Haier AD50S2SM3FA Multi Split Inverter Medium Pressure Indoor AC Unit Instruction Manual

June 1, 2024
Haier

Haier AD50S2SM3FA Multi Split Inverter Medium Pressure Indoor AC Unit

Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-AC-Unit-
product

Product Specifications

  • Model: MONOSPLIT DUCTED MEDIUM PRESSURE
  • Output Power (Cooling): 3.5 kW, 5.0 kW, 7.1 kW
  • Condensate Drain: Included with a maximum prevalence of 600mm
  • Control: Smart Control via hOn APP, WiFi-enabled
  • Fresh Air: Allows introduction of clean air into the room
  • UVC Sterilization: Built-in LED UV lights for killing airborne hazards
  • Air Distribution: Flexible with multiple installation solutions

Product Usage Instructions

Installation:

The unit has a compact design with a thickness of 248 mm for easy adaptation and installation. It includes a condensate drain pump for efficient drainage. Installation can be performed by gravity on both sides.

Control:

Utilize the Smart Control feature via the hOn APP or traditional wired/infrared control for functions like on/off, operation mode selection, fan speed adjustment, temperature control, air flow adjustment, scheduling, UV function, and steri-clean 56OC.

Fresh Air and UVC Sterilization:

The unit allows the introduction of fresh air into the room while the built-in LED UV lights ensure clean air by killing airborne hazards during circulation.

Air Distribution:

The ducted unit provides flexible air distribution options suitable for circular or rectangular channels.

FAQ

  • Q: Can the unit be controlled remotely?
    • A: Yes, the unit can be controlled remotely via the hOn APP using WiFi connectivity.
  • Q: Does the product come with a condensate drain pump?
    • A: Yes, the medium-pressure ducted units include a condensate drain pump as a standard feature.

COMPACT DESIGN

Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-
Indoor-AC-Unit-fig \(1\)

The unit has a thickness of 248 mm which allows better adaptation and ease of installation.

CONDENSATE DRAINHaier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-
Indoor-AC-Unit-fig \(2\)

The medium-pressure ducted units includes a condensate drain pump as standard. This guarantees a maximum prevalence of 600 mm measured from the base of the machine. There is the possibility of performing condensate drain by gravity (reversible on both sides).

EASY INSTALLATION

Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-
Pressure-Indoor-AC-Unit-fig \(3\)

  • The connection of electrical cables is now possible through only one screw.
  • The ducted units have two options for connecting the air extraction channel: rear or lower.

WiFi

Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-AC-
Unit-fig \(4\)

Besides normal wired/infrared control. Haier supplies Smart Control from hOn APP. Including the on/off. operation mode selection, fan speed temperature, and air flow adjustment, schedule, UV function and steri-clean 56OC, etc.

FRESH AIRHaier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-
AC-Unit-fig \(5\)

Air exchange allows introduction of clean air into the room.

UVC Sterilisation

The built-in LED UV lights kill airborne hazards when the air circulates from air inlet, ensuring the clean air out.

Flexible air distributionHaier-AD50S2SM3FA-Multi-Split-Inverter-Medium-
Pressure-Indoor-AC-Unit-fig \(6\)

The ducted units satisfy multiple installation solutions (circular or rectangular channels).

Dimension

AD35 – AD50 – AD71Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-
Indoor-AC-Unit-fig \(7\) Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-AC-
Unit-fig \(8\) Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-AC-Unit-fig
\(9\)

AD105 – AD125Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-
Indoor-AC-Unit-fig \(12\) Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-
AC-Unit-fig \(13\)

AD140 – AD160Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-
Indoor-AC-Unit-fig \(17\) Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-
AC-Unit-fig \(18\) Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-AC-Unit-fig
\(19\)

Specification

AD35 – AD50 – AD71Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-
Indoor-AC-Unit-fig \(10\)

  • Low noise level
  • Compact design
  • ‘Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without compromising the cooling capacity. Condensate drain pump
  • UCV Sterilisation
  • Wi-Fi control integrated
INDOOR UNIT Model   AD35S2SM3FA(H) AD50S2SM3FA(H) AD71S2SM3FA(H)

OUTDOOR UNIT

Performance data

| Model|  | 1U35S2SM1FA-2| 1U50S2SJ2FA-2| 1U71S2SR2FA
Output power – COOLING| nom (min-max)| kW| 3,50 (0,90-4,50)| 5,00 (1,80-6,00)| 7,10 (2,00-8,20)
Output power – HEATING| nom (min-max)| kW| 4,00 (1,00-4,80)| 6,00 (2,00-6,20)| 7,50 (2,50-8,50)
Absorbed power – COOLING| nom (min-max)| kW| 1,08 (0,28-1,80)| 1,55 (0,55-2,00)| 2,20 (0,50-3,00)
Absorbed power – HEATING| nom (min-max)| kW| 1,08 (0,28-1,80)| 1,48 (0,60-2,00)| 2,02 (0,60-3,00)
Energy class| EER| W/W| 3,23| 3,23| 3,23
COP| W/W| 3,71| 3,71| 3,71
COOLING Pdesign| 35 °C| kW| 3,50| 5,00| 7,10
HEATING Pdesign| (-10 °C)| kW| 2,70| 4,50| 5,00
Energy class| SEER|  | 6,10 (A++)| 6,10 (A++)| 6,10 (A++)
SCOP|  | 3,80 (A)| 3,80 (A)| 3,80 (A)
Annual Energy Consumption – COOLING| kWh/a| 215| 291| 406
Annual Energy Consumption – HEATING| kWh/a| 1020| 1782| 1827
Indoor Unit
Power supply|  | Ph/V/Hz| 1/220~240/50/60| 1/220~240/50/60| 1/220~240/50/60
Treated air volume| (H/M/L/Q)| m3/h| 840/720/600/450| 1020/900/780/550| 1440/1260/1100/900
External static pressure|  | Pa| 25(default)/37/50/70/90/100/110/120/130/150
High sound power|  | dB| 55| 56| 58
Sound pressure|  | dB(A)| 41/35/28/26| 43/37/30/28| 44/41/39/36
Net dimensions| WxDxH| mm| 700x700x248| 1100x700x248| 1100x700x248
Packaging dimensions| WxDxH| mm| 914x866x318| 1316x866x318| 1316x866x318
Net/gross weight|  | kg| 26,0/30,0| 31,0/35,0| 31,0/35,0
Outdoor Unit
Power supply|  | Ph/V/Hz| 1/220~240/50| 1/220~240/50| 1/220~240/50/60
Power cable|  | N x mm2| 3 x 1,5| 3 x 1,5| 3 x 4,0
Interconnection cable|  | N x mm2| 4 x 1,0| 4 x 1,0| 4 x 2,5
Sound power| H| dB| 61| 63| 67
Sound pressure| H| dB(A)| 48| 50| 54
Running current cooling/heating| Max| A| 8,0| 10,68| 13,1
Starting current cooling/heating| Max| A| 2,0| 2,0| 2,0
Net dimensions| WxDxH| mm| 800x275x553| 820x305x643| 890x340x700
Packaging dimensions| WxDxH| mm| 902x375x607| 940x390x697| 1046x460x780
Net/gross weight|  | kg| 30,0/32,9| 35,7/38,5| 45,0/50,0
Compressor type|  |  | Rotary inverter| Rotary inverter| Twin rotary inverter
Installation data
Refrigerant|  |  | R32| R32| R32
Liquid pipe| Ø| mm (inch)| 6,35 (1/4)| 6,35 (1/4)| 9,52 (3/8)
Gas pipe| Ø| mm (inch)| 9,52 (3/8)| 12,70 (1/2)| 15,88 (5/8)
Standard pipe length without refrigerant charge| m| 7| 7| 10
Maximum pipe length|  | m| 20| 25| 50
Maximum IU – OU elevation|  | m| 10| 15| 30
Refrigerant charge in the factory|  | kg| 0,78| 1,10| 1,30
Refrigerant charge in the factory|  | TCO2eq| 0,53| 0,74| 0,88
Additional ref. charge over std length| g/m| 20| 20| 45
Outdoor operating limits – COOLING| min-max| °C| -20~46
Outdoor operating limits – HEATING| min-max| °C| -20~24

AD105 – AD125Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-
Indoor-AC-Unit-fig \(15\)

  • Low noise level
  • Compact design
  • ‘Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without compromising the cooling capacity. Condensate drain pump
  • UCV Sterilisation
  • Wi-Fi control integrated

INDOOR UNIT| Model|  | AD105S2SM3FA(H)| AD105S2SM3FA(H)| AD125S2SM8FA(H)| AD125S2SM8FA(H)
---|---|---|---|---|---|---
OUTDOOR UNIT

Performance data

| Model|  | 1U105S2SS2FA| 1U105S2SS1FB| 1U125S2SN2FA| 1U125S2SN2FB
Output power – COOLING| nom (min-max)| kW| 9,50 (2,50-10,00)| 9,50 (2,50-10,00)| 12,30 (3,00-13,00)| 12,40 (3,00-13,00)
Output power – HEATING| nom (min-max)| kW| 10,20 (3,00-10,50)| 10,50 (3,00-11,00)| 12,70 (3,50-13,50)| 12,80 (3,50-13,50)
Absorbed power – COOLING| nom (min-max)| kW| 3,16 (0,50-4,00)| 3,27 (0,50-4,00)| 4,60 (1,00-6,00)| 4,51 (1,00-6,00)
Absorbed power – HEATING| nom (min-max)| kW| 2,91 (0,50-4,00)| 3,00 (0,50-4,00)| 3,93 (1,00-6,00)| 3,87 (1,00-6,00)
Energy class| EER| W/W| 3,01| 2,90| 2,67| 2,75
COP| W/W| 3,50| 3,50| 3,23| 3,31
COOLING Pdesign| 35 °C| kW| 9,50| 9,50| 12,30| 12,40
HEATING Pdesign| (-10 °C)| kW| 7,20| 6,00| 8,00| 8,00
Energy class| SEER|  | 6,10 (A++)| 6,00 (A+)| 5,72 (A+)| 5,85 (A+)
SCOP|  | 3,80 (A)| 3,91 (A)| 3,93 (A)| 3,96 (A)
Annual Energy Consumption – COOLING| kWh/a| 544| 569| 735| 718
Annual Energy Consumption – HEATING| kWh/a| 2792| 2094| 3032| 3003
Indoor Unit
Power supply|  | Ph/V/Hz| 1/220~240/50/60| 1/220~240/50/60| 1/220~240/50/60| 1/220~240/50/60
Treated air volume| (H/M/L/Q)| m3/h| 1600/1480/1360/1240| 1600/1480/1360/1240| 2250/1960/1680/1500| 2250/1960/1680/1500
External static pressure|  | Pa| 25/37(default)/50/70/90/100/110/120/130/150
High sound power|  | dB| 61| 64| 65| 65
Sound pressure|  | dB(A)| 47/44/40/37| 47/44/40/37| 48/45/42/39| 48/45/42/39
Net dimensions| WxDxH| mm| 1500x700x248| 1500x700x248| 1500x700x248| 1500x700x248
Packaging dimensions| WxDxH| mm| 1711x870x325| 1711x870x325| 1711x870x325| 1711x870x325
Net/gross weight|  | kg| 46,0/55,0| 46,0/55,0| 48,0/57,0| 48,0/57,0
Outdoor Unit
Power supply|  | Ph/V/Hz| 1/220~240/50/60| 3/380~415/50/60| 1 /220~240/ 50/60| 3 /380-415/ 50/60
Power cable|  | N x mm2| 3 x 4,0| 5 x 4,0| 3 x 6,0| 5 x 4,0
Interconnection cable|  | N x mm2| 4 x 2,5| 4 x 2,5| 4 x 2,5| 4 x 2,5
Sound power| H| dB| 66| 68| 72| 72
Sound pressure| H| dB(A)| 53| 54| 58| 58
Running current cooling/heating| Max| A| 16,5| 6,8| 26,0| 10,0
Starting current cooling/heating| Max| A| 3,0| 1,0| 4,0| 2,0
Net dimensions| WxDxH| mm| 920372765| 920372765| 950x370x965| 950x370x965
Packaging dimensions| WxDxH| mm| 1036478820| 1085x485x830| 1050x485x1130| 1050x485x1130
Net/gross weight|  | kg| 60,0/65,0| 61,0/66,0| 84,0/89,0| 85,0/90,0
Compressor type|  |  | Twin rotary inverter| Twin rotary inverter| Twin rotary inverter| Twin rotary inverter
Installation data
Refrigerant|  |  | R32| R32| R32| R32
Liquid pipe| Ø| mm (inch)| 9,52 (3/8)| 9,52 (3/8)| 9,52 (3/8)| 9,52 (3/8)
Gas pipe| Ø| mm (inch)| 15,88 (5/8)| 15,88 (5/8)| 15,88 (5/8)| 15,88 (5/8)
Standard pipe length without refrigerant charge| m| 30| 30| 30| 30
Maximum pipe length|  | m| 50| 50| 50| 50
Maximum IU – OU elevation|  | m| 30| 30| 30| 30
Refrigerant charge in the factory|  | kg| 1,70| 1,70| 2,30| 2,30
Refrigerant charge in the factory|  | TCO2eq| 1,15| 1,15| 1,55| 1,55
Additional ref. charge over std length| g/m| 45| 45| 45| 45
Outdoor operating limits – COOLING| min-max| °C| -20~46
Outdoor operating limits – HEATING| min-max| °C| -20~24

AD140 – AD160

Haier-AD50S2SM3FA-Multi-Split-Inverter-Medium-Pressure-Indoor-AC-Unit-fig
\(20\)

  • Low noise level
  • Compact design
  • ‘Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without compromising the cooling capacity. Condensate drain pump
  • UCV Sterilisation
  • Wi-Fi control integrated

INDOOR UNIT                               Model AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD160S2SM3FA(H)

OUTDOOR UNIT                            Model 1U140S2SN1FA    1U140S2SN1FB       1U140S2SP2FA       1U140S2SP2FB 1U160S2SP1FB

Performance data

Output power – COOLING| nom (min-max)| kW| 13,40 (3,50-14,00)| 13,40 (3,50-14,00)| 13,40 (4,00-15,00)| 13,40 (4,00-15,00)| 16,00 (4,50-16,50)
Output power – HEATING| nom (min-max)| kW| 15,00 (4,00-15,50)| 15,00 (4,00-15,50)| 15,00 (4,50-16,00)| 15,00 (4,50-16,00)| 17,00 (5,00-18,00)
Absorbed power – COOLING| nom (min-max)| kW| 5,28 (1,00-6,50)| 5,18 (1,00-6,50)| 4,17 (1,00-6,00)| 4,15 (1,00-6,00)| 5,48 (1,00-6,50)
Absorbed power – HEATING| nom (min-max)| kW| 4,92 (1,00-6,50)| 4,79 (1,00-6,50)| 4,04 (1,00-6,00)| 4,02 (1,00-6,00)| 4,82 (1,00-6,50)
Energy class| EER| W/W| 2,54| 2,59| 3,21| 3,23| 2,92
COP| W/W| 3,05| 3,13| 3,71| 3,73| 3,53
COOLING Pdesign| 35 °C| kW| 13,40| 13,40| 13,40| 13,40| 16,00
HEATING Pdesign| (-10 °C)| kW| 8,50| 8,50| 11,00| 11,00| 11,00
Energy class| SEER|  | 5,62 (A+)| 5,64 (A+)| 6,16 (A++)| 6,19 (A++)| 5,94 (A+)
SCOP|  | 3,93 (A)| 3,96 (A)| 4,06 (A+)| 4,06 (A+)| 4,06 (A+)
Annual Energy Consumption – COOLING| kWh/a| 835| 832| 761| 758| 943
Annual Energy Consumption – HEATING| kWh/a| 3032| 3003| 3796| 3798| 3798
Indoor Unit
Power supply|  | Ph/V/Hz| 1/220~240/50/60| 1/220~240/50/60| 1/220~240/50/60| 1/220~240/50/60| 1/220~240/50/60
Treated air volume| (H/M/L/Q)| m3/h| 2500/2160/1780/1500| 2500/2160/1780/1500| 2500/2160/1780/1500| 2500/2160/1780/1500| 2500/2160/1780/1500
External static pressure|  | Pa| 25/37(default)/50/70/90/100/110/120/130/150
High sound power|  | dB| 66| 66| 66| 66| 67
Sound pressure|  | dB(A)| 48/45/42/39| 48/45/42/39| 48/45/42/39| 48/45/42/39| 48/45/42/39
Net dimensions| WxDxH| mm| 1500x700x248| 1500x700x248| 1500x700x248| 1500x700x248| 1500x700x248
Packaging dimensions| WxDxH| mm| 1711x870x325| 1711x870x325| 1711x870x325| 1711x870x325| 1711x870x325
Net/gross weight|  | kg| 48,0/57,0| 48,0/57,0| 48,0/57,0| 48,0/57,0| 48,0/57,0
Outdoor Unit
Power supply|  | Ph/V/Hz| 1 /220~240/ 50/60| 3 /380-415/ 50/60| 1/220~240/50/60| 3/380~415/50/60| 3/380~415/50/60
Power cable|  | N x mm2| 3 x 6,0| 5 x 4,0| 3 x 6,0| 5 x 4,0| 5 x 4,0
Interconnection cable|  | N x mm2| 4 x 2,5| 4 x 2,5| 4 x 2,5| 4 x 2,5| 4 x 2,5
Sound power| H| dB| 72| 72| 70| 70| 72
Sound pressure| H| dB(A)| 58| 58| 53| 53| 58
Running current cooling/heating| Max| A| 30,0| 10,0| 32,0| 10,0| 10,0
Starting current cooling/heating| Max| A| 5,0| 2,0| 6,0| 2,0| 2,0
Net dimensions| WxDxH| mm| 950x370x965| 950x370x965| 950x370x1350| 950x370x1350| 950x370x1350
Packaging dimensions| WxDxH| mm| 1050x485x1130| 1050x485x1130| 1050x485x1500| 1050x485x1500| 1050x485x1500
Net/gross weight|  | kg| 84,0/89,0| 85,0/90,0| 105,0/118,0| 101,0/116,0| 101,0/116,0
Compressor type|  |  | Twin rotary inverter| Twin rotary inverter| Twin rotary inverter| Twin rotary inverter| Twin rotary inverter
Installation data
Refrigerant|  |  | R32| R32| R32| R32| R32
Liquid pipe| Ø| mm (inch)| 9,52 (3/8)| 9,52 (3/8)| 9,52 (3/8)| 9,52 (3/8)| 9,52 (3/8)
Gas pipe| Ø| mm (inch)| 15,88 (5/8)| 15,88 (5/8)| 15,88 (5/8)| 15,88 (5/8)| 19,05 (3/4)
Standard pipe length without refrigerant charge| m| 30| 30| 30| 30| 30
Maximum pipe length|  | m| 70| 70| 70| 70| 70
Maximum IU – OU elevation|  | m| 30| 30| 30| 30| 30
Refrigerant charge in the factory|  | kg| 2,30| 2,30| 2,90| 3,50| 3,50
Refrigerant charge in the factory|  | TCO2eq| 1,55| 1,55| 1,96| 2,36| 2,36
Additional ref. charge over std length| g/m| 45| 45| 45| 45| 45
Outdoor operating limits –

COOLING

| min-max| °C| -20~46
Outdoor operating limits – HEATING| min-max| °C| -20~24

The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals