.9m)| 2000| 240| C-2024/CD-4024
10-2010| E-2524| 36″ (0.9m)| 2500| 240| C-2524/CD-5024
10-2030| E-3024| 58″ (1.5m)| 3000| 240| C-3024/CD-6024
10-2055| E-4024| 58″ (1.5m)| 4000| 240| C-4024
- Consult the label on the back of the heater for proper watts, voltage, and replacement element part number.
- Need help? To order replacement elements for your Infratech heating system, please contact us via phone or visit our website.
REPLACEMENT PARTS
PART NUMBER | PART DESCRIPTION | QUANTITY |
---|---|---|
13-1210 | Single Element End Reflector (Set of 2) | 1 |
13-1252 | Dual Element End Reflector (Set of 2) | 1 |
13-1207, 13-1208, 13-1209 | C-Series Body Reflector – Fits 33″ (0.8m), 39″ | |
(1.0m), 61-1/4″ (1.6m) | 1 | |
13-1242, 13-1240, 13-1245 | Grill Guard – Fits 33″ (0.8m), 39″ (1.0m), 61-1/4″ | |
(1.6m) | 1 | |
13-1232, 13-1230, 13-1235 | Lead Wire Set – Fits 33″ (0.8m), 39″ (1.0m), | |
61-1/4″ (1.6m)* | 1 | |
13-1250 | SS Mounting Bracket (Set of 2) | 1 |
Note: Dual Element Heaters require 2 Lead Wire Sets per Heater
SINGLE ELEMENT AREAS COVERED (FEET)
MODEL| WATTS| MOUNTING HEIGHT| AVERAGE| COLD|
PROTECTED
---|---|---|---|---|---
C-1512 SS| 1,500| 6′ – 7′ (1.8m – 2.4m)| 5′ x 5′ (1.5m x 1.5m)| 3′ x
3′ (0.91m x 0.91m)| 7′ x 7′ (2.1m x 2.1m)
C-2024 SS| 2,000| 7′ – 8′ (2.1m – 2.7m)| 6′ x 6′ (1.8m x 1.8m)| 4′ x
4′ (1.2m x 1.2m)| 8′ x 8′ (2.4m x 2.4m)
C-2524 SS| 2,500| 7′ – 8′ (2.1m – 2.7m)| 7′ x 7′ (2.1m x 2.1m)| 5′ x
5′ (1.5m x 1.5m)| 9′ x 9′ (2.7m x 2.7m)
C-3024 SS| 3,000| 7′ – 9′ (2.1m – 2.7m)| 8′ x 8′ (2.4m x 2.4m)| 6′ x
6′ (1.8m x 1.8m)| 10′ x 10′ (3.0m x 3.0m)
C-4024 SS| 4,000| 8′ – 10′ (2.4m – 3.4m)| 10′ x 10′ (3.0m x 3.0m)|
8′ x 8′ (2.4m x 2.4m)| 12′ x 12′ (3.7m x 3.7m)
Also available in 316 Marine Grade Stainless Steel on request
DUAL ELEMENT AREAS COVERED (FEET)
MODEL | WATTS | MOUNTING HEIGHT | AVERAGE | COLD | PROTECTED |
---|---|---|---|---|---|
CD-3024 SS | 3,000 | 7′ – 8′ (2.1m x 2.7m) | 7′ x 7′ (2.1m x 2.1m) | 5′ | |
x 5′ (1.5m x 1.5m) | 9′ x 9′ (2.7m x 2.7m) | ||||
CD-4024 SS | 4,000 | 8′ – 10′ (2.4m – 3.7m) | 8′ x 10′ (2.4m x 3.0m) | ||
6′ x 8′ (1.8m x 2.4m) | 10′ x 12′ (3.0m x 3.7m) | ||||
CD-5024 SS | 5,000 | 8′ – 10′ (2.4m – 3.7m) | 9′ x 10′ (2.7m x 3.0m) | ||
7′ x 8′ (2.1m x 2.4m) | 11′ x 12′ (3.4m x 3.7m) | ||||
CD-6024 SS | 6,000 | 8′ – 12′ (3.0m – 4.3m) | 11′ x 11′ (3.4m x 3.4m) | ||
10′ x 10′ (3.0m x 3.0m) | 12′ x 12′ (3.7m x 3.7m) |
Also available in 316 Marine Grade Stainless Steel on request
- NOTE: Mounting height should not be less than 6′ (1.8m) if the heater is labeled as UL Listed and 8′ (2.4m) if the heater is labeled as CUL Listed.
- Indoor or well-protected environments will generally exceed the average.
- Heaters can provide less-than-average coverage in extremely cold/windy conditions.
GENERAL NOTES
- INFRATECH QUARTZ TUBE ELECTRIC HEATERS are furnished with multi-position wall/ceiling mount brackets.
- See sales literature and price list for a full listing of models, descriptions, amperages, and voltages. At times, especially when the mounting height might be quite low, an increased number of smaller heaters can help prevent overheating.
- Heaters up to 15 AMPS can be controlled with a simple INF Input Regulator. This low-cost controller, which is an infinite switch, gently pulses the heat on and off at regular intervals when not on full power.
- Dual Element Heaters can be wired with our Duplex/Stack Switch, which enables the ability to turn on and off each element independently, providing for half power/full power capabilities.
- For ideal comfort heat, the best solution is to heat from two sides rather than from just one side. However, there are times when this is not practical.
- Coverage areas are approximate dimensions and will vary depending on prevailing and personal comfort levels.
- Indoor or well-protected environments will generally exceed average (see charts). Heaters can provide less-than-average coverage in extremely cold/windy conditions.
MAINTENANCE INSTRUCTIONS
- Before performing any maintenance, the power must be disconnected and the heater cool to the touch.
- Heater housing, reflectors, and heating elements can be rinsed with a hose or wiped down with isopropyl alcohol, acetone, or glass cleaner.
- Use a clean, scratch-free rag or paper towel.
- Any oxidation, surface rust, or discoloration can be removed with a stainless steel cleaner or metal polish on the bare metal surface.
- Make sure all water, solvents, or cleaners are removed and the heater is dry before reconnecting the power.
TROUBLESHOOTING
LOCATION SUGGESTIONS
Unless heaters are installed over 12′ (3.7m) high, it is generally recommended that all radiant heaters be mounted on an angle to ensure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed.
RECOMMENDED POSITIONING
- Angle fixture 30º to 60º from horizontal face down. The best angle is approximately 45º.
INSTALLATION DIRECTION
- Install a fixture to heat the area from the “cold side” if possible.
- This helps compensate for increased body heat losses due to exposure.
- Warm floors reradiate heat.
- Warmer air rises from the floor.
- Some heat reflects from the floor. Mounting a heater directly over a table or other obstruction will block the energy, primarily heating the object.
- It is best to move the heater to the side, allowing complete body and floor coverage.
OUTDOORS
- When outdoors, hang the heater under the protective roof or weather cover whenever possible.
- Even though the heater is all-weather construction, it will last longer and look better if it is protected from rain and snow.
LIMITED PRODUCT WARRANTY
- Model #: ——————————-
- Serial #: ——————————–
- Date of Purchase: ———————
- Purchased From:- ———————
- Thank you very much for purchasing an INFRATECH Quartz Tube Electric Heater.
- We have designed this heater to provide you and your family with many years of great outdoor experiences. Please fill in the Model and Serial number as well as the date of purchase in the areas indicated above. Please save this information for future reference. To get the full and safe enjoyment of your electric heater please read your Owner’s Manual carefully and review the proper operating and safety instructions with any family members that may be using the heater.
Manufacturer Warranty:
- INFRATECH warrants that this electric heater is designed and manufactured to be free from defects in materials and workmanship for THREE YEARS from the original date of purchase.
- NOTE: Use of competitor controls or accessories with Infratech heaters may void the Infratech Warranty.
Extent of Warranty:
- This warranty extends to the selling dealers to the original purchaser at the original site of installation: This warranty becomes valid at the time of purchase and ends either by the specified time frame listed above, owner transfer, or relocation.
- To activate the warranty we require that you send in the attached warranty registration form. This registration is for our internal use only and will only be used in the event we need to send you important safety-related product information.
- The information will not be sold or used for any marketing-related purposes.
Warranty Limitations and Exclusions:
- This warranty does not apply to damages resulting from negligence, alteration, misuse, abuse, accident, natural disaster, improper installation or improper operation, unauthorized adjustments or calibrations, dings, dents, scratches, or damages due to harsh chemicals (i.e. cleaning products improperly applied). The warrantor is not responsible for consequential or incidental damages.
- Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property, however arising.
- Important: Please retain the original proof of purchase to establish the warranty period.
- Any implied warranties of merchantability and fitness applicable to the equipment are limited in duration to the period of coverage of this express written warranty.
- This warranty grants specific legal rights to the purchaser. Other rights, which may vary from state to state, may also apply.
- Title to the merchandise passes to the consignee upon acceptance by the carrier. After acceptance by the carrier, the merchandise travels at the risk of the purchaser.
- In the event of freight damage, do not refuse shipment. Advise both the freight agent and the shipper of the damage.
- Note the details of that damage on the freight bill before any freight charges are paid and file a claim for damages with the freight agent.
Online Warranty Registration
- Register your Infratech heater online today and you’ll not only be covered by the most extensive three-year warranty in the industry – you’ll also be automatically enrolled in our Heater Maintenance Program.
- This means you can enjoy industry-leading customer support and receive free replacement end reflectors when needed, to keep your heating system looking as new as the day it was installed. Register at: Infratech-usa.com/warranty
- ©2023 INFRATECH
INFRATECH WARRANTY REGISTRATION
- Customer Name:————————————-
- Address:—————————————–
- City: State: Zip:———————————————
- Phone: E-mail:———————————————-
- Model #: Serial #:—————————————
- Dealer’s Name: Date Purchased:————————————–
- Dealer’s Address:——————————————————–
- This Warranty Registration Card must be returned within thirty days of purchase to properly activate your warranty.
- This information is for our internal use only.
- 344 W 157th Street Gardena, CA 90248
- TEL800-421-9455 or 310-354-1250
- FAX310-523-3674
- WWW.INFRATECH-USA.COM
Documents / Resources
|
Infratech CD-Series 61-1 4 Inch Dual Element 6000W 240V Electric Patio
Heater
[pdf] User Manual
CD-Series 61-1 4 Inch Dual Element 6000W 240V Electric Patio Heater, CD-
Series, 61-1 4 Inch Dual Element 6000W 240V Electric Patio Heater, 6000W 240V
Electric Patio Heater, 240V Electric Patio Heater, Electric Patio Heater,
Patio Heater
---|---
References
- Infratech Official Site - Premium Residential and Commercial Infrared Electric Heaters
- Warranty - Infratech Official Site
- Infratech Official Site - Premium Residential and Commercial Infrared Electric Heaters
- P65Warnings.ca.gov
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>