Hongfa 012-1HS3AF Relay Electromagnetic Instruction Manual

June 1, 2024
Hongfa

Hongfa 012-1HS3AF Relay Electromagnetic

Product Information

Specifications

  • Model: ?=226=
  • Brand: B@C@8HIF<
  • Product Type: ?@>? EDK

Product Usage Instructions

  1. Setup
    Ensure the product is placed on a stable surface and connected to a power source.

  2. Power On
    Turn on the product by pressing the power button located on the front panel.

  3. Configuration
    Follow the on-screen instructions to configure the product settings according to your preferences.

  4. Operation

  5. Use the provided remote control or buttons on the product to navigate through menus and select options.

  6. Maintenance
    Refer to the user manual for maintenance instructions to keep the product in optimal condition.

FAQ

  • Q: How do I reset the product to factory settings?
    A: To reset the product, navigate to the settings menu and look for the reset option. Confirm the action to restore the product to its original settings.

  • Q: What should I do if the product stops responding?
    A: Try restarting the product by unplugging it from the power source, waiting for a few seconds, and then plugging it back in. If the issue persists, contact customer support for assistance.

HF115F MINIATURE HIGH POWER RELAY

Features

  • Low height: 15.7 mm
  • 16A switching capability
  • 5kV dielectric strength (between coil and contacts)
  • Contact gap: ≥0.75mm, with optional specifications
  • Creepage distance: 10mm
  • Meeting VDE 0700, 0631 reinforce insulation
  • Product in accordance to IEC 60335-1 available
  • Sockets available
  • Plastic sealed and flux proofed types available
  • UL insulation system: Class F available

CONTACT DATA

Contact arrangement 1A,1B,1C 2A,2B,2C
Contact resistance1) 100m max.(at 1A 6V C)
Contact material See ordering info.
Contact rating (Res. load) 12A/16A 250VAC 8A 250VAC
 ax. switching voltage2) 440VAC / 300V C
 ax. switching current 12A / 16A 8A
 ax. switching power 3000VA / 4000VA 2000VA
 echanical endurance 1x 107OPS
Electrical endurance
  • 1H3B type 1x 105OPS (16A 250VAC,
  • Resistive load, Room temp.,1s on 9s off) 2H4B type 5x 104OPS (8A 250VAC,
  • Resistive load, Room temp.,1s on 9s off)

Notes:

  1. The data shown above are initial values,
  2. see maximum switching power curve.

CHARACTERISTICS

Insulation resistance 1000  (at 500V C)
electric strength Between coil  contacts
Between open contacts 1000VAC 1min
Between contact sets 2500VAC 1min
Surge voltage (between coil contacts) 10kV (1.2 / 50 s)
Operate time (at nomi. volt.) 15ms max.
Release time (at nomi. volt.) 8ms max.
Temperature rise (at nomi. volt.) 55K max.
Shock resistance * Functional
 destructive 980m/s2
Vibration resistance * 10Hz to 150Hz 10g/5g
Humidity 5% to 85% RH
Ambient temperature -40     to 85
Termination PCB
Unit weight Approx. 13.5g
Construction Plastic sealed, Flux proofed

Notes:

  1. The data shown above are initial values.
  2. Index is not in relay length direction.
  3. UL insulation system: Class F, Class B.

COIL

  • Coil power
    • Approx. 400mW

COIL DATA at 23°C

 ominal Voltage V C| Pick-up Voltage V C max.1)|  rop-out Voltage V C min.1)| ax. Voltage V C 2)| Coil Resistance

---|---|---|---|---
5| 3.50| 0.5| 7.5| 62x (1 10%)
6| 4.20| 0.6| 9.0| 90x (1 10%)
9| 6.30| 0.9| 13.5| 202 x (1 10%)
12| 8.40| 1.2| 18| 360x (1 10%)
18| 12.60| 1.8| 27| 810 x (1 10%)
24| 16.80| 2.4| 36| 1440 x (1 10%)
483)| 33.60| 4.8| 72| 5760 x (1 15%)
603)| 42.00| 6.0| 90| 7500 x (1 15%)
1103)| 77.00| 11.0| 165| 25200 x (1 15%)

Notes:

  1. The data shown above are initial values.
  2. Maximum voltage refers to the maximum voltage which relay coil could endure in a short period of time.
  3. For products with rated voltage ≥ 48V, measures should be taken to prevent coil overvoltage in order to protect coil in test and application (eg. Connect diodes in parallel).

SAFETY APPROVAL RATINGS

Contact material Specifications Ratings Ambient Temperature
AgCdO HF115F .2(H )(S)4(G)(F) 8A 250VAC 70°C
HF115F  .1H(S)(1 2)(G)(F) 12A 250VAC 70°C
10A 250VAC 70°C
HF115F .1 (S)(1 2)(G)(F) 12A 250VAC 70°C

HF115F  .1H(S)3(G)(F)

| 16A 250VAC| 70°C
10A 250VAC| 70°C
9A 250VAC COS0 =0.4| 70°C
HF115F  .1 (S)3(G)(F)| 16A 250VAC| 70°C
9A 250VAC COS0 =0.4| 70°C
Agi|

HF115F  .2(H )(S)4B(G)(F)

| 5A 400VAC| 85°C
8A 250VAC| 85°C
HF115F  .1H(S)(1 2)B(G)(F)| 12A 250VAC| at 85°C
HF115F .1 (S)(1 2)B(G)(F)| 12A 250VAC| at 85°C
HF115F  .1H(S)3B(G)(F)| 16A 250VAC| at 85°C
9A 250VAC COS0 =0.4| at 70°C
HF115F .1 (S)3B(G)(F)| 16A 250VAC ( O only)| at 85°C
12A 250VAC| at 85°C
9A 250VAC COS0 =0.4 ( O only)| at 70°C
10(4)A 250VAC ( O only)| at 65°C
12(2)A 250VAC ( O only)| at 65°C
AgSnO2| HF115F .2(H )(S)4A(G)(F)| 8A 250VAC| at 85°C
HF115F  .1(H )(S)(1 2)A(G)(F)| 12A 250VAC| at 85°C
HF115F  .1H(S)3A(G)(F)| 16A 250VAC| at 85°C
9A 250VAC COS0 =0.4| at 70°C
HF115F .1 (S)3A(G)(F)| 16A 250VAC ( O only)| at 85°C
9A 250VAC COS0 =0.4 ( O only)| at 70°C

UL/CUL

Version 1 or 2 (AgCdO)

| 12A 277VAC
---|---
1/2HP 250VAC
1/3HP 125VAC

Version 1 or 2 (AgSnO2)

| 12A/ 277VAC
B300
R300
Version 1 or 2 (Ag i)| 12A 277VAC

Version 3 (AgCdO)

| 16A 277 VAC
9A 250VAC 105°C
1HP 250VAC
1/2HP 125VAC
TV-5 125VAC
Version 3 (Ag i)| 16A 277VAC
5FLA,30LRA 250VAC
Version 3 (AgSnO2)| 16A 277 VAC
---|---
1/3HP 125VAC
1/2HP 250VAC
B300
R300
Version 4 (AgCdO)| 10A 250VAC
8A 277VAC
1/2HP 250VAC
1/4HP 125VAC
Version 4 (AgSnO2)|

  • 8A 277VAC
  • 10A 250VAC
  • 1/2HP 250VAC
  • 1/4HF 250VAC

Version 4 (Ag i)| 8A 277VAC
10A 250VAC

Notes:

  1. All values unspecified are at room temperature.
  2. Only typical loads are listed above. Other load specifications can be available upon request.

ORDERING INFORMATION

Hongfa-012-1HS3AF-Relay-Electromagnetic- \(3\)

Notes:

  1. We recommend flux proofed types for a clean environment (free from contaminations like H2S, SOz, NOz, dust, etc.). We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations like H2S, SO2, NOz, dust, etc).
  2. Contact is recommend for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
  3. For gold plated type, the min. switching current and min. switching voltage is 10mA 5VDC.
  4. The customer special requirement express as special code after evaluating by Hongfa. e.g. (335) stands for product in accordance to IEC 60335-1 (GWT); (253) stands for Reflow soldering version, for 1 pole type.(AL2)indicates that the contact gap of the product is ≥0.75mm, plastic sealed typ(Only for HF 115F 2H).
  5. Two packing methods available: plastic tray package, tube package, Standard tube packing length is 616mm. Any special requirement needed, please contact us for more details.
  6. For products that should meet the explosion-proof requirements of “IEC 60079 series”, please note [Ex] after the specification while placing orders. Not all products have explosion-proof certification, so please contact us if necessary, in order to select the suitable products.

OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT

Unit: mm

Outline Dimensions

Hongfa-012-1HS3AF-Relay-Electromagnetic- \(4\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(5\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(6\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(7\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(8\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(9\)

Remark:

  1. In case of no tolerance shown in outline dimension: outline dimension ≤ 1mm, tolerance should be 0.2mm; outline dimension > 1 mm and 5mm, tolerance should be $0.3mm; outline dimension > 5mm, tolerance should be $0.4mm.
  2. The tolerance without indicating for PCB layout is always ‡0.1mm.
  3. The width of the gridding is 2.52mm.

CHARACTERISTIC CURVES

  • MAXIMUM SWITCHING POWER
  • COIL OPERATING RANGE (DC) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(10\)

Notes:   The use of a relay with an energising voltage other than the rated coil voltage may lead to reduced electrical life. An energising voltage over the abler range may damage the insulation of relay

  • ENDURANCE CURVE(Inductive)
  • Remark:
1.  **Curve:** 1H3A type
2.  **Test conditions:** NO, 85°C, 1s on 9s off, Flux proofed.
  • ENDURANCE CURVE(Resistive)
  • Remark:
1.  **Curve A** : 2H4B type Curve B: 1H1B type(or 1H2B type) Curve C: 1H3B type
2.  **Test conditions** : NO, Resistive load, 250 VAC, Flux proofed, Room temp., 1s on 9s off.

Hongfa-012-1HS3AF-Relay-Electromagnetic- \(11\)

Relay Sockets

Features

  • The insulation resistance is 1000MQ
  • Three mounting types are available : PCB, screw mounting and DIN rail mounting.
  • With finger protection device
  • Many kinds of plug-in modules are available with the function of energizing indication and wiring protection.
  • Environmental friendly product (RoHS compliant)Hongfa-012-1HS3AF-Relay-Electromagnetic- \(12\)

CHARACTERISTICS

Type|  nominal Voltage|  omental Current| Ambient| Temperature| electric Strength s.| Screw Torque| Wire Strip Length| Unit weight
---|---|---|---|---|---|---|---|---
14FF-2 -A1| 250VAC| 10A| -40| to 70| 5000VAC| | | Approx. 3g
14FF-2 -C2| 250VAC| 10A| -40| to 70| 5000VAC| 0.6 ·m| 7mm| Approx.39g
14FF-2 -C3| 250VAC| 10A| -40| to 70| 5000VAC| 0.6 ·m| 7mm| Approx.45g
14FF-2 -C4| 250VAC| 10A| -40| to 70| 5000VAC| | 9mm| Approx.42g

OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUTHongfa-012
-1HS3AF-Relay-Electromagnetic- \(13\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(14\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(15\) Hongfa-012-1HS3AF-Relay-Electromagnetic- \(16\)

Notes: * Please refer to the product datasheet if plug-in module is required

DIMENSION OF RELATED COMPONENT (AVAILABLE)

Retainer

  • 14FF-H1 (Metallic retainer)
  • 14FF-H4 (Plastic retainer)Hongfa-012-1HS3AF-Relay-Electromagnetic- \(17\)

Things to be noticed when selecting sockets:

  1.  Please choose suitable relay socket according to the actual mounting environment, relay contact poles and terminal layout. If there is any query on selection, please contact Hongfa for the technical service.
  2. Socket which can be mounted with markers is furnished with a marker; as for other related components, they should be selected separately. Please do give clear indication of the types of relay sockets and related components you choose while placing order
  3. The above is only an example of typical socket and related component type which is suitable to HF115F relay. If you have any special requirements, please contact us.
  4. Main outline dimension(L, W, H) ≥ 50mm, tolerance should be 1mm; outline dimension > 20mm and < 50mm, tolerance should be 0.5mm; outline dimension 20mm, tolerance should be 0.3mm
  5. DIN rail mounting: recommend to use standard rail 35 x 7.5 × 1mm, 35×15 x 1mm.

Disclaimer
The specification is for reference only. See to “Terminology and Guidelines” for more information. Specifications subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s responsibility to determine which product should be used only
. © Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hongfa User Manuals

Related Manuals