SOUNDSTANDARD PCM-PQM Power Amplifier User Manual
- June 1, 2024
- SOUNDSTANDARD
Table of Contents
- SOUNDSTANDARD PCM-PQM Power Amplifier
- Important Safety Instruction and symbol description
- Safety instructions
- Welcome
- Unpacking
- Support and Service
- Important safety precautions
- Power & Wiring distribution
- Front Panel PQM13
- Cleaning guide of the dust filter
- Rear Panel
- Connection method
- Rear panel functions(PQM13)
- Speakon output
- Specifications
- Connection
- Troubleshooting
- Disclaimer
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SOUNDSTANDARD PCM-PQM Power Amplifier
USER MANUAL
Important Safety Instruction and symbol description
Important safety matters for power amplifier products:
1. Read these regulations, pay attention to all warnings, follow these
regulations, otherwise the product will be damaged.
2. Do not place or install the product near the water source and avoid
contact with liquid in any form. For example, do not spray liquid around the
product or place liquid containers above the product.
3. Do not place or install the product near the heat source or fire source,
and try to ensure that the ambient temperature of the product is below 35
degrees Celsius.
4. Do not install the product in small, closed, air can not be normal
convection or less flow space, to avoid the formation of hot air circulation.
5. Before powering on the product, check that the appearance of the product
is complete and that there is no distortion, damage, or blurred silkscreen.
Ensure that effective grounding protection measures are taken before powering
on the product.
6. Protect the power cable and plug to avoid deformation and wear caused by
trampling or squeezing. Check regularly to ensure that the power cable is in
proper condition for use.
7. A. Serious warning: Power plugs and device couplers are circuit cutting
devices and must be kept in stable and protected running state.
8. Power amplifier products shall be used in the following switching
sequence:
Open: start the previous equipment first– then start the power amplifier
product;
Shut down: First shut down the power amplifier product- then shut down the
preceding equipment.
9. Pay attention to the rated voltage marked on the product. Before powering
on the product, ensure that the power supply voltage meets the requirements of
the product.
10. If the input signal and connected to more than three products, it is
recommended to use the signal distributor, can avoid the input signal
distortion.
11. Do not connect the output interface of one channel of the product to the
input interface of another channel. Do not connect the output of a power
amplifier in parallel or in series to the output interface of another power
amplifier.
12. When the design system is configured with power amplifier, the product
power should be 50%-100% larger than the nominal power of the sound box under
the same impedance, and the bridge mode should be used with caution.
13. Due to the high output current to the speaker, it is recommended to use
the screw socket plug of type Nl4 speaker in accordance with the
specifications.
14. When multiple products are used, the appropriate amount of power
distribution should be calculated to ensure a qualified operating environment.
15. When repairing the product, it is forbidden to connect the probe of the
oscilloscope to the output end of the product in the bridging state, so as to
avoid damage to the product and oscilloscope.
16. This equipment is not suitable for use in places where children may be
present.
Safety instructions
| When stacking non-horizontally, the air outlet ….should be upward or be
straight to the vent.
---|---
| Input/output connection cables can not be stacked on the air outlet of the
product. They
should be tied up on both sides of the amplifier.
| The ambient temperature should be lower than 35°C while running the
amplifier
| Please verify the temperature in the cabinet when the project is debugged,
and should bekept below 35°( even though in the extreme conditions.
| The product should be grounded.
| This product is suitable for safe use below altitudes 2000m.(Only for our
company Switching Mode Power Supply equipments)
---|---
| This product is suitable for safe use of non tropical climate conditions.
| The materials which need to be technically recycled and can not be placed in
the trash can.
| The lightning bolt triangle is used to alert the user To the risk of
electric shock. Non-professional Qualified technicians do not open top or
bottom covers for maintenance
| Hot parts mark, the parts should be turned off for half an hour before
touching.
WARNING: To reduce the risk of fire or electric Shock, do not expose this apparatus To rain or moisture.
Welcome
Thank you for purchasing our products.
The PCM/PQM series power amplifier is specially designed for sound system in
large stadium, tour, theater. Please take the time to study this manual so
that you can obtain the best possible service from your amplifier.
Unpacking
Please unpack and inspect your amplifier for any damage that may have occurred during transit. Confirm the preset voltage of the power amplifier matches your local voltage rating ( Please refer to the print on the rear panel for detailed information). We also recommend that you save all packing materials so you will have them when need to return the power amplifier.
Support and Service
Please contact directly with the local SAE distributor, to get the quickest
after-sale service and technical support.
When need to contact with manufacturer, email and fax are available:
Email: support@saechina.com
FAX: +86-757-8568-8191
Important safety precautions
Our products has already taken the safe requirement in to consideration and
all the finished products have been tested under the requirement of the
government before sale.
Due to the inner dangerous high voltage and electricity, we strongly recommend
you read all instructions, warnings and cautions contained in this manual. It
will increase the chance of getting shock by the electricity if the product
falls down, recess in the appearance, soaked or there were some parts loose
internal. If there are problems above, please turn off power immediately and
send the defective units to local distributor for service.
Power & Wiring distribution
Referring to the power dissipation and power supply/AC of different product
for wiring
We suggest the users to match not less than the following wiring size
specifications, to obtain the better comprehensive properties.
The Standard Voltage : 220V –
Model | Dissipation Power | Cable size |
---|---|---|
PCM20 | 2700W | 2.5mm2 |
PQM13 | 3500W | 3.0mm2 |
Front Panel PQM13
TEMP—+ Illuminates when amplifier temperature higher than set protection
range.
MUTE—+ Illuminates when either protection circuit action.
VHF —+ Light on when comes with continues high frequency signal.
PROT—+ Illuminates when either protection circuit action.
CLIP—+ Illuminates when compressor/ limiter is protecting the amplifier from
input overload.
-5dB—+ Illuminates when output signal around -SdB than full power.
-1OdB—+ Illuminates when output signal around -lOdB than full power.
-20dB—+ Illuminates when output signal around -20dB than full power.
SIG —+ The signal light
POWER —+ Illuminates when the amplifier start.
PCM20/PCM23
TEMP—+ Illuminates when amplifier temperature higher than set protection
range.
PROT—+ Illuminates when either protection circuit action.
CLIP—+ Illuminates when compressor/ limiter is protecting the amplifier from
input overload.
-SdB—+ Illuminates when output signal around -SdB than full power.
-lOdB—+ Illuminates when output signal around -lOdB than full power.
-20dB—+ Illuminates when output signal around -20dB than full power.
SIG —+ The signal light
ON—+ Illuminates when the amplifier start.
Cleaning guide of the dust filter
The first time cleaning of the strainer mesh should be right after
installation.
Recommend to clean the strainer mesh quarterly.
Please do not run the product without the dust filter, or it makes the service
life of the product shorten.
Such condition will be considered as no warranty.
Rear Panel
Sensitivity selection should be based on audio system configuration, use occasions.Applicable to people and other requirements, due to the selection of mismatched may lead to product damage.
Connection method
- It can work from in stereo or parallel mode.
- The quality of your soldering is very important Virb.Jal welding or soldering errors. Would be likely to affect the nonnal. Use or even failure
We don’t suggest you use the amplifier under 2ohm bridge mode for a long time, it will short its normal use life or have some unnecessary failure.
Rear panel functions(PQM13)
Rear Panel
Speakon output
WARNING
- It can work from 2-16ohm in stereo or parallel mode.It can work good from 4ohm to 16ohm In bridge mode.
- We don ‘t sugges t you use the amplifier under 4ohm bridge mode or its normally use life or have some Unnecessary failure.
- The quality of your soldering is very important Virtual Would I be likely to afffect the normal Use or even a1 ure
Specifications
Model
Output power| PCM20| PQM13
---|---|---
80 stereo| 2000Wx2| 1300Wx4
40 stereo| 3500Wx2 | 2100Wx4
20 stereo| 4600Wx2 *| 2500Wx4 *
80 bridge| 7000W| 4200Wx2
40 bridge| 7800W*| 5000Wx2 **
Other Specifications
Frequency response | 20Hz-20KHz( +0/-ldB) | 20Hz-20KHz( +0/-1.SdB) |
---|---|---|
THD+N | <0.1% | SO.OS% |
S/N rate(A weighting) | 90dB | 90dB |
Slew rate | 20V/µs | lOV/µs |
Input sensitivity | 0.775/l.0V/32dB | 0.775V/1V/1.4V/ |
38dB/32dB/26dB
Input impedance(bal/unbal)| 20kO/10kO| 20kO/10kO
Voltage gain (8 ohm )| 44.2dB| 42.3dB
Output circuitry| Class I™|
Cooling| Air flow from front to rear|
Connection
Input | Balance input XLR-F, Balance output XLR-M |
---|---|
Output | Two red and black Binding posts, NL4 SPEAKON |
Function
Front panel| Front panel indicator: Working indicator,
Signal/Clip/Protection/Power on/-Sdb/-lOdb/-20db / volume control knob
---|---
Rear panel| Sensitivity selection switch, stereo/parallel/bridge/Cross-over
selection switch
Dimensions
Product Dimension(mm) | 483×456.Sx89 | 483×456.Sx89 |
---|---|---|
Packaging Dimension(mm) | 595x565x170 | 595x565x170 |
Troubleshooting
After powered without any response
Measure the outlet with a multimeter to check if there is power available and when no multimeter, you can have a test pencil. If the power supply is normal and the amplifier still no response when powered then there is something wrong with the amplifier, need professional person to check it.
No signal output
1. Frist check if the signal input is right.
A check the connect of XLR, if the 2 and 3 reverted or the ground is reliable.
Different circuitry design will have different connect way of the XLR, please
follow the 2+, 3- to soldering. It can not be judged by comparing with other
amplifiers (including other amplifiers in the same factory).
2. The signal light don’t lights up
If all the signal input is fine and the signal light don’t lights up then may
the amplifier has failure, you need to ask the professional person to check
it.
3.Signal input normal but no sound
The signal light will flash with the change of input Volume, but now sound
out, then you can check the connect of speakon if it is connect good and the
wires are connect right(some times the problem of the wires connect, check
its±l and ±2 connect), after the check above if still no sound out, please
change a speaker cable and check again. Because some times also caused by the
bad quality of the Speakon connector problem of the amplifier.
A Through experiences, it may caused by the bad connection of some plugs and
the socket.
Output sound distortion
1. After check the signal and loudspeaker they are fine and still can hear distortion when small sound, then may the amplifier has failure, need professional person to check it.
2. Some frequency band has distortion
First, check if the loudspeaker already overload, normally judge it in 95-lOSdB for higher SPL we don’t comment here. Here we just think about the failure recovery of the amplifier. If in the middle have some rupture sound and more smaller volume more obvious, then it should be crossover distortion of the amplifier and this kind of distortion is easy to confuse with the failure of loudspeaker itself. If the amplifier have problem then you should send back to the manufacture for repair.
3. Distortion is High SPL
If the sound is normal when small volume and then you need to check the limit SPL of the loudspeaker. You can listen it in suitable volume and if clip light works, then you need reduce the output. Both loudspeaker and amplifier have limit, you should use them in their limit if in very high SPL they have distortion you should take care of them and reduce the output to the right position.
The protection light blinks
When the PROT light works, the amplifier into the protection mode.
1. Maybe the temperature is too high or output short or near short and they
are not failure they can recovery after you can use it normally. But over heat
will take more time to recovery. Also when over heat happened you should check
the fan and the temperature of the install environment, if does you should
solve the problem then can use amplifier. If you think the speaker was short,
you can with a multimeter to check if the resist is lower than 2 ohm or 1 ohm
with DC(Please calibrate the multimeter to measure for accuracy because of the
small resistance).
2. If the PROT light always light up then it should be the problem of
amplifier, you should send it back to professional person for repair.
Hum in the system
1. Hum exists even when there is no signal
Please keep the amplifier away from earth wire of power supply cables, just
connect the fire wire and zero wire, no ground wire. If the hum is still
existing, it can be judged that there are some problems in the amplifier.
Please get in touch with professionals.
2. Hum exists when the system is completely connected
This is caused by the different ground voltages in difference devices in the
system, mainly happens when the power supply is under three-phase distribution
condition, each device is connected to different phase. This is not caused by
amplifier.
Solution experiences, just for reference
A. Combing the electricity, the power distribution box using the same one for
all if possible.
B. Make sure the grounding wire potential is zero and force the different
grounding wire to the same level, if the grounding wire Itself charged,
indicates that the wire may be connected with the zero line. Please solve this
problem.
C. If unavailable above, then only to disconnect the ground wires of all
devices, which helps to reduce the AC. But this is not meet the safe use of
electricity, users must know what will happen if to do in this way. We do not
recommend the floating use.
The amplifier is required maintenance in the condition below:
1. If the amplifier smokes or smells burning.
2. If the cabinet has severe indentation and deformation
3. If the amplifier are dipped into the water
4. If the internal components loosen
5. If AC breaker skips out when current increases.
Disclaimer
SAE Audio Co., Ltd. is not responsible for any damage of loudspeakers or other
equipments caused by negligence or improper installation.
SAE Audio Co., Ltd. offers 2 years limited warranty for this product.
SAE Audio Co., Ltd. Guarantees that this product has no material defect during
two years from the sales date; if the damage caused under the normal
installation and operation, SAE Audio Co., Ltd. shall change the defective
component and repair faulty product for free according to this Quality
Guarantee Agreement. However, users must send the product to our factory or
any authorized maintenance points or designated distributors, affording the
re-paid freight, together with buying proof (including customer copy of
product warranty card and payment receipt or invoice copy).
As per this Quality Guarantee Agreement, the returned product must be judged
having manufacturing defect it self after our inspection. This agreement
doesn’t apply for products with damage caused by any wrong operation
negligence, accident, inappropriate installation or products with no date code
and sequence no or damaged ones beyond recognition.
SAE Audio Co., Ltd. shall not afford responsibility for any damage caused by
accident or indirect factors. The agreement authorized you specific legal
rights.
Address:
SAE Audio Co., Ltd. After Sale Department
No.39,East,Wenjiao Road,Heshun,Lishui,Nanhai,Foshan,Guangdong,China.
PC: 528241
Tel: 0757-8560-8331
Fax:
0757-8568-8191
Email: support@saechina.com
Website: www.saeaudio.com
Manufacturer:Sae Audio Co.,LTD.
Sae reserves the right to make changes in specifications and products without
prior notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>