HYDROQUIP 4kW No-Fault Hot Tub Heater Instructions

June 1, 2024
HYDROQUIP

HYDROQUIP 4kW No-Fault Hot Tub Heater

HYDROQUIP-4kW-No-Fault-Hot-Tub-Heater-PRODUCT

Product Information

Specifications:

  • Brand: SpaDepot.com
  • Model: #85-0124 Rev.01
  • Warranty: Void if product label is removed, disassembled, altered, or damaged
  • Installation: To be done by a qualified electrician or pool/spa technician

Product Usage Instructions

Installation Steps:

  1. Refer to the Heater Cross Reference Matrix to ensure the correct replacement heater (HQ part #) is being used.
  2. Do not replace heaters that are not correctly matched to avoid any issues.

Important Warnings:

  • Removing the product label, disassembling, altering, or damaging the heater voids the warranty.
  • This electrical device must be installed by a qualified professional. If unsure, contact your heater provider for assistance.

Product FAQs:

Q: Can I install the heater myself?
A: It is recommended to have the heater installed by a qualified electrician or pool/spa technician. If you are unsure of how to install the product correctly, contact your heater provider for assistance.

Q: What should I do if the heater is not heating properly?
A: Check the power source, thermostat settings, and ensure proper installation. If issues persist, contact your heater provider for troubleshooting.

WARNING! Removing the product label, disassembling, altering or damaging heater (including dry/wet firing heater) voids the product warranty

WARNING! This electrical device should be installed by an electrician or qualified pool/spa technician. If you are not qualified or do not have the knowledge to install this product correctly, stop! and contact your heater provider for assistance

STEPS FOR A SUCCESFULL INSTALLATION

  1. Using the Heater Cross Reference Matrix, confirm the number on the heater data label (HQ part #) is the correct replacement for the heater being removed from the spa Do Not Replace heaters that are not correctly matched
    HEATER CROSS-REFERENCE MATRIXHYDROQUIP-4kW-No-Fault-Hot-Tub-
Heater-1

  2. Inspect heater for shipping or other damage. Do not attempt to install a heater that’s damaged, repaired or appears to be altered in any way

  3. Turn heater temperature to off, turn off circuit breaker to spa and be certain the electrical power has been disconnected before performing this service

  4. After removing the old heater, place the new heater and secure all plumbing using existing clamps. Make sure plumbing lines are not blocked or kinked when finished

  5. A tubing kit has been provided to extend the bleed line when required on some models

  6. Re-connect the new temp sensor, high limit sensor and electrical power connections to the same location and manner as removed, making sure all connections are tightly secured. If your old heater had a pressure switch, this should be jumped on the circuit board.

  7. Re-connect bare copper bonding wire to provided ground lug on the heater support leg

  8. Fill spa and restore power. Turn on pump and test for leaks

  9. Turn heater on and verify the system operates properly

NOTE: The heater should never be allowed to operate without proper water flow. Heaters that have been dry or wet fired from improper installation, lack of water flow or alteration will not be covered by warranty

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYDROQUIP User Manuals

Related Manuals