GE APPLIANCES AWCS05BWT Mechanical Window Air Conditioner Owner’s Manual
- June 1, 2024
- GE Appliances
Table of Contents
ROOM
AIR CONDITIONER
OWNER’S MANUAL
AWCS05BWT
AWCS05BWT Mechanical Window Air Conditioner
Write the model and serial numbers here:
Model #
Serial #
You can find the rating label on the side of the air conditioner.
GE is a trademark of the General Electric Company. Manufactured under
trademark license.
49-5000867 Rev. 0 09-23
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to
have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every
GE Appliances product, and we think you will too. Among other things,
registration of your appliance ensures that we can deliver important product
information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are
available in the Consumer Support section of this Owner’s Manual. You may also
mail in the pre-printed registration card included in the packing material.
SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING For your safety, the information in this manual must be
followed to minimize the risk of fire, electric shock or personal injury.
- Use this appliance only for its intended purpose as described in this Owner’s Manual.
- This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
- Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
- Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
- Turn the unit OFF and unplug your air conditioner before cleaning.
- For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
- If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
WARNING
Risk of Fire or Explosion. This unit contains flammable refrigerant.
Additional safety precautions must be followed.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
- Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
- Keep ventilation openings clear of obstruction.
- When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing.
- Do not drill holes in the unit.
- Maintenance, cleaning, and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants.
- GE Appliances does not support any servicing of the air conditioner.
- Dispose of air conditioner in accordance with Federal and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.
WARNING USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
- DO NOT use an extension cord with this Window Air Conditioner.
- DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from
the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug
which mates with a standard 3-prong (grounding) wall outlet to minimize the
possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is
provided on the plug case. The device should be tested on a periodic basis by
first pressing the TEST button and then the RESET button while plugged into
the outlet. If the TEST button does not trip or if the RESET button will not
stay engaged, discontinue use of the air conditioner and contact a qualified
service technician.
Have the wall outlet and circuit checked by a qualified electrician to make
sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility
and obligation to have it replaced with a properly grounded 3-prong wall
outlet.
The air conditioner should always be plugged into its own individual
electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring
circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for
specific electrical connection requirements.
READ AND SAVE THESE INSTRUCTIONS
USING THE AIR CONDITIONER
Controls
Features and appearance will vary.
Air Conditioner Controls
Controls
-
Temperature Control
This determines how much cooling is provided.
Max Cool – 10 provides the most cooling and
Min Cool – 1 provides the least.
Cooling Descriptions
For Normal Cooling—Select 4-7 on the dial with HCool r LCool selected.
For Maximum Cooling—Select 8-10 on the dial with HCool selected.
For Quieter and Nighttime Cooling—Select 1-3 on the dial with LCool selected. -
Mode Control
HCool and LCool provide cooling with different fan speeds.
HFan and LFan provide circulation and filtering without cooling.
NOTE: If you move the Temperature control from a cool setting to a fan setting or power off the unit while cooling, wait at least 3 minutes before switching back to a cool setting.
Controls
Features and appearance will vary.
CARE AND CLEANING
Care and Cleaning
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing outdoor
conditions. It must not be used when the outdoor temperature is below freezing
(32°F).
Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before
cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Air Filter
The air filter behind the front grille should be checked and cleaned at least
every 30 days or more often if necessary.
To remove:
Slide the filter from the left side of the unit. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before
replacing it. Do not clean the filter in a dishwasher.
**CAUTION** DO NOT operate the air conditioner without a filter because
dirt and lint will clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked
regularly. If they are clogged with dirt or soot, they may be professionally
cleaned.
INSTALLATION INSTRUCTIONS
Installation Instructions
Questions? Visit our Website at: GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
- IMPORTANT – Save these instructions for local inspector’s use.
- IMPORTANT – Observe all governing codes and ordinances.
- Note to Installer – Be sure to leave these instructions with the Consumer.
- Note to Consumer – Keep these instructions for future reference.
- Skill level – Installation of this appliance requires basic mechanical skills.
- Completion time – Approximately 1 hour
- We recommend that two people install this product.
- Proper installation is the responsibility of the installer.
- Product failure due to improper installation is not covered under the Warranty.
installation procedures as described in these instructions when installing this air conditioner.
ELECTRICAL REQUIREMENTS
These models require a 115/120-volt AC, 60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard.
If the wall outlet you plan to use is only a 2-prong outlet, it is your
responsibility to have it replaced with a properly grounded 3-prong wall
outlet.
CAUTION Do not, under any circumstances, cut or remove the third (ground)
prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified
electrician.
Power cord includes a current interrupter device. A test and reset button is
provided on the plug case.
The device should be tested on a periodic basis by first pressing the TEST
button and then the RESET button while plugged into the outlet. If the TEST
button does not trip or if the RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified service technician.
TOOLS YOU WILL NEED
| Phillips head screwdriver
---|---
| Drill and 1/8” drill bit
| Pencil
| Ruler or tape measure
| Level
| Scissors or knife
PARTS INCLUDED
(Appearance may vary)
1. WINDOW REQUIREMENTS
- These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
- The air conditioner can be installed without the side curtain panels if needed to fit in a narrow window. See the window opening dimensions.
- All supporting parts must be secured to firm wood, masonry or metal.
- The electrical outlet must be within reach of the power cord.
- Follow the dimensions in the table and illustration for your model.
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the
outside, and will keep it from draining properly. To adjust for this, attach a
piece of wood to the sill.
- WOOD PIECES
- WIDTH: 2
- LENGTH: Long enough to fit inside the window frame.
- THICKNESS: To determine the thickness, place than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.
3. PREPARE THE AIR CONDITIONER
A. Install the top mounting rail with 3 Type A screws
B. Slide the side curtain panels into the side panel rails.
C. Slide left and right side curtain frames into top and bottom rails. Make sure that side curtains snap into side of the frames.
4. INSTALL THE AIR CONDITIONER IN THE WINDOW
A. Measure the width of the window opening and mark the center line on the
inside window sill.
Place the unit in the window. Lower the window to hold unit in place.
B. Set the air conditioner in the window so that is centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.
C. Install the side bracket into the unit and into the window sill using two 1” wood screws provided. repeate on other side.
D. Bring the window down so that the front edge of the top mounting is in
front of the window.
Make sure that the air conditioner is level or tilting slightly to the
outside.
E. Extend the curtain panels until they fill the window. Mark the location of the holes in each corner. Use the drill and 1/8” drill bit to drill pilot holes. Use 4 type B screws to secure the side panels in place.
5. INSTALL WINDOW LOCKING BRACKET AND FOAM TOP WINDOW GASKET
Use Type B Screw to install the window lock bracket on top of the bottom
window.
CAUTION
A. To prevent broken glass or damage to windows, on vinyl or other similarly
constructed windows, attach the window locking side jamb with one Type bracket
to the window
B screw.
B. Cut the foam top window gasket to the window width.
C. Stuff the foam between the glass and the window to prevent air and insects
from getting into the room.
NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.
TROUBLESHOOTING TIPS
Troubleshooting Tips… Before you call for service
Save time and money! Review the charts on the following pages first and you
may not need to call for service.
Problem | Possible Cause | What To Do |
---|---|---|
Air conditioner does not start. | The unit is unplugged. | Make sure the air |
conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.| Check the house fuse/circuit
breaker box and replace the fuse or reset the breaker.
Power Failure.| The unit will automatically restart in the setting last used
after the power is restored.
There is a protective time delay (approximately 3 minutes) to prevent tripping
of the compressor
overload. For this reason. the unit may not start normal cooling for 3 minutes
after it is turned back on.
The current interrupter device is tripped.| Press RESET button located on the
power cord plug.
if the RESET button will not stay engaged. discontinue use of the air
conditioner and contact a qualified service technician.
Air conditioner does not cool as it should.| Indoor airflow is restricted.|
Make sure there are not curtains. blinds or furniture blocking the front of
the air conditioner.
The temp control may not be set properly.| Turn the temperature control to a
higher number.
The air filter is dirty.| Clean the filter at least every 30 days. See Care
and Cleaning section.
The room may have been hot.| When the air conditioner is first turned on. you
need to allow time for the room to cool down.
Cold air is escaping.| Check for open furnace registers and cold air returns.
Cooling coils have iced up.| See “Air conditioner freezing up below.
Air conditioner freezing up| Ice blocks the air flow and stops the air
conditioner from cooling the room.| On models with control knobs. set the mode
control at High Fan or High Cool with the Temp at 1 or 2.
Water drips outside| Hot. humid weather.| This is normal.
Water drips inside| The air conditioner is not tilted to the outside.| For
proper disposal. make sure the air conditioner slants slightly from the case
front to the rear.
Water collects in base pan| Moisture removed from air and drain into base
pan.| This is normal for a short period in areas with little humidity: normal
for a longer period in very humid areas.
Normal Operating Sounds
- You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
- You may hear the thermostat click when the compressor cycles on and off.
- Water will collect in the base pan duringhigh humidity or on rainy days. The water may overflow and drip from the outdoor sideof the unit.
- The fan may run even when the compressor does not.
- Water droplets being thrown against the outside coils can make a pinging noise. This helps cool the condenser. You can reduce this noise by removing the subbase water plug.
To ensure maximum efficiency it is recommended to check to ensure the rubber
drain plug is properly inserted.
This plug may be removed during operation to minimize water in the back of the
unit; however, removing it will lower the efficiency of your unit.
NOTE: Do not drill hole in the base pan.
LIMITED WARRANTY
Staple your receipt here.
Proof of the original purchase date is needed to make a warranty claim.
For The Period Of: | Will Replace: |
---|
One Year From the date of the
original purchase| Replacement, repair, or refund of the original retail price
for any product which fails due to a defect in materials or workmanship. If
the unit is exchanged, the replacement unit is warranted for the remainder of
your product’s original one-year warranty period. GE will, at its sole
discretion, replace the product with a product of the same or comparable
functionality and quality or refund the original retail price.
In Order to Make a Warranty Claim During Your Retailer’s Allowable Return Period:
- Properly pack your unit. We recommend using the original carton and packing materials.
- Return the product to the retail location where it was purchased.
- Include in the package a copy of the sales receipt or other evidence of date of original purchase. Also print your name and address and a description of the defect.
In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:
- Locate your original sales receipt and make a note of your model and serial number.
- Call 866-907-1655 to initiate a warranty claim.
- You will be asked to provide your name, address, receipt information, model and serial number.
- Warranty claims may require electronic or mailed-in evidence of purchase.
What Will Not Cover:
- Customer instruction. This owner’s manual provides information regarding operating instructions and user controls.
- Improper installation. If you have an installation problem, or if the air conditioner is of improper Capacity, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
- Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
- Replacement of house fuses or resetting of circuit breakers.
- Failure due to corrosion on models not corrosion- protected.
- Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
- Incidental or consequential damage caused by possible defects with this air conditioner.
- Damage caused after delivery.
EXCLUSION OF IMPLIED WARRANTIES – Your sole and exclusive remedy is
product repair as provided in this Limited Warranty. Any implied warranties,
including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by
law.
EXCLUSION OF IMPLIED WARRANTIES – Your sole and exclusive remedy is product
repair as provided in this Limited Warranty. Any implied warranties, including
the implied warranties of merchantability or fitness for a particular purpose,
are limited to one year or the shortest period allowed by law.
For US Customers: This limited warranty is extended to the original purchaser
and any succeeding owner for products purchased for home use within the USA.
If the product is located in an area where service by a GE Appliances
Authorized Servicer is not available, you may be responsible for a trip charge
or you may be required to bring the product to an Authorized GE Appliances
Service location for service. In Alaska, the limited warranty excludes the
cost of shipping or service calls to your home.
some states do not allow the exclusion or limitation of incidental or
consequential damages. This limited warranty gives you specific legal rights,
and you may also have other rights which vary from state to state. To know
what your legal rights are, consult your local or state consumer affairs
office or your state’s Attorney General.
Warrantor US:
GE Appliances, a Haier company
Louisville, KY 40225
CONSUMER SUPPORT
Consumer Support
GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances
Website 24 hours a day, any day of the year! You can also shop for more great
GE Appliances products and take advantage of all our on-line support services
designed for your convenience. In the US:
GEAppliances.com
Register Your Appliance
Register your new appliance on-line at your convenience! Timely product
registration will allow for enhanced communication and prompt service under
the terms of your warranty, should the need arise. You may also mail in the
pre-printed registration card included in the packing material. In the US:
GEAppliances.com/register
Parts and Accessories
Individuals qualified to service their own appliances can have parts or
accessories sent directly to their homes (VISA, MasterCard and Discover cards
are accepted). Order on-line today 24 hours every day.
In the US: GEApplianceparts.com or by phone at
877.959.8688 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any
user. Other servicing generally should be referred to qualified service
personnel. Caution must be exercised, since improper servicing may cause
unsafe operation.
Contact Us
If you are not satisfied with the service you receive from GE Appliances,
contact us on our Website with all the details including your phone number, or
write to: In the US: General Manager, Customer Relations | GE Appliances,
Appliance Park | Louisville, KY 40225
GEAppliances.com/contact
49-5000867 Rev. 0
Documents / Resources
| GE
APPLIANCES AWCS05BWT Mechanical Window Air
Conditioner
[pdf] Owner's Manual
AWCS05BWT Mechanical Window Air Conditioner, AWCS05BWT, Mechanical Window Air
Conditioner, Window Air Conditioner, Air Conditioner, Conditioner
---|---
References
- Appliance Parts, Accessories & Water Filters | GE Appliances
- Contact Us or Get Help with Questions | GE Appliances
- Contact Us or Get Help with Questions | GE Appliances
- GEAppliances.com/register
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>