VENT-FREE GAS SYSTEM
OWNER’S OPERATION AND INSTALLATION MANUAL
MODELS FDF400T-ZC SERIES CSA/ANS
Z21.11.2 2019
Unvented Room Heaters
PFS F09-065
FDF400T-ZC Dual Fuel Ventless Gas Fireplace Insert
WARNING: If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury or loss
of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
WARNING: This appliance is equipped for natural and propane gas. Field
conversion is not permitted other than between natural or propane gases.
Questions, problems, missing parts?
Before returning to your retailer, call our customer service department at
1-855-607-6557, 8:00 am – 4:30 pm CST,
Monday through Friday or email
contact@factorybuysdirect.com
SAVE THIS BOOK
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air
must be provided.
Refer to Air For Combustion and Ventilation section on page 8 of this manual.
**WARNING:* FIRE, EXPLOSION AND ASPHYXIATION HAZARD
Improper adjustment, alteration, service, maintenance, or installation of this
heater or its controls can cause death or serious injury.
Read and follow instructions and precautions in User’s Information Manual
provided with this heater.
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with propane or natural gas.
This appliance is equipped with a simple means toswitch between propane and
natural gas.
Field conversion by any other means including the use of a kit is not
permitted.
- Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
PATENT INFORMATION
This product may be covered by one or more of the following United States
patents:
9,829,195 9,423,123 9,441,833 9,518,732 9,752,779 9,416,977 8,764,436,
8,568,136 8,516,878 8,297,968 8,281,781 8,235,708 7,967,006, 7,967,007
7,730,765 7,677,236 7,607,426 7,434,447
SAFETY
IMPORTANT: Read this owner’s manual carefully and completelybefore trying
to assemble, operate, or service this heater.Improper use of this heater can
cause serious injury or death from burns, fire, explosion,electrical shock and
carbonmonoxide poisoning. Failureto follow these instructions will void the
warranty.
Only a qualified installer, serviceagent, or local gas supplier may install
and service this product.
This appliance is equipped with an automatic selector device thatallows it to
operate with propaneor natural gas
WARNING: Keep the appliance area clear and free from combustible
materials, gasoline, and other flammable vapors and liquids.
DANGER: Carbon monoxide poisoning may lead to death!
CARBON MONOXIDE POISONING:
Early signs of carbon monoxide poisoning resemble the flu, with headaches,
dizziness or nausea. If you have these signs, the heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people are more affected by carbon monoxide than others. These include
pregnant women, people with heart or lung disease or anemia, those under the
influence of alcohol and those at high altitudes.
NATURAL AND PROPANE GAS:
Natural and propane gas are odorless. An odormaking agent is added to the gas.
The odor helps you detect a gas leak.
However, the odor added to the gas can fade.
Gas may be present even though no odor exists.
WARNING: Do not allow fans to blow directly into fireplace.
Avoid any drafts that alter burner flame patterns.
WARNING: Do not use a blower insert, heat exchange insert or other
accessory not approved for use with this heater.
WARNING: Due to high temperatures, the appliance should be located out of
traffic and away from furniture and draperies.
WARNING: Do not place clothing or other flammable material on or near the
appliance.
Never place any objects in the fireplace.
WARNING: Fireplace becomes very hot when running.
Keep children and adults away from hot surfaces to avoid burns or clothing
ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces
to cool before touching.
WARNING: Carefully supervise young children when they are in the room
with the heater.
Toddlers, young children and others may be susceptible to accidental contact
burns.
A physical barrier is recommended if there are at risk individuals in the
house.
To restrict access to a fireplace or stove, install an adjustable safety gate
to keep toddlers, young children and other at risk individuals out of the room
and away from hot surfaces.
WARNING: The fire screen or guard designed for this unvented appliance
must be installed prior to operation.
-
Do not place propane supply tank(s)inside any structure. Propane supply tank(s) must be placed outdoors.
-
This heater should not be installed in a bedroom or bathroom.
-
This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system.
The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 8. If heater keeps shutting off, see Troubleshooting, page 25. -
Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for proper combustion.
-
If heater shuts off, do not relight until you have provided fresh, outside air. If heater keeps shutting off, have it serviced.
-
Do not run heater:
• Where flammable liquids or vapors are used or stored.
• Under dusty conditions. -
Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off.
If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. -
Always run heater with control knob at PILOT/IGN or ON (1 thru 5) positions. never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
-
Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
-
Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.
-
Operating heater above elevations of 4,500 feet could cause pilot outage.
-
To prevent performance problems, do not use propane fuel tank of less than 100 lbs. capacity.
-
Do not use this heater as a wood-burning heater. Use only the logs provided with the heater.
-
To prevent the creation of soot, follow the instructions under Care and Maintenance page 22.
-
Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting.
Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater. -
This log heater is designed to be smokeless.
If logs ever appear to be smoking, turn off heater and call a qualified service technician.
NOTE: During initial operating, slight smoking could occur due to log curing and heater burning off manufacturing residues. -
Solid fuels should not be burned in fireplace in which a vent-free log set is installed. Do not use this heater to cook food or burn paper or other objects.
-
Do not use this heater if any log is broken. Do not operate heater if a log is chipped (dime-size or larger).
SPECIFICATIONS
FDF400T-ZC
Gas Type| Natural| Propane
Maximum Input Rating| 32,000 BTU/Hr| 32,000 BTU/Hr
Minimum Input Rating| 14,500 BTU/Hr| 24,500 BTU/Hr
Regulator Pressure Setting| 4″ W.C.| 9″ W.C.
Inlet Gas Pressure*
(inches of water)| Max. 9.5″ W.C.| Max. 14″ W.C.
Min. 5″ W.C.| Min. 11″ W.C.
Ignition| Electronic Piezo Ignitor
Heater Dimensions (H x W x D)| 29.5″ x 29.1″ x 15.6″
Carton Dimensions (H x W x D)| 31.1″ x 31.5″ x 18.1″
Stove Weight| 69.5 lbs.
Shipping Weight| 79.5 lbs.
- For purposes of input adjustment.
QUALIFIED INSTALLING AGENCY
Only a qualified agency should install and replace gas piping, gas utilization
equipment or accessories, and repair and equipment servicing.
The term “qualified agency” means any individual, firm, corporation, or
company that either in person or through a representative is engaged in and is
responsible for: a) Installing, testing, or replacing gas piping or b)
Connecting, installing, testing, repairing, or servicing equipment; that is
experienced in such work; that is familiar with all precautions required; and
that has complied with all the requirement of the authority having
jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff
system.
The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic piezo control system. This system
requires AAA batteries (provided).
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner on and off to maintain a desired
room temperature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either propane or natural gas. The
heater is shipped from the factory ready for connecting to propane.
The heater can easily be changed to Natural gas by having your qualified
installer follow the instructions on page 10 and the markings on the heater.
PRODUCT IDENTIFICATION
UNPACKING
- Remove top inner pack.
- Tilt carton so that heater is upright.
- Remove protective side packaging.
- Slide heater out of carton.
- Remove protective plastic wrap.
- Hold the screen, lift, and pull forward.
- Remove log set by cutting plastic ties.
- Carefully unwrap log.
- Check for any shipping damage. If heater or log is damaged, promptly inform your dealer where you bought the heater.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of
local codes, use the latest edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
Available from:
American National Standards Institute, Inc.
25 West 43rd Street New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park Quincy, MA 02269-9101
State of Massachusetts: The installation must be made by a licensed
plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental room heaters
shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
In the State of Massachusetts the gas cock must be a T-handle type. The State
of Massachusetts requires that a flexible appliance connector cannot exceed
three feet in length.
WATER VAPOR: A BY PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An unvented room heater
produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs
(0.3 KWs) of gas input per hour.
Unvented room heaters are recommended as supplemental heat (a room) rather
than a primary heat source (an entire house).
In most supplemental heat applications, the water vapor does not create a
problem. In most applications, the water vapor enhances the low humidity
atmosphere experienced during cold weather.
The following steps will help ensure that water vapor does not become a
problem.
- Be sure the heater is sized properly for the application, including ample combustion air and circulation air.
- If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.
- Do not use an unvented room heater as the primary heat source.
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not be installed in a confined space or
unusually tight construction unless provisions are provided for adequate
combustion and ventilation air.
Read the following instructions to insure proper fresh air for this and other
fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials,
increased insulation and new construction methods help reduce heat loss in
homes. Home owners weather strip and caulk around windows and doors to keep
the cold air out and the warm air in.
During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to
breathe. Fresh air must enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air
from the house to operate. You must provide adequate fresh air for these
appliances. This will insure proper venting of vented fuel-burning appliances.
WARNING: This heater shall not be installed in a room or space unless the
required volume of indoor combustion air is provided by the method described
in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas
Code, or applicable local codes.
WARNING: If the area in which the heater may be operated does not meet
the required volume for indoor combustion air, combustion and ventilation air
shall be provided by one of the methods described in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable
local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating
to an adjoining unconfined space, you must provide two permanent openings: one
within 12″ of the ceiling and one within 12″ of the floor on the wall
connecting the two spaces (see options 1 and 2, Figure 2). You can also remove
door into adjoining room (see option 3, Figure 2).
Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and
Ventilation for required size of ventilation grills or ducts. Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide
two permanent openings: one within 12″ of the ceiling and one within 12″ of
the floor. Connect these items directly to the outdoors or spaces open to the
outdoors.
These spaces include attics and crawl spaces. Follow the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required
size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet air into attic if
attic has a thermostat-controlled power vent. Heated air entering the attic
will activate the power vent.
Rework worksheet, adding the space of the adjoining unconfined space. The
combined spaces must have enough fresh air to supply all appliances in both
spaces.
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat.
Use this heater along with your primary heating system. Do not install this
heater as your primary heat source. If you have a central heating system, you
may run system’s circulating blower while using heater. This will help
circulate the heat throughout the house. In the event of a power outage, you
can use this heater as your primary heat source.
WARNING: A qualified service person must install heater.
Follow all local codes.
WARNING: Before installing in a solid fuel burning fireplace, the chimney
flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a
qualified chimney cleaner.
Creosote will ignite if highly heated. A dirty chimney flue may create and
distribute soot within the house. Inspect chimney flue and firebox for damage.
If damaged, repair flue before operating heater.
WARNING: Seal any fresh air vents or ash clean-out doors located on floor
or wall of fireplace.
If not, drafting may cause pilot outage or sooting. Use a heat-resistant
sealant. Do not seal chimney flue damper.
WARNING: Never install the heater
- in a bedroom or bathroom
- in a recreational vehicle
- where curtains, furniture, clothing, or other flammable objects are less than 42″ from the front, top, or sides of the heater.
- in high traffic areas
- in windy or drafty areas
CAUTION: This heater creates warm air currents. These currents move heat
to wall surfaces next to heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such as tobacco smoke,
aromatic candles, cleaning fluids,
oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause
odors.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is
beneficial, installing heater in rooms without enough ventilation air may
cause mildew to form too much moisture. See Air for Combustion and
Ventilation, page 8.
CHECK GAS TYPE
Be sure your gas supply is right for your heater.
Otherwise, call dealer where you bought the heater for proper type heater.
GAS SELECTION
This appliance is factory preset for propane gas. No changes are required
for connecting to propane. Only a qualified installer or service technician
can perform gas selection and connecting to gas supply.
CAUTION: Two gas line installations at the same time are prohibited.
CAUTION: To avoid gas leakage for the gas not being used at the inlet of
regulator, a qualified installer or service technician must use supplied cap.
You will notice a color coded plunger on the inside of the regulator.
This is normal.
When the inlet connection fitting is inserted and tightened, this plunger will
be pushed back by the fitting making all of the adjustments for the gas being
supplied. DO NOT REMOVE THE PLUNGER.
The regulator will not work and the warranty will be voided.
The inlet regulator is color coded for identification of the correct gas type.
Blue is for propane gas and yellow is for natural gas.
FOR PROPANE GAS INSTALLATION: BLUE
Apply thread sealant to the threads on the connection fitting. While pushing
in, rotate the fitting clockwise until the threads engage the regulator. After
the fitting has been hand tightened into the regulator use a wrench to
complete tightening of the fitting. Install additional fitting to connect to
the house supply.
FOR NATURAL GAS INSTALLATION: YELLOW
- Remove the metal cap installed over the NG regulator inlet.
- Install metal cap over propane regulator inlet. This will keep debris out of regulator. Use only the cap supplied on the regulator. Do not use an off the shelf pipe plug. This can damage the plunger. The supplied regulator cap is designed so it will not engage the unused gas type.
- Apply thread sealant to the threads on the connection fitting. While pushing in, rotate the fitting clockwise until the threads engage the regulator. After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting. Install additional fitting to connect to the house supply.
Use only the metal cap. DO NOT use an off the shelf 3/8″ NPT pipe cap. This
will damage the plungers located inside the regulator.
DO NOT TRY TO REMOVE THE PLUNGERS FROM INSIDE THE REGULATOR. THE PLUNGER WILL
BE PUSHED BACK AS THE FITTING IS INSTALLED. REMOVING THE PLUNGERS WILL VOID
THE WARRANTY.
Make sure the type of gas being used is correct. Check to make sure the
connection fitting is in the correct inlet on the regulator.
Refer to Connecting to Gas Supply, page 14.
If you are using natural gas and the pilot will not light, see
Troubleshooting, page 25.
CLEARANCES TO COMBUSTIBLES
WARNING: You must maintain the minimum clearances.
If possible, provide greater clearances from floor, ceiling, and adjoining
wall. Measure from outermost point of heater.
Note: This firebox can not be installed in an existing fireplace. Install
this firebox only in a ProCom Heating, Inc. mantel accessory approved for this
product.
Minimum Clearances For Side Combustible Material, Side Wall and Ceiling
A. Clearance from the side of the fireplace to any combustible material and
wall should not be less than 12″ (see Figure5).
B. Clearance from the top of the fireplace to the ceiling must not be less
than 48″.
MANTEL ( IF APPLICABLE )
Assemble and install your mantel at this time. Mantel instructions are inside
the mantel box. Mantel must be in place before you connect to the gas supply.
BUILT IN FIREPLACE INSTALLATION
WARNING: Do not allow any combustible materials to overlap the firebox
front.
WARNING: Do not allow combustible or noncombustible materials to cover
any necessary openings like louvered slots.
WARNING: Never modify or cover the louvered slots on the front of the
firebox.
Built-in installation of this fireplace involves installing fireplace into a
framed-in enclosure.
This makes the front of the fireplace flush with wall. If installing a built-
in mantel above the fireplace, you must follow the clearances shown in Figure
6, page 13.
NOTICE: Surface temperatures of adjacent walls and mantels become hot
during operation.
Walls and mantels above the fireplace may become hot to the touch. If
installed properly, these temperatures meet the requirement of the national
product standard. Follow all minimum clearances shown in this manual (see
Figure 6, page 13).
-
Frame in rough opening. Use dimensions shown in Figure 7 for the rough opening. If installing in a corner, use dimensions shown in Figure 9, for the rough opening.
The height is 23 1/4″, which is the same as the wall opening above. -
Locate standoff brackets in the hardware bag. Remove screws from the top of the firebox. Install brackets with screws as shown in Figure 10.
-
Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
-
Attach gas line to fireplace gas regulator.
See Connecting to Gas Supply, page 14. -
Check all gas connections for leaks. See Checking Gas Connections, page 16.
CONNECTING TO GAS SUPPLY
WARNING: A qualified service technician must connect heater to gas supply.
Follow all local codes.
WARNING: This appliance requires a 3/8″ NPT (National Pipe Thread) inlet
connection to the pressure regulator.
WARNING: Do not overtighten gas connections.
WARNING: For natural gas, Never connect heater to private (non-utility)
gas wells. This gas is commonly known as wellhead gas.
CAUTION: For propane gas, never connect heater directly to the gas
supply. This heater requires an external regulator (not supplied). Install the
external regulator between the heater and propane supply. Gas supplier
provides external regulator for natural gas. The installer provides the
external regulator for propane gas.
CAUTION: Use only new, black iron or steel pipe. Internally tinned copper
tubing may be used in certain areas.
Check your local codes. Use pipe of 1/2″ diameter or greater to allow proper
gas volume to heater. If pipe is too small, undue loss of pressure will occur.
CAUTION: For natural gas, check your gas line pressure before connecting
heater to gas line. Gas line pressure must be no greater than 9.5″ WC. If gas
line pressure is higher, heater regulator damage could occur.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when
connecting into gas piping and/or fittings.
CAUTION: Use pipe joint sealant that is resistant to gas (Propane or
Natural Gas).
Before installing heater, make sure you have the items listed below:
-
external regulator for propane unit only (supplied by installer)
-
piping (check local codes)
-
sealant (resistant to natural gas and pro- pane gas)
-
equipment shutoff valve*
-
test gauge connection*
-
sediment trap
-
tee joint
-
pipe wrench
-
flexible gas hose (check local codes)
-
3/8″ NPT brass fitting
-
A CSA design-certified equipment shutoff valve with 1/8″ NPT tap is an acceptable alternative to test gauge connection.
Purchase the optional CSA design certified equipment shutoff valve from your dealer.
Typical Inlet Pipe Diameters
Use 3/8″ black iron pipe or greater. Installation must include an equipment
shutoff valve, union, and plugged 1/8″ NPT tap. Locate NPT tap within reach
for test gauge hook up.
NPT tap must be upstream from heater (see Figure 11).
IMPORTANT: Install an equipment shutoff valve in an accessible location.
The equipment shutoff valve is for turning on or shutting off the gas to the
appliance.
Apply pipe joint sealant lightly to male threads.
This will prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged heater valves.
For propane gas, the installer must supply an external regulator. The external
regulator will reduce incoming gas pressure. You must reduce incoming gas
pressure to between 11″ and 14″ of water. If you do not reduce incoming gas
pressure, heater regulator damage could occur. Install external regulator
with the vent pointing down as shown in Figure 12.
Pointing the vent down protects it from freezing rain or sleet.
Install sediment trap in supply line as shown in Figure 11. Place sediment
trap where it is within reach for cleaning. Place sediment trap where trapped
matter is not likely to freeze.
A sediment trap traps moisture and contaminants.
This keeps them from going into heater controls.
If sediment trap is not installed or is installed wrong, heater may not run
properly.
WARNING: Test all gas piping and connections for leaks after installing
or servicing. Correct all leaks at once (see page 16).* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections, internal and external to unit,
for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a
noncorrosive leak detection fluid to all joints. If bubbles form, there is a
leak. Correct all leaks at once.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
-
Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system.
Pressures in excess of 1/2 PSIG will damage heater regulator. -
Cap off open end of gas pipe where equipment shutoff valve was connected.
-
Pressurize supply piping system by eitheropening propane supply tank valve forpropane gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
-
Check all joints of gas supply piping system. Apply noncorrosive leak detectionfluid to all joints. If bubbles form, theremay be a leak.
-
Correct all leaks at once.
-
Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
- Close equipment shutoff valve (see Figure 13).
- Pressurize supply piping system by either opening propane supply tank valve for propane gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
- Check all joints from gas meter to equipment shutoff valve for natural gas or propane supply to equipment shutoff valve for propane (see Figure 14 or 15). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.
- Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
- Open equipment shutoff valve (see Figure 13).
- Open main gas valve located on or near gas meter for natural gas or open propane supply tank valve.
- Make sure control knob of heater is in the OFF position.
- Check all joints from equipment shutoff valve to control valve (see Figure 14 or 15). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.
- Correct all leaks at once.
- Light heater (see Lighting Instructions on page 19). Check all other internal joints for leaks.
- Turn off heater (see To Turn Off Gas Ap- pliance, page 20).
INSTALLING LOGS
WARNING: Failure to position the parts in accordance with these diagrams
or failure to use only parts specifically approved with this heater may result
in property damage or personal injury.
CAUTION: After installation and periodically thereafter, check to ensure
that no yellow flame comes in contact with any log. With the heater set to
High, check to see if yellow flames contact any log. If so, reposition logs
according to the log installation instructions in this manual. Yellow flames
contacting logs will create soot.
It is very important to install the logs exactly as instructed. Do not modify
logs. Use only logs supplied with heater. Each log is marked with a number.
This number will help you to identify the logs when installing. After
installing logs, add decorative cinders around the grate base, do not place
any decorative cinders on logs or burner.
- Install pins on log #1 into the two slots in the bracket attached to rear wall (see Figure 17).
- Install pins on log #2 into the two slots in left side of the middle bracket (see Figure 16 and Figure 17).
- Install pins on log #3 into the two slots in right side of the middle bracket (see Figure 16 and Figure 17).
- Install pins on log #4 onto the two slots in the front bracket (see Figure 17 and Figure 18).
- Insert the recessed hole on the bottom of log #5 onto the pin on log #2 (see Figures 17 and 18,).
- Insert the recessed hole of log #6 onto the pin on log #3 (see Figures 17 and 18,).
IMPORTANT: Make sure logs do not cover any burner ports. It is very important to install the logs exactly as instructed. Do not modify logs. Use only logs supplied with heater.
INSTALLING BATTERIES
CAUTION: Do not dispose of batteries in fire, batteries may explode or leak.
Figure 20 – Installing Battery in Ignitor
-
Batteries are included.
-
Remove batteries when depleted.
-
Be sure to observe proper polarity (+/-) when installing or replacing the batteries.
Damage due to improper battery installation may void the warranty on the product. -
For long periods of non-operation, remove batteries from all components for safety.
Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.
OPERATION
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools.
If the knob will not push in or turn by hand, don’t try to repair it, call a
qualified service technician. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under water. Immediately
call a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING: You must operate this heater with the screen in place. Make sure
screen is installed before running heater.
NOTICE: During initial operation of new heater, burning logs will give
off a paper-burning smell. Orange flame will also be present. Open damper or
window to vent smell.
This will only last a few hours.
-
STOP! Read the safety information above.
-
Open screen.
-
Make sure equipment shutoff valve is fully open.
-
Turn control knob clockwise to the OFF position (see Figure 21).
-
Wait five (5) minutes to clear out any gas. Then smell for gas around heater and near the floor. If you smell gas, STOP!
Follow “B” in the safety information above.
If you do not smell gas, go to the next step. -
Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds.
Note: The first time that the heater is operated after connecting the gas supply, the control knob should be pressed for about thirty (30) seconds. This will allow air to bleed from the gas system. If pilot does not stay lit, refer to Troubleshooting, pages 24 though 27. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match.
• If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs. -
With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to Troubleshooting, pages 24 though 27.
Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure. -
Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 5 through 8. This heater has a safety interlock system.
Wait one (1) minute before lighting pilot again. -
Turn control knob counterclockwise to the desired heating level. The main burner should light. Set control knob between High (5) and Low (1).
Note: Please wait one minute after shutting off heater to allow the control valve to reset before starting again. -
Make sure heater screen is in place before operating heater.
-
If heater will not operate, follow the instructions To Turn Off Gas To Appliance, and call your service technical or gas supplier.
CAUTION: Do not try to adjust heating levels by using the equipment
shutoff valve.
WARNING: If input gas type is NG, make sure NG pilot burner ignites. If
input gas type is LP, make sure LP pilot burner ignites.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise to the OFF position.
Shutting Off Burner Only
(pilot stays lit)
Turn control knob clockwise to the PILOT position.
MANUAL LIGHTING PROCEDURE
- Open screen.
- Follow steps 1 through 7 under Lighting Instructions, page 19.
- With control knob in the PILOT position, strike a match, and hold near pilot. Press in control knob; pilot should light.
- Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
- Make sure the heater screen is in place before operating heater.
INSPECTING BURNERS
IMPORTANT: Owner’s should check pilot flame pattern and burner flame
pattern often.
Incorrect flame patterns indicate the need for cleaning (see Care and
Maintenance, page 22) or service.
WARNING: Only a qualified service person should service and repair
heater. This includes maintenance requiring replacement or alteration of
components.
PILOT FLAME PATTERN
Figure 23 shows a correct pilot flame pattern.
Figure 24 shows an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the thermocouple. This will cause
the thermocouple to cool, which shuts the heater off.If pilot flame pattern is incorrect, as shown in
Figure 24
- turn heater off (see To Turn Off Gas to Appliance, page 20)
- see Troubleshooting pages 24 through 27.
BURNER FLAME PATTERN
Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect
burner flame pattern. If burner flame pattern is incorrect then:
- turn heater off (see To Turn Off Gas to Appliance, page 20).
- see Troubleshooting pages 24 through 27.
BURNER PRIMARY AIR
HOLES
Air is drawn into the burner through the holes in the fitting at the entrance
to the burner. These holes may become blocked with dust or lint. Periodically
inspect these holes for any blockage and clean as necessary. Blocked air holes
will create soot.
WARNING: If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide.
If the burner flame pattern shows yellow tipping, follow instructions at
bottom of this page.
Notice: Do not mistake orange flames with yellow tipping. Dirt or other
fine particles enter the heater and burn causing brief patches of orange
flame.
CARE AND MAINTENANCE
WARNING: Turn off heater and let cool before servicing.
CAUTION: You must keep control areas, burner, and circulating air
passageways of heater clean. Inspect these areas of heater before each use.
Have heater inspected yearly by a qualified service techni- cian. Heater may
need more frequent cleaning due to excessive lint from carpeting, bedding
material, pet hair, etc.
WARNING: Failure to keep the primary air opening(s) of the burner(s)
clean may result in sooting and property damage.
MAIN BURNER
Periodically inspect all burner flame holes withthe heater running. All
slotted burner flame holes should be open with yellow flame present.
All round burner flame holes should be open with a small blue flame present.
Some burner flame holes may become blocked by debris or rust, with no flame
present. If so, turn off the heater and let it cool, and remove blockage or
replace burner. Blocked burner flame holes will create soot.
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
We recommend that you clean the unit every 2,500 hours of operation or
every three months. We also recommend that you keep the burner tube and pilot
assembly clean and free of dust and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSl. Your local computer store,
hardware store, or home center may carry compressed air in a can. You can use
a vacuum cleaner in the blow position. If using compressed air in a can,
please follow the directions on the can. If you don’t follow directions on the
can, you could damage the pilot assembly.
- Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.
- Inspect burner, pilot and primary air inlet holes on injector for dust and dirt (see Figure 27).
- Blow air through the ports/slots and holes in the burner. Also clean the pilot assembly.
- Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.
- Blow air into the primary air holes on the injector holder.
- In case any large clumps of dust have now been pushed into the burner. Repeat steps 3 and 4.
ODS/PILOT
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
This can damage ODS/pilot unit.
Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to
clean.
A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly.
There is a small pilot air inlet hole about 2″ from where the pilot flame
comes out of the pilot assembly (see Figure 28). With the unit off, lightly
blow air through the air inlet hole. You may blow through a drinking straw if
compressed air is not available.
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air to clean.
Exterior
- Use a soft cloth dampened with a mild soap and water mixture.
- Wipe the cabinet to remove dust.
LOGS
- If you remove logs for cleaning, refer to Installing Logs, page 17, to properly replace logs.
- Replace log(s) if broken or chipped (dime-size or larger).
TROUBLESHOOTING
WARNING: If you smell gas:
- Shut off gas supply.
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
WARNING: Only a qualified service technician should service and repair
heater. Make sure that power is turned off before proceeding.
Turn off and let cool before servicing.
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
This can damage ODS/pilot unit.
IMPORTANT: Operating heater where impurities in air exist may create
odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and
glues, new carpet or textiles, etc., create fumes.
These fumes may mix with combustion air and create odors. These odors will
disappear over time.
Note: All troubleshooting items are listed in order of operation.
Problem | Possible Cause | Corrective Action |
---|---|---|
Using natural gas and pilot will not light. | Inlet pressure exceeds 9.5″ WC. |
Bypass pressure switch. See instructions below.
Pressure Switch
When using natural gas, there is a pressure switch that acts to turn off the
gas flow to the pilot if the inlet pressure exceeds 9.5″ WC. This is to
prevent the operation of the unit on the wrong gas (propane). If your natural
gas supply exceeds 9.5″ WC the unit will not operate.
Either contact your gas supplier to check and adjust the inlet pressure or a
qualified service technician can bypass the pressure switch.
Before attempting to bypass the pressure switch, make sure the type of gas
being used is correct. Check to make sure the connection fitting is in the
correct inlet on the regulator.
Refer to Connecting to Gas Supply, page 14.
Only a qualified installer should bypass the pressure switch. To bypass the
pressure switch locate the set screw on the regulator.
Use a small flat bladed screw driver to turn the set screw counterclockwise 2
turns. This will bypass the pressure switch function.
The entire gas delivery piping including connections inside the heater should
be leak tested by the qualified installer. After leak testing the qualified
installer should light the appliance. Refer to the correct flame pattern as
illustrated on page 21. All flame patterns
should be safely inside the product. If for any reason they are not, stop use
of the appliance and call for repairs.
Problem | Possible Cause | Corrective Action |
---|---|---|
When ignitor button is pressed in, there is no spark at ODS/pilot. | 1. Low |
battery.
2. Ignitor electrode is not connected to ignitor cable.
3. Ignitor cable is pinched or wet.
4. Ignitor electrode is positioned wrong. Ignitor lectrode is broken.
5 Broken ignitor cable.
6. Bad piezo ignitor.| 1. Replace battery.
2. Replace ignitor cable.
3. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable
dry.
4. Replace electrode.
5. Replace ignitor cable.
6. Replace piezo ignitor.
When ignitor button is pressed in there is a spark at ODS/pilot but no
ignition.| 1. Gas supply is turned off or equipment shutoff valve is closed.
2. Control knob not in PILOT position.
3. Control knob not fully pressed in while pressing ignitor button.
4. Air in gas lines (new installation or recent gas interruption).
5. ODS/pilot is clogged.
6. Incorrect inlet gas pressure or inlet regulator is damaged.
7. Depleted gas supply (propane).| 1. Turn on gas supply or open equipment
shutoff valve.
2. Turn control knob to PILOT position.
3. Fully press in control knob while pressing ignitor button.
4. Continue holding down control knob. Repeat igniting operation until air is
removed.
5. Clean ODS/pilot (see Care_ _and Maintenance , page 22) or replace
ODS/pilot assembly.
6. Check inlet gas pressure or replace inlet gas regulator.
7. Contact local propane gas company.
ODS/pilot lights but flame goes out when control knob is released.| 1.
Control knob is not fully pressed in.
2. Control knob is not pressed in long enough.
3. Equipment shutoff valve is not fully open.
4. Thermocouple connection is loose at control valve.
5. Pilot flame not touching thermocouple, which allows thermocouple to cool,
caus- ing pilot flame to go out. This problem could be caused by one or both
of the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
6. Thermocouple damaged.
7. Control valve damaged.| 1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob pressed in 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, and then tighten 1/4 turn more.
5. A) Contact local natural or propane gas company
B) Clean ODS/pilot (see Care and Maintenance , page 22) or replace ODS/
pilot assembly
6. Replace thermocouple.
7. Contact customer service.
Burner does not light after ODS/pilot is lit.| 1. Burner orifice is clogged.
2. Inlet gas pressure is too low.
3. Burner orifice diameter is too small.| 1. Clean burner orifice (see Care
and Maintenance, page 22).
2. Contact local gas supplier.
3. Replace gas train.
Delayed ignition of burner.| 1. Manifold pressure is too low.
2. Burner orifice is clogged.| 1. Contact local gas supplier.
2. Clean burner (see Care and Maintenance, page 22).
Burner backfiring during combustion.| 1. Burner orifice is clogged or
damaged.
2. Burner is damaged.
3. Gas regulator is damaged.| 1. Clean burner orifice (see Care and
Maintenance, page 22).
2. Contact customer service.
3. Replace gas train.
High yellow flame during burner combustion.| 1. Not enough air.
2. Inlet gas pressure is too low.
3. Gas regulator is defective.| 1. Check burner for dirt and debris. If
found, clean burner (see Care and Maintenance, page 22).
2. Contact local gas supplier.
3. Replace gas train.
Slight smoke or odor during initial operation.| 1. Residues from
manufacturing process.| 1. Problem will stop after a few hours of operation.
Gas odor during com- bustion.| 1. Foreign matter between control valve and
burner.
2. Gas leak. (See Warning Statement at top of page 24).| 1. Contact a
qualified service technician to remove foreign matter.
2. Locate and correct all leaks (see Checking Gas Connec- tions, page 16).
Heater produces unwanted odors.| 1. Heater is burning vapors from paint,
hair spray, glues, etc. See IMPORTANT statement, page 24.
2. Gas leak. See Warning Statement at the top of page 24.
3. Low fuel supply.| 1. Open a window to ventilate room. Stop using odor
causing products while heater is running.
2. Locate and correct all leaks (see Checking Gas Connections, page 16).
3. Refill supply tank (Propane models).
Heater produces a whis- tling noise when burner is lit.| 1. Turning control
knob to high position when burner is cold.
2. Air in gas line.
3. Air passageways on heater are blocked.
4. Dirty or partially clogged burner orifice.| 1. Turn control knob to low
position and let warm up for a minute.
2. Operate burner until air is removed from line. Have gas line checked by
local gas supplier.
3 Observe minimum installa- tion clearances (Figure 5, page 12).
4 Clean burner (see Care and Maintenance, page 22).
Heater produces a click- ing/ticking noise just after burner is lit or shut
off.| 1. Metal is expanding while heating or contracting while cooling.| 1.
This is common with most heaters. If noise is exces- sive, contact qualified
ser- vice technician.
White powder residue forming within burner box or on adjacent walls or
furniture.| 1. When heated, the vapors from furniture polish, wax, carpet
cleaners, etc., turn into white powder residue.| 1. Turn heater off when
using furniture polish, wax, carpet cleaner or similar products.
Heater shuts off in use (ODS operates).| 1. Not enough fresh air is
available.
2. Low line pressure.
3. ODS/pilot is partially clogged.| 1. Open window and/or door for
ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care and Maintenance, page 22).
Gas odor exists even when control knob is in OFF position.| 1. Gas leak. See
Warning Statement at top of page 24.
2. Control valve is defective.| 1. Locate and correct all leaks (see
Checking Gas Connec- tions, page 16).
2. Contact customer service.
Moisture/condensation noticed on windows.| 1. Not enough combustion/
ventilation air.| 1. Refer to Air for Combus- tion and Ventilation require-
ments, page 8.
PARTS
MODEL FDF400T – ZC
MODEL FDF400T- ZC
This list contains replaceable parts used in your heater. When ordering parts,
follow the instructions listed under Replacement Parts on page 30 of this
manual.
ITEM | PART # | DESCRIPTION | QTY |
---|---|---|---|
1 | 161818-01HT | Hood | 1 |
2 | 161369-01HT | Left Door Assembly | 1 |
3 | 161368-01HT | Right Door Assembly | 1 |
4 | 161822-01 | Gas Train Assembly | 1 |
5 | 161338-01 | Ignitor | 1 |
6 | 161371-00 | Log Set | 1 |
7 | 161383-01 | Blower Access Panel | 1 |
PARTS AVAILABLE – NOT SHOWN
| 161381-01| Blower Bracket| 2
| 161644-01| Hardware Package| 1
| 161371-001| Log #1| 1
| 161371-002| Log #2| 1
| 161371-003| Log #3| 1
| 161371-004| Log #4| 1
| 161371-005| Log #5| 1
| 161371-006| Log #6| 1
| 161371-007| Log #7| 1
| 161371-008| Log #8| 1
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement parts, call Customer Service toll
free at 1-855-607-6557 for referral
information.
When calling Customer Service or your dealer, have ready:
- Your name
- Your address
- Model and serial number of your heater
- How heater was malfunctioning
- Type of gas used (Propane or Natural gas)
- Purchase date
- Usually, we will ask you to return the defective part to the factory
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement part(s) call Customer Service toll
free at 1-855-607-6557 for referral
information.
When calling Customer Service have ready:
- Model number of your heater
- The replacement part number
ACCESSORIES
To purchase these heating accessories please visit our website
www.factorybuysdirect.com or give us a
call at 1-855-607-6557.
EQUIPMENT SHUTOFF VALVE
For all models. Equipment shutoff valve with 1/2″ NPT tap.
INSTALLATION KIT
SERVICE HINTS
When Gas Pressure Is Too Low
- pilot will not stay lit
- burners will have delayed ignition
- fireplace will not produce specified heat
- propane gas supply might be low (propane units only)
You may feel your gas pressure is too low. If so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact Factory Buys Direct at
1-855-607-6557.
When calling, please have your model and serial numbers of your heater ready.
WARRANTY
KEEP THIS WARRANTY
Model __
Serial No. ____
Date Purchased __
Keep receipt for warranty verification.
REGISTER YOUR PRODUCT
ATWWW.FACTORYBUYSDIRECT.COM
FACTORY BUYS DIRECT LIMITED WARRANTIES
New Products
Standard Warranty: Factory Buys Direct warrants this new product and any
parts thereof to be free from defects in material and workmanship for a period
of one (1) year from the date of first purchase from an authorized dealer
provided the product has been installed, maintained and operated in accordance
with Factory Buys Direct’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this
warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products
Limited Warranty: Factory Buys Direct warrants factory reconditioned
products and any parts thereof to be free from defects in material and
workmanship for a period 30 days from the date of first purchase from an
authorized dealer provided the product has been installed, maintained and
operated in accordance with Factory Buys Direct’s warnings and instructions.
No return will be authorized. Parts will be provided to repair the product.
Terms Common to All Warranties
The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the
manufacturer. To make a claim under this warranty, the bill of sale or other
proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased
from an authorized dealer, and only when installed by a qualified installer in
accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to
proper operating condition and an allowance for labor when provided by a
Factory Buys Direct Authorized Service Center or a provider approved by
Factory Buys Direct. Warranty parts must be obtained through authorized
dealers of this product and/or Factory Buys Direct who will provide original
factory replacement parts. Failure to use original factory replacement parts
will void this warranty.
Traveling, handling, transportation, diagnostic, material, labor and
incidental costs associated with warranty repairs, unless expressly covered by
this warranty, are not reimbursable under this warranty and are the
responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged
due to misuse, accidents, improper installation, lack of proper maintenance,
tampering or alteration(s).
This is Factory Buys Direct’s exclusive warranty, and to the full extent
allowed by law; this express warranty excludes any and all other warranties,
express or implied, written or verbal and limits the duration of any and all
implied warranties, including warranties of merchantability and fitness for a
particular purpose to one (1) year on new products and 30 days on factory
reconditioned products from the date of first purchase.
Factory Buys Direct makes no other warranties regarding this product.
Factory Buys Direct’s liability is limited to the purchase price of the
product and Factory Buys Direct shall not be liable for any other damages
whatsoever under any circumstances including direct, indirect, incidental, or
consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or
the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
Factory Buys Direct
2701 Industrial Drive
Bowling Green, KY 42101
200373-01
Rev. E 04/23
www.factorybuysdirect.com