BAIcells EG8015Q-M11 LTE Turbo UE CPE User Guide

June 4, 2024
Baicells

BAIcells EG8015Q-M11 LTE Turbo UE CPE

BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-image

About This Document
This document describes the configuration of the LteTurbo CPE for EG8015Q-M11. It is a guide that how to configure the device after its installation completes.

Copyright Notice
Baicells Technologies Co., Ltd., copyrights the information in this document. No part of this document may be reproduced in any form or means without the prior written consent of Baicells Technologies Co., Ltd.

Disclaimer
The information in this document is subject to change at any time without notice. For more information, please consult with a Baicells technical engineer or the support team.

Revision Record

Date Version Description
22 July, 2022 01 Initial released.

Contact Us

| Baicells Technologies Co., Ltd.| Baicells Technologies North America, Inc.
---|---|---
| China| North America
Address| 9-10F,1stBldg.,No.81BeiqingRoad,Haidian

District,Beijing,China

| 555 Republic Dr., #200, Plano, TX 75074,

USA

Phone| 400-108-0167| +1-888-502-5585
Email| contact@Baicells.com or

support@Baicells.com

| sales_na@Baicells.com or

support_na@Baicells.com

Website| www.Baicells.com| https://na.Baicells.com

Configuration Overview

The Baicells LteTurbo CPE is loaded with its own GUI for configuring its operating parameters. You can log in to the GUI either locally through the Local Maintenance Terminal (LMT), which is an Ethernet port, or remotely via IP address. You can also use the Baicells Operations Management Console (OMC) to configure the CPE; this document, however, focuses only on using the web GUI.
The Baicells LteTurbo Outdoor User Equipment (UE) is part of a broadband wireless access system that integrates with Long-Term Evolution (LTE) backhaul networks to provide subscribers with Internet access. The UE, also referred to as Customer Premise Equipment (CPE), communicates through a wireless connection to the operator’s eNodeB’s (eNB) at cell sites located in the region. The eNBs communicate with the backhaul network.

Installation

Part & Materials
Item Qty Picture
EG8015Q-M11 unit 1 ![BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-

fig1](https://manuals.plus/wp-content/uploads/2022/08/BAIcells-EG8015Q-M11 -LTE-Turbo-UE-CPE-fig1.jpg)
Power Cable| 1| BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig2
---|---|---
PoE Power Adaptor| 1| BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig3

You will need standard tools, Ethernet cable, ground wire, and RJ-45 connectors for installing and connecting the outdoor unit.

Led

The CPE has 10 lights, divided into 6 groups according to the function: wifi signal light, lte signal light, power light, sim light, lan light, miu light (see figure below).BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig4

  • Wifi signal light
    Arc logo ,Three lights indicate wifi signal strength according to the number of lights, full light indicates strong signal; full out when not connected

  • Lte signal light
    Vertical logo ,Three lights indicate lte signal intensity according to the number of lights, full light indicates strong signal; flash when not connected

  • Power light
    The power light is bright, indicating that the power supply is normal, otherwise the power supply is abnormal

  • Sim light
    Light on -> Insert the normal SIM card; otherwise, no sim nor sim is bad.

  • Lan light
    Light on -> LAN port is connected

  • Miu light
    Reserved
    Note: The status of the lamp is meaningless during the start-on process, and wait for the start-on (5 minutes) before checking the LED status.

Login Web Client

Web Client Environmental Requirements

Table 3-1 describes the requirements on computer of the client

Table 3-1 Environmental Requirements of the Client

Item Description
CPU Above Intel Core 1GHz
Memory Above 2G RAM
Hard disk No less than 100 MB space available
Operating system
  • Microsoft: Windows XP, Windows Vista or Window
  • Mac: MacOSX10.5 or above

Screen resolution| Above 1024 x 768
Browser| Chrome 6 or higher

Connect Web Client to CPE
Connect the Ethernet interface of the computer to the WAN interface of the base station through the Ethernet cable.

Set Up Client Computer

Before logging into the Web client, the client computer’s IP address needs to be set up first so that the connection between the client and the server is possible. Take Windows 7 as an example:

  1. Click “Start>Control Panel” and later “Network and Internet” in the window that pops up.

  2. Click “View network status and tasks” and later “Local Connectivity” in the window that pops up.

  3. In “Status of Local Connectivity”, click “Properties” to see the “Properties of Local Connectivity” pop-up window.

  4. Select “Internet Protocol Version (TCP/IPV4)” and click “Properties” to see the pop-up window as Figure 3-.
    Figure 3-1 Internet Protocol Version (TCP/IPV4) Select either “Obtain an IP address automatically” or “Use the following IP address”:

    • If “Obtain an IP address automatically” selected, go directly to step 7
    • If “Use the following IP address” selected, follow step 5 ~ step 7
      NOTE: In general, if the auto obtaining fails, one needs to set up the IP address manually.
  5. Select “Use the following IP address”.

  6. Input IP address, subnet mask, and default gateway, and then click “OK”

    • IP address: 192.168.150. XXX: (recommended XXX: 100~254)
      Because the LAN interface of the base station uses the IP address of 192.168.150.1, others should avoid using this address.

    • Subnet mask: 255.255.255.0

    • Default gateway: 192.168.150.1

  7. In the command window, execute ping 192.168.150.1 and check whether the connection between the client computer and the server works or not.

Log In

  1. Open a web browser, and enter http://192.168.150.1, as shown in Figure 3-1.
    Figure 3-1 GUI Login

  2. Input user name, password, and click “Login”. The homepage is given in Figure 3-2.
    Default user/password : admin/admin
    Figure 3-2 GUI HomepageBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig9 NOTE: The information may vary by product type or software version.
    The front page shows the information as the basic information and status information of the LteTurbo CPE.The status information is dynamically refreshed, refreshed every 3 seconds.
    On the left side of the home page is the navigation pane, showing the information as Status-> Overview.On the top of home page,showing the Basic information.
    The status information area displays the WLAN connection status, rate statistics, LAN port connection status, and a list of connection devices.

Network Setting

LAN Settings

BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig10 Config Lan IP and DHCP params

WAN SettingsBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig11

  • Wan Interface: support AUTO, LTE, WIFI, and ngmwan
  • Network Mode: support NAT and L2

WLAN SettingsBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig12 Config wireless params, and wds switch.

NGMWAN SettingBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig13 Config ngmwan params

Static Routes

BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig14

LTE Setting

Connection ModeBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig15 Support AUTO, Manaual mode

Scan Mode

Support full band, fix pci, fix channel for lte scan.

APN Management

BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig16

PIN ManagementBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig17

Security Setting

ZonesBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig18 Port ForwardsBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig19 Traffic RulesBAIcells-EG8015Q-M11-LTE-Turbo-UE-
CPE-fig20Custom RulesBAIcells-EG8015Q-M11-LTE-
Turbo-UE-CPE-fig21

VPN Setting

IPSecBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig22 General VPNBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig23OpenVPNBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig24

System

NTPBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig25 AccountBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig26Dynamic DNSBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig27WEB SettingBAIcells-EG8015Q-M11-LTE-Turbo-UE-
CPE-fig28TR069BAIcells-EG8015Q-M11-LTE-Turbo-
UE-CPE-fig29FTP Auto Upgrade BAIcells-EG8015Q-M11
-LTE-Turbo-UE-CPE-fig30SNMPBAIcells-EG8015Q-M11
-LTE-Turbo-UE-CPE-fig31Restore/UpdateBAIcells-
EG8015Q-M11-LTE-Turbo-UE-CPE-fig32Ping Watchdog BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig33SASBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig34SAS SettingBAIcells-EG8015Q-M11-LTE-Turbo-UE-
CPE-fig35SAS CertificatesBAIcells-EG8015Q-M11
-LTE-Turbo-UE-CPE-fig36

DiagnosisBAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-
fig37 Reboot

BAIcells-EG8015Q-M11-LTE-Turbo-UE-CPE-fig38

Regulatory Compliance

FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Warning:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 50cm between the radiator & your body.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals