PurePro PROPP100 Condensate Neutralizer Instruction Manual
- June 3, 2024
- PurePro
Table of Contents
CONDENSATE NEUTRALIZER MEDIA for the PROPP40-KIT, PROPP40, PROPP100, and
PROPP-PUMP condensate neutralizers
INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
Installation Instructions
NOTE – Check with your local water authority for regulations regarding
discharge of treated condensate to the drain or sewer system.
WARNING: This product can expose you to Silica, crystalline (airborne
particles of respirable size) which is known in the state of California to
cause cancer. For more information go to
www.P65Warnings.ca.gov
Remove the old neutralizing media and rinse the capsule clean. Pour the new
neutralizing media into the capsule.
Operation
The appliance condensate will flow through the neutralizing media, raising the pH of the condensate to a level that will help prevent corrosion of the domestic drain and the public sewer system.
Maintenance
Monitor the level of the neutralizing media in the tank periodically. Check the pH level at the outlet of the neutralizing kit periodically and use a suitable pH test strip paper. The neutralizing media should be replaced when the pH level drops below the minimum level of the local water authority, or after one year, whichever comes first. For replacement media contact fwwebb.com
PurePro®, Londonderry, NH 03053
An F.W. Webb Company
fwwebb.com/purepro