minova technology MCR08M-1100 RFID Terminal Instructions

June 1, 2024
minova technology

minova technology MCR08M-1100 RFID Terminal

Specifications

  • Product Name: MCR08M-1100 RFID Terminal
  • Version: R 1.2
  • Release Date: May 02, 2023
  • Type: RFID Terminal
  • IP Protection: Not specified
  • Frequency: Not specified
  • Interface: RS485, RS232
  • Standards Supported: Not specified
  • Cards & Transponders: Not specified
  • Antenna: Included
  • Display: Included

Electrical Specifications

  • Input Charge Voltage: +12V
  • Input Current: 300 units
  • Maximum Reverse Voltage Differential Output: 40 units
  • Ambient Temperature Range: +2 to +80 units

Connector Pinout

  • Pin 1: +VIN (+12VDC) Input
  • Pin 2: GND Input
  • Pin 3: A GND NO
  • Pin 4: B RX input
  • Pin 5: GND TX output
  • Pin 6: +5V Output

Note: Inputs are optical isolated and active low. Relay outputs are dry contact with a maximum of 1.5A/24VDC.

Mounting Instructions
The wall mount part (blue kit) should be fixed onto the wall by drilling the required holes. To install the reader on the kit, insert first the upper nuts, pull the reader slightly downwards, then insert the lower nuts and finally pull the reader completely down. Optionally, you can drive the screw CCW to fix the reader.

Key Features

Type RFID/NFC Terminal
IP Protection IP65
Frequency 13.56 MHz
Interface RS485/RS232
Standards ISO14443A/B, ISO15693
Supported Cards & Transponders MIFARE® Family NTAG

I-Code

Antenna| Internal
Display| Capacitive touch

ELECTRICAL

SYMBOL PARAMETER MIN TYP MAX UNIT
VIN Input charge voltage Vin +8 +12 +36 V
IN Input current (VIN=+12V) 300 mA
VR Maximum Reverse Voltage 40 V
RS485-VOD Differential Output (RL=54Ω) +1.5 +2 +3.3 V
RS485-A/B Input Voltages -8V +13 V
RS485-A/B Output Voltages +3.3 V
RS232 Receiver Input Voltages -30 +30 V
RS232 Transmitter Output Voltages ±5 ±5.2 V
TA Ambient Temperature Range -20 +80 °C
MTBF 500.000h

F E ATURES

  • RS485/RS232 interface
  • 4.3” TFT color LCD
  • 480×272 pixel IPS
  • Capacitive touch screen
  • Full NFC support
  • FTP client for synchronization
  • 16 MB memory
  • Buzzer and real time clock
  • Waterproof design
  • +8V to +36V DC charge supply
  • -20 to +80 ºC ambient Temperature

DIMENSIONS

CONNECTOR PINOUT

Connector| Pin 1| Pin 2| Pin 3| Pin 4| Pin 5| Pin 6
---|---|---|---|---|---|---
RS485| +VIN (+12VDC)| GND| A| B| GND|
RS232| Input 2| Input 1| GND| RX input| TX output| +5V Output
Relay 1| NC| COM| NO| | |
Relay 2| NC| COM| NO| | |

The inputs are optical isolated and active low (triggered by pulling them to the GND).
The relay outputs are dry contact and max. 1.5A/24VDC.

  • COM: Common
  • NC: Normally closed
  • NO: Normally open

MOUNTING

The wall mount part (blue kit) should be fixed onto the wall by drilling the required holes. To install the reader on the kit, insert first the upper nuts, pull the reader slightly downwards, then insert the lower nuts and finally pull the reader completely down. Optionally, you can drive the screw CCW to fix the reader.

minova-technology-MCR08M-1100-RFID-Terminal- \(4\)

INPUTS & OUTPUTS

Input and relay circuitries as below.

WALL MOUNT REFERENCE

We recommend using 3mm countersunk head screws.

minova-technology-MCR08M-1100-RFID-Terminal- \(1\)

FCC Note

This unit complies with FCC RF Exposure limits for an uncontrolled environment. To comply with FCC exposure limit requirements, the device must be operated at a minimum distance of 20 cm (0.656168 feet) between the device and any person’s body.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Part 15.19 Warning Statement- (Required for all Part 15 devices)
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS

  1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
  2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

FCC Part 15.21 Warning Statement-
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals