Duluth Forge FVFLC18-1 Vent Free Gas Logs Instruction Manual

June 6, 2024
Duluth Forge

VENT-FREE GAS LOGS INSTALLATION INSTRUCTIONS
MODELS
FVFLC18-1 & FVFLC18-2
LOG CLUSTER
For Use With FDLR18-1, FLT18-1, FLM18-1-NG, and FLM18-1-LP Chassis
FVFLC18-1 Shown

Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-855-607-6557, 8:00 am – 4:30 pm CST, Monday through Friday or email contact@factorybuysdirect.com

SAVE THIS BOOK
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
This log set has been tested and approved to ANSI Z21.11.2 standard for Unvented Heaters and also complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State and local codes in some areas prohibit the use of vent-free heaters. Check your state or local codes.www.factorybuysdirect.com

INSTALLATION GUIDELINES

Qualified Installation Agency
This set should only be installed by a qualified installation agency.
Proper Log Placement
Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The illustrations in this manual show the proper position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.
Logs must fit firmly onto the burner when positioned as shown in the illustrations. Malformed logs or broken logs must be replaced.
Proper Primary Airflow into the Burner
For proper burner operation and flame appearance, the flow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This flow of air is reduced if dirt, lint or other obstructions build up around or inside the venturi. Any obstruction in the venturi tube area must be removed. The flow of air into the venturi is also reduced if the gas orifice isn’t centered in the venturi inlet and/or is not aligned with the venturi. Any misalignment of the burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans, or Logs
Installed Near Cold Air Returns
Ceiling fans or oscillating floor-type fans need to be monitored during the operation of vent-free logs. If the air blows directly into the flame causing it to impinge on the log set or firebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate flame impingement, and the floor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around a vent-free log set can cause the flame to impinge on the log and create a sooting situation.
Candles
Avoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a soot-like substance. Burning candles while the log set is operating magnifies the problem. It should be noted that candles, in general, produce soot. The amount of time burned and the number of candles burned will determine the amount of soot produced and deposited.
Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken fireplace, you must raise the floor to ensure adequate airflow and guard against sooting. Raise the fireplace floor using a noncombustible material, which is secure.
Glass Doors
Make sure that glass doors are open during all operations of the log set. The opening of the glass door frame should be the dimension used for the minimum front opening of the firebox.
Wood Burning Fireplaces
The interior of the firebox and the chimney should be cleaned and free of all creosote before installing a gas-burning log set. Creosote will soften when heated and can drop on the log set causing odors and possibly sooting.

INSTALLING LOGS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
CAUTION: After installation and periodically thereafter, check to ensure that no yellow flame comes in contact with any log. With the heater set to High, check to see if yellow flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Yellow flames contacting logs will create soot.
It is very important to install the logs exactly as instructed. Do not modify logs. Use only logs supplied with the heater.
Each log is marked with a number. This number will help you to identify the logs when installing. After installing logs, add decorative cinders around the grate base, do not place any decorative cinders on logs or burner.

  1. Place log #1 onto the shelf at the rear of the grate assembly. The features on the bottom of the log will correctly locate the log.

  2. Insert log #2 into a slot in the middle log bracket.

  3. Place log #3 into the area between the front log bracket and grate fingers.

  4. Place log #4 into notches in logs #1 and #3 at the left as shown.

  5. Place log #5 into notches in logs #1 and #3 at the right as shown.

  6. Place log #6 into notches in logs #3 and #4 as shown.

INSTALLING LOGS

MODEL FVFLC18-2

  1. Insert log #1 onto the shelf at the rear of the grate. The features at the bottom will locate the log.

  2. Insert log #2 into a slot in the middle log bracket.

  3.  Insert log #3 into the area between the front log bracket and grate fingers.

  4. Place log #4 into notches on logs #1,#2, and #3, to the left side of logs.

  5. Place log #5 over the right side of logs #1, #2, and #3. Make sure it is placed into the notches

  6. Place log #6 onto logs #2 and #4. Make sure it is placed into the notches and positioned as shown below.

  7. Place log #7 into notches on logs #3 and #5, as shown below.

PARTS

MODELS FVFLC18-1 AND FVFLC18-2

ITEM FVFLCI8-1 FVFLCI8-2 DESCRIPTION QTY
1 FVFLC18-1-1 FVFLC18-2-1 Log 1 1
2 FVFLC18-1-2 FVFLC18-2-2 Log 2 1
3 FVFLC18-1-3 FVFLC18-2-3 Log 3 1
4 FVFLC18-1-4 FVFLC18-2-4 Log 4 1
5 FVFLC18-1-5 FVFLC18-2-5 Log 5 1
6 FVFLC18-1-6 FVFLC18-2-6 Log 6 1
7 FVFLC18-2-7 Log 7 1

This list contains replaceable parts used in your heater. When ordering parts, contact authorized dealers of this product or call customer service at 1-855-607-6557. When calling has your model and serial numbers available.

200235-01C
www.factorybuysdirect.com
Factory Buys Direct.com
2701 Industrial Drive
Bowling Green, KY 42101
1-855-607-6557
200235-01
Rev. C 02/22

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals