OXMART CP-700-2 Hydraulic Hand Pump Instruction Manual

June 1, 2024
OXMART

OXMART CP-700-2 Hydraulic Hand Pump

Hydraulic Hand PumpCP-70010000Psi

OXMART-CP-700-2-Hydraulic-Hand-Pump-FIG-4METHOD OF USE

OXMART-CP-700-2-Hydraulic-Hand-Pump-FIG-1

  • STEP1: Open the dust cover and connect to the male connector of other tools.
  • STEP2: Connect and tighten the connection to prevent oil leakage.
  • STEP3: Loosen the vent nut switch to prevent the fuel tank from being sealed.
  • STEP4: Tighten the oil return switch clockwise.
  • STEP5: Pressing the hydraulic pump will raise the piston of the hydraulic jack section.
  • STEP6: Loosen the pressure relief valve switch counterclockwise.
  • STEP7: The piston of the jack retracts on its own, tighten the ventilation nut switch to prevent fuel tank leakage

Note: Keep the open mode during use to facilitate the discharge of air.

Design advantages of the product

OXMART-CP-700-2-Hydraulic-Hand-Pump-FIG-2

About this item

  • [High Quality] – The hydraulic hand pump body has a smooth surface, good sealing and no oil leakage.
  • [Thick Packaging] – The manual pump is packed in thick corrugated cartons, which is effectively shockproof and can better protect the product.
  • [Humanized Design] – The non-slip comfortable handle provides a comfortable grip and is labor-saving to use.
  • [Wide Applications] – The pump can be used with hydraulic tools, such as hydraulic cylinder jacks, hydraulic campers, hydraulic punchers, hydraulic pipe benders, hydraulic flanges, etc., which can save effort and improve work efficiency.

Q&A

What if the pump doesn't work?

Firstly please check whether the connector is tightly connected. If the pump still doesn't work it usually means that hydraulic oil needs to be added.(Open the black cap on the rear to add the hydraulic oil.

What type of connector does this hydraulic pump use?

The connector adopts a threaded ZG3/8

How to judge the oil level of the pump?

The level of oil in the pump cannot be judged directly by eye yet. If the connector has been connected tightly, but the connected jack is still not risen then it means that the oil is not enough.

How to add hydraulic oil and what type of hydraulic oil should the pump add?

Open the vent nut switch at the end of the CP-700 hydraulic pump and add an appropriate amount of 15WT standard hydraulic oil.