Attention to Notice

Installation Tips:

  1. Keep the product installed horizontally, otherwise it may cause the door to open and close unsmoothly.
  2. When installing, the bottom of the product and the ground must be spaced 5cm (2 inches) or more, otherwise it may lead to the product can not open and close the door smoothly (very important!!!)

Tips for Use:

  1. Do not use the power supply line other than the original to supply power to the product.
  2. Long time not use the product, need to take out the dry battery, and turn off the product power to avoid accidents
  3. When using the remote control, you need to press and hold it for 1-2S !!

Maintenance Tips:
You need to clean the gravel and other debris into the track regularly, to ensure the normal operation of the product

After-Sale Service

E-Mail : [email protected]
YouTube Channel: https://www.youtube.com/channel/UC_gcLHbzvXjKQY0p3JFz9Pw

Packaging Details

Shenan CCD-01 Automatic Chicken Coop Door 1

Installation steps

  1. horizontally on the wooden door of the chicken coop, With the automatic door in the closed state, place it then draw with a pen where the automatic door will be installed. (Note: The automatic door must be installed horizontally and higher than 2 inch above the ground !)  Then, open the automatic door and stick it on the wooden door of the chicken coop, then draw the position of the door opening with

  2. Mark the position of the screw holes for fixing the automatic door according to the position of the door hole.

  3. Open the hole according to the location of the automatic door to be installed.
    Then use a drill to drill the screw holes in the marked holes.

  4. Place the product in the corresponding position and fix it with self-tapping screws.

  5. install the solar panel in the place where the light time is long, and then insert the plug into the power hole of the automatic door.

Shenan CCD-01 Automatic Chicken Coop Door 2

Product Description

Shenan CCD-01 Automatic Chicken Coop Door 3

Icon Description Of The LCD Display

The Default Interface:

Shenan CCD-01 Automatic Chicken Coop Door 4

Work Mode

Shenan CCD-01 Automatic Chicken Coop Door 5

O: 07:00AM
The “O” is “Open”, which means the door will open automatically at 7:00AM.
C: 06:30PM
“C” means “Close”, which means it will automatically close at 6:30PM.”

As the current interface shows,
When it’s in “S” Smart Mode, the automatic door will execute the corresponding open/close command when any of the set time or light intensity is reached.

Introduction to the Record Interface

  • 85: The number of serial numbers of the record.
  • Close: Represents that this record performs a close.
  • 02:39 PM: Represents the exact time of executing the action.
  • Normal: It means the action is successful, if it fails to close the door, “Blocking” will be displayed.
  • Mode: R: Working modes of the remote control.
  • 08/10/23: represents the exact time of this record.

Work Modes of Automatic Door

  • Timer Mode
    Automatically opens or closes the door after reaching the set time.

  • Light Sensing Mode
    Automatically opens or closes the door 15 minutes after the light sensor of the automatic door detects the set light sensing value. (Default 15 minutes, can be custom adjusted in the range of 5-60 minutes).
    The default setting for opening the door is 30 and the default setting for closing the door is 20, the door will open 15 minutes after the light sensitivity exceeds 30 and close 15 minutes after it falls below 20. (30 for sunlight intensity in the morning at 6 AM. in summer and 20 for sunlight intensity in the evening at 7 PM. in summer).

  • Smart Mode
    Reaching any one of the two conditions, set time or light sensing condition, the automatic door will automatically execute the open/close command.

  • Remote control mode
    Within 100ft/30m, press the remote control “ON” to open the door, press the remote control “OFF” to close the door.

  • Manually Mode
    Press and hold the “OK” button for 3 seconds, unlock the button, press the ”Up” button to open the door, press the ”Down” button to close the door.

Humanised Auxiliary Function

  • Anti-Trap Function
    In order to avoid accidentally injuring animals, if the door touches an obstacle during the closing process, it will stop the closing action and open the door, wait for 5s and then close the door again. The action will be repeated 5 times. The automatic door stays closed from the sixth time and is alerted by flashing red LEDs and beeping tones every 15 seconds. Until the obstacle is removed, and then close the door automatically. (Note: the automatic door closing strength is light, will not pinch animals).

  • Light Sense Delay Function
    After the light condition is reached, the default delay is 15 minutes to execute the door opening and closing action (5-60 minutes range can be set).
    This function avoids the change of brightness in a short period of time, which leads to frequent opening/closing of the automatic door. (e.g. sudden darkening during the day, increase in brightness due to vehicle headlights or torches at night, etc.).

  • Time and Language Settings
    Supports setting the exact time to make the product work on time.
    Supports two language options, English and Spanish.

  • Records
    100 records of the most recent work, with details of time, dooropening and closing actions, success or failure, and mode of work.

  • Remote control pairing
    The automatic door has been paired with the remote control from the factory.
    Re-pairing just need to find the pairing in the setting menu, and then press any button of the remote control within 30S, both can complete the pairing.

  • Reset
    Restore the factory settings, it will clear all the settings, and clear all the working records.

Product Specifications

Specification

  • Closed state product size: 13.78 x 11.81 x 2.95 inch (35 x 30 x 7.5cm)
  • Product size in open condition: 16.93 x 13.78 x 2.95 (43 x 35 x 7.5cm)
  • Dimensions of automatic door opening: 10.24 x 7.87 (26 x 20cm)
  • Weight: 3 lb
  • Material: high grade ABS plastic
  • Working environment: -60℉ — 120℉ (-15℃ — 50℃)
  • Remote control band: 433 MHz

Power Supply Method
4*AA 1.5V dry battery.
Solar powered (DC 6V) + Ni-H rechargeable battery.

Common Problems In Use And Solution

  • Question : The chicken coop door can not be opened or closed smoothly.
    Answer: The upper or lower guide rail may have gravel and other foreign objects, clear the guide rail within the foreign matter can be restored to normal operation.

  • Question : The warning light flashes red, once every 15s.
    Answer:There is an obstacle in the middle, resulting in multiple triggering of the anti-clamp function, or the anti-clamp bar is deformed by accidental triggering. Remove the obstacles in the door, or make the anti-clip bar return to normal state.

  • Question : The red light flashes once in 5S, and the battery icon flashes on the screen.
    Answer:Dry battery is dead, need to replace the new dry battery.

  • Question :The remote control does not respond to controlling the coop door.
    Answer:The remote control is out of power or the key time is too short. If the remote control does not light up when pressed, replace the batteries in the remote control. If the remote control lights up when you press it, but the chicken coop door does not respond, remove the remote control in the setup interface and re-pair the remote control.

  • Question :The screen does not display the solar charging icon during daytime solar charging.
    Answer:The solar panel light angle is not good, or the connecting wire between the solar panel and the chicken coop door is not properly connected. Need to check whether the connection line between solar panel and chicken coop door is positive.

  • Question :Invalid light sensor operating mode, not opening and closing the door properly.
    Answer:Check the position of the light sensor to ensure that it is not obscured

FCC

This device complies with part 15 of the FCC
Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirement.
The device can be used in portable exposure condition without restriction

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Shenan User Manuals

Related Manuals