legrand LE13943AB Light UP Occupancy ON OFF Detector Instruction Manual

June 1, 2024
Legrand

• Light UP Occupancy ON-OFF detector
0 485 51
Instruction Manual

LE13943AB Light UP Occupancy ON OFF Detector

  • Technical documentation available in your language => Scan the QR code
  • Technische documentatie beschikbaar in jouw taal. => Scan de QR-code

legrand LE13943AB Light UP Occupancy ON OFF Detector - qr
codehttps://assets.legrand.com/pim/NP- FT-GT/S000124134.pdf

legrand LE13943AB Light UP Occupancy ON OFF Detector

| 110 – 230 V~
---|---
| 50 /60 Hz
| 2 x 1.5 mm² ou/or 1 x 2.5 mm²
| -10°C / +30°C
| PIR
| 300 lux
| 15 mn
| • Walktrough mode
| 012 m(2.5 m)
| 5.0 compatible 4.2| •Reach: 10 m
Radio| 2.4 – 2.483 GHz
•Standby consumption:| Charge/Load OFF
0,4 W| Charge/Load ON
1 W

  • P (Puissance): <100 mW
  • P (Power): <100 mW

LEGRAND, declares that radio equipment of the type Cat. no. 0 485 51 complies with Directive 2014/53/EU. The full text of the EU declaration of conformity can be found at: www.legrandoc.com

legrand LE13943AB Light UP Occupancy ON OFF Detector -
Partslegrand LE13943AB Light UP
Occupancy ON OFF Detector - Parts 2

  • 1 – Incandescent and Halogen lamps
  • 2 – Halogen lamp with separate ferromagnetic or electronic transformer
  • 3 – Fluorescent tubes
  • 4 – Compact fluorescent lamp with integrated ballast
  • 5 – Compact fluorescent lamps with transformer ferromagnetic or separate electronic
  • 6 – LED lamp
  • 7 – Contactor

legrand LE13943AB Light UP Occupancy ON OFF Detector -
wiring

  • Installation and wiring must be carried out with the power off. Please follow the Safety Instructions carefully.

legrand LE13943AB Light UP Occupancy ON OFF Detector - carried out with the
power

Wiring

• (*) This product can be controlled by:
– A wireless batteryless control (ON/OFF without dimming) Or
– A wired control (ON/OFF and dimming)
And it can control (in wireless mode) a connected outlet.

legrand LE13943AB Light UP Occupancy ON OFF Detector - A wired
control

  • The maximum distance from the control to the auxiliary input is 50 m.
  • To associate a control point and/or an outlet, Please follow the description of the procedures in the “Light Up” Technical Guide.

• Wiring
• Inputs in parallellegrand LE13943AB Light UP Occupancy ON OFF
Detector - Inputs in parallel 3

  • Master/Slave
  • The maximum distance from the control to the auxiliary input is 50 m.
  • The product is configured as Master by default.
    To change it to Slave, follow the description in the Light Up Technical Guide.

legrand LE13943AB Light UP Occupancy ON OFF Detector - Master
Slave

  • If used in “Master/Slave” mode, the push-button should only be connected to the “Master” detector.
  • The slave extends the detection area. No load will be associated with it.