TECH WSR-01m P Temperature Controller Instruction Manual
- June 1, 2024
- TECH
Table of Contents
TECH WSR-01m P Temperature Controller
Specifications
- Power supply voltage: 1.2W (WSR-01m), 1.4W (WSR-02m, WSR-03m)
- Power consumption: 0.2W
- Max load: 4A (AC1)* / 200W (LED)
- Communication: Wired (TECH SBUS)
- Dimensions: 164 x 84 x 16
-
- AC1 load category: single-phase, resistive or slightly inductive AC load
Product Usage Instructions
Device Description
The device features various buttons and indicators:
- 1 – Registration button for the switch
- 2 – Registration button for the controller
- 3 – Current time
- 4 – Current temperature
- 5 – Set temperature
- 6 – Output button
- 7 – Navigation buttons
- 8 – Menu button
- 9 – Terminating resistor
- 10 – Floor sensor
Operation
To change the displayed parameter, follow these steps:
- Current temperature -> humidity -> floor temperature (after connecting the sensor)
Icons may appear indicating the need for cooling, heating, or no need for either.
Menu Navigation
If the controller is assigned to a virtual thermostat, use the buttons to
set the temperature range and enable/disable automatic lock. Confirm with the
Menu button or wait approximately 5 seconds.
Switch Buttons on WSR-03m
The outer buttons control lighting, while the middle button functions as a
programmable button. It can be used to trigger automation programmed in the
Sinum Central.
FAQ
-
How do I register the device to the Sinum system?
To register the device in the Sinum Central, activate the Identification Mode in Settings > Devices > SBUS Devices > + > Identification Mode and hold down the registration button on the device for 3-4 seconds. The corresponding device on the screen will be highlighted. -
What is the purpose of the terminating resistor (9)?
Holding down both buttons and then switching to position ON (end of line) or position 1 (middle of line) sets the terminating resistor.
www.tech-controllers.com/manuals
Made in Poland
Description
The WSR-01m / WSR-02m / WSR-03m light switch with regulator is a functional
device for controlling the room temperature, lighting or other device from
switch or via the Sinum Central device. In the Sinum Central device, the user
can program the conditions for specific automations. Communication with the
Sinum Central device is done by wire.
WSR-01m/WSR-02m/WSR-03m has a built-in temperature and humidity sensor and a
light sensor that adjusts the brightness of the button backlight to the
current brightness level in the room. Optionally, a floor temperature sensor
can be attached to the device.
- Switch registration button
- Regulator registration button
- Actual time
- Actual temperature
- Pre-set temperature
- Return button
- Navigation buttons
- Menu button
- Terminating resistor
- Floor sensor
NOTE!
- The drawings and the number of buttons may be different depending on the version you have.
- The maximum load of a single output for LED lighting is 200W.
How to register the device in the sinum system
The device should be connected to the Sinum central device using the SBUS connector and then enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the . Then briefly press the registration button 1 or 2 on the device. The regulator and the switch are treated as two individual devices and should be registered separately. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room. INFO: When registering the regulator, the humidity sensor and floor sensor (if it is connected) will also be registered automatically.
How to identify the device in the Sinum system
To identify the device in the Sinum Central, activate the Identification Mode
in the Settings > Devices > SBUS Devices > + > Identification Mode tab and
hold the registration button on the device for 3-4 seconds. The device used
will be highlighted on the screen.
Operation
Pressing button the displayed parameter changes: current temperature ->
humidity -> floor temperature (after connecting the sensor)
Heating/cooling control is possible after assigning the controller in the
Sinum Central device to a virtual thermostat. On the display may appear:
– Icon (cooling mode) – the need for cooling
– Icon (heating mode) – the need for heating
– No icon – no need for heating/cooling
Icon informs about active manual mode
Changing the preset temperature with the buttons and confirming with the Menu
button. The set temperature will be permanent.
If the regulator is assigned to a virtual thermostat, after changing the
temperature, use the to specify the time range of the set temperature [0 ÷
24h, Con (permanently) or Off (inactive change)], confirm with the Menu button
.
Button lock – pressing the Menu button will activate the function ; use the to
select „yes” or „no” (automatic lock on/ off). Confirm with the Menu button
or wait approx. 5 sec. Holding simultaneously until the padlock icon
disappears unlocks the buttons.
Controller connection – the system has a terminating connection. The
position of the regulator on the transmission line with the Sinum Central is
determined by the position of the terminating switch 9 . Set to ON position
(regulator at the end of the line) or position 1 (regulator in the middle of
the line).
EXIT and MENU button regulator functions
Pressing EXIT
- change of the displayed parameter: current temperature, air humidity, floor temperature (optional)
- exit from the menu
EXIT hold
- manual control off
Pressing MENU
- button lock option is displayed
- next menu function
- confirmation of settings
Holdig MENU
- enter the menu
WSR-03m switch butons
The outermost buttons are used to control the lighting whereas the middle
button serves as a programmable button. Using this button the user may
activate the automation which has been previously programmed in the Sinum
central device.
Menu
Hold down the Menu buttton until appears option. Change options with buttons,
confirm with Menu button. Options available:
Technical data
Switch | Regulator | |
---|---|---|
Power supply | 24V DC ±10% | 24V DC ±10% |
Max. power consumption | 1,2W (WSR-01m) |
1,4W (WSR-02m, WSR-03m)
| 0,2W
Maximum output load| 4A (AC1)* / 200W (LED)| –
Operation temperature| 5°C ÷ 50°C
Communication| Wired (TECH SBUS)
Dimensions [mm]| 164 x 84 x 16
Installation| Flush-mountable (electrical box 2 x ø60 mm)
Notes
TECH Controllers is not responsible for any damages resulting from improper
use of the system. The manufacturer reserves the right to improve devices,
update software and related documentation. The graphics are provided for
illustration purposes only and may differ slightly from the actual look. The
diagrams serve as examples. All changes are updated on an ongoing basis on the
manufacturer’s website.
Before using the device for the first time, read the following regulations
carefully. Not obeying these instructions may lead to personal injuries or
controller damage. The device should be installed by a qualified person. It is
not intended to be operated by children. It is a live electrical device. Make
sure the device is disconnected from the mains before performing any
activities involving the power supply (plugging cables, installing the device
etc.). The device is not water resistant.
EU Declaration of conformity
Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122) Hereby, we
declare under our sole responsibility that the
WSR-01m / WSR-02m / WSR-03m is compliant with Directive :
2014/35/UE • 2014/30/UE • 2009/125/WE • 2017/2102/UE
For compliance assessment, harmonized standards were used:
- PN-EN 60669-1:2018-04
- PN-EN 60669-1:2018-04/AC:2020-04E
- PN-EN 60669-2-5:2016-12
- PN-EN IEC 62368-3:2020-08
- EN IEC 63000:2018 RoHS
Wieprz, 01.12.2023
- Paweł Jura
- Janusz Master
- Prezesi firmy
The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech- controllers.com/manuals
The product may not be disposed of to household waste containers. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.
References
- controllers.com
- Intelligens fűtés-hűtés, fűtési-hűtési megoldások - TECH vezérlők gyártója | TECH vezérlők
- Sinum - TECH Controllers
- Intelligent heating, smart heating solutions - manufacturer of controllers | TECH Controllers
- Manuals - TECH Controllers
- TECH Controllers - Teplo ve Vašem domě
- TECH Controllers - Teplo vo Vašom dome
- Soluţia de acasă de economisire a energiei - producător de controlere I Tech-Controllers
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>