Miele PFD 401 Unilt Under Fresh Water Dishwasher User Manual

June 1, 2024
Miele

Miele PFD 401 Unilt Under Fresh Water Dishwasher

Installation notes

For safe installation and commissioning of the dishwasher please read the installation plan, the service documentation and the operating instructions.

This installation plan includes the dimensions of the appliance, the technical data and the requirements to be met on site for the installation of the dishwasher.

Installation requirements

This dishwasher must only be installed and commissioned by the Miele Customer Service Department, a Miele authorised dealer or a suitably qualified specialist.

Installation should only be performed in accordance with valid regulations, relevant standards and health and safety codes.

Operating conditions

The following conditions must be met in order to operate the commercial dishwasher on ships:

  • The ship’s hull is longer than 24 m.
  • The list of the ship is less than 2°.
  • Any external vibration is less than 150 Hz at an amplitude of 0.35 mm.

The safe operation and correct functioning of the dishwasher cannot be guaranteed under other operating conditions.

Floor anchoring

To secure the dishwasher against tilting or movement, the two rear appliance feet must be fixed using the BBF-80 floor anchoring.

Environmental requirements

Condensate can build up in the area surrounding the dishwasher. Any furniture and fittings in the room must therefore be suitable for purpose.

Protective sheet for built-under appliances

The protective sheet supplied protects the worktop from damage caused by steam escaping when the door is opened. Fit the protective sheet above the door, underneath the worktop.

Electrical connection

All work on the electrical connection must be carried out by the Miele Customer Service Department, an authorised Miele dealer or a qualified electrician.

Plug connection The dishwasher should be connected to the electricity supply via a socket.

Hard-wired

If the dishwasher is hard-wired to the power supply, a power switch capable of disconnecting the dishwasher at all poles must be installed on site. This power switch must have a contact gap of at least 3 mm

The socket and the power switch must be accessible after the appliance has been installed. An electrical safety test must be carried out after installation and after any servicing work. The mains connection cable must be laid protected from the risk of thermal damage.

Residual current device (RCD)

For added safety, every machine should be protected by an RCD type B with a trip current of 30 mA.
The RCD must be installed so that it is easily accessible.

Equipotential bonding

There is a screw connection point for equipotential bonding at the back of the dishwasher.
Equipotential bonding should be carried out if possible on site.

Stand-alone power system

Temporary or permanent operation on an autonomous power supply system or a power supply system that is not synchronised with the mains power supply (e.g. island networks, back-up systems) is possible. A prerequisite for operation is that the power supply system complies with the specifications of EN 50160 or an equivalent standard.
The function and operation of the protective measures provided in the domestic electrical installation and in this Miele product must also be maintained in isolated operation or in operation that is not synchronised with the mains power supply, or these measures must be replaced by equivalent measures in the installation. As described, for example, in the current version of BS OHSAS 18001–2 ISO 45001.

Water connection

The dishwasher must only be connected to fully vented pipework.
A brief increase in the water pressure can damage components of the dishwasher.

Water inlet

The quality of the incoming water must correspond to the drinking water specification of the country in which the dishwasher is being operated.

The dishwasher must be connected to the water supply in strict accordance with current local and national water authority regulations.
The dishwasher can be connected to cold or hot water supplies. If hot water is not available, the two water inlet hoses (for cold and hot water) must be connected to the cold water supply via a Y-piece. The Y-piece must be connected after the non-return valve.

The stopcocks should remain accessible once the dishwasher has been installed so that the water supply can be shut off whenever the appliance is not in use.

Drain

The dishwasher drain hose should be connected to a separate on-site drainage system for the dishwasher only. If a separate connection is not available, we recommend connecting the hose to a dual-chamber siphon.
If the hose is to be fitted directly to the drainage system on site, use the hose clip supplied with the dishwasher.
The on-site connector for the drain hose can be adapted to different hose diameters. If the connector extends more than 30 mm into the drain hose, it must be shortened. Otherwise, the drain hose can become blocked.

Lay the drain hose so that it does not kink and is not being subjected to pressure or tension.
If the on-site drain connection is situated lower than the guide path for the lower basket rollers in the open door, a siphoning effect during a programme can cause the wash cabinet to empty itself of water.
In this case, lay the drain hose with a bend in it so that its highest point is at least level with the guide path for the lower basket rollers.
For AU, NZ the drain should be connected in accordance with AS/ NZS 3500.2

Connecting an external dispensing system

Up to two dispensing systems for liquid cleaning agents and rinsing agents can be connected to the back of the dishwasher. Machines with integrated dispensing systems have an external connection for rinsing agents.

Appliance dimensions

Connections

Connections on the back of the appliance

  1. Waste water
  2. Electrical connection
  3. Hot water
  4. Cold water
  5. External dispensing, power supply connection
  6. Equipotential bonding
  7. External dispensing, connection for dispenser hose

On-site connections

  1. Waste water
  2. Electrical connection
  3. Hot water
  4. Cold water
  5. External dispensing, power supply connection
  6. Equipotential bonding
  7. External dispensing, connection for dispenser hose

External dispensing

Max. delivery head 1.5 m
Length of dispenser hose, DOS module to suction lance 1.8 m
Length of dispenser hose, back of appliance to DOS module 2.8 m
Length of power cable, back of appliance to DOS module 2.8 m

Place the container on the floor next to the dishwasher or in an adjacent cabinet.
The container must not be placed on top of or above the dishwasher.

Technical data

Electrical connection

Option 1 Standard **Voltage variant ***
Voltage 3N AC 400 V AC 230 V
Frequency 50 Hz 50 Hz
Fuse rating 3 x 16 A 16 A
Plug CEE Typ-F
Mains connection cable length 1,9 m 1,9 m
Mains connection cable crosssection 5 x 2,5mm
2 3 x 1,5mm
Heater rating 8,5 kW 3,0 kW
Total rating load 8,9 kW 3,4 kW
Option 2 Standard **Voltage variant ***
Voltage 2 AC 240 V 3 AC 240 V
Frequency 60 Hz 60 Hz
--- --- ---
Fuse rating 2 x 30 A 3 x 20 A
Plug NEMA L6-30P NEMA L15-20P
Mains connection cable length 1,9 m 1,9 m
Mains connection cable cross- section 3 x AWG 10 4 x AWG 12
Heater rating 5,4 kW 5,4 kW
Total rating load 5,8 kW 5,8 kW
Option 3 Standard **Voltage variant ***
Voltage 2 AC 208 V 3 AC 208 V
Frequency 60 Hz 60 Hz
--- --- ---
Fuse rating 2 x 30 A 3 x 20 A A
Plug NEMA L6-30P Nema L15-20P
Mains connection cable length 1,9 m 1,9 m
Mains connection cable cross- section 3 x AWG 10 4 x AWG 12
Heater rating 5,4 kW 5,4 kW
Total rating load 5,8 kW 5,8 kW
  • Conversion work done by Miele Customer Service Department

Water inlet

Max. water temperature cold water 20 °C
Max. water temperature hot water 65 °C
Max. water hardness 10.71 mmol/l
Max. water hardness 60 °dH
Water connection pressure 40-1000 kPa
Flow rate 7.5 l/min
On-site threaded union (flat seal) 3/4 inch
Connection hose length 1.5 m
Connection hose extension * 1.5 m
  • Optional accessories

Drainage

Max. water temperature 70
Drain hose length 1.5 m
Max. drain hose length 4 m
Max. delivery head 1 m
Max. transient flow rate 16 l/min
Hose inner diameter (Ø) 22 mm
On-site hose sleeve (Ø x length) 22 x 30 mm

Dispensing

External dispenser pump

Max. delivery head 1.5 m
Length of dispenser hose, DOS module to suction lance approx. 1.8 m
Length of dispenser hose, back of appliance to DOS module approx. 2.8 m
Length of power cable, back of appliance to DOS module approx. 2.8 m

Dimensions

Height 820 mm
Height adjustment 60 mm
Width 598 mm
Depth 580 mm
Depth including control panel 620 mm
Depth with door open 1185 mm
Weights
Built-under appliance 64.5 kg
Max. floor load 1200 N
Emissions data
Sound power level 59 dB(A) re 1 pW
Sound pressure level in the workplace 47 dB(A)
Heat output into the room 1.44 MJ/h
Operating conditions
Ambient temperature +5 to +40 °C
Relative humidity: Up to 31 °C, maximum 80 %
Linear decreasing to 40 °C 50 %
Max. altitude above sea level up to 2000 m

Storage and transportation conditions

Ambient temperature| -20 to +75 °C
Relative humidity| 10–85 %
Air pressure| 500–1060 hPa
Min. site access dimensions including transport pallet
Height| 920 mm
Width| 670 mm
Depth| 740 mm
Weights including packaging
Built-under appliance| 74.5 kg

CUSTOMER SUPPORT

International Service Contacts
America : +1 866 694 5849
Australia, Asia, Oceania: +61 3 9764 7880
Europe, Africa, Middle East: +49 5241 89 66 877
E-mail: service@miele-marine.co
www.miele.com/marine-service
Manufacturer: Miele & Cie. KG, Carl-Miele-Straße 29, 33332 Gütersloh, Germany
Änderungen vorbehalten/2023-04-12 M.-Nr. 12 277 780 / 01